Simulated cup/disc ratio: a tool for ophthalmologists

被引:1
|
作者
Barbosa, Carolina Pelegrini [1 ]
Angelini, Pedro Felipe [2 ]
Schor, Paulo [1 ]
Paranhos, Augusto, Jr. [1 ]
机构
[1] Univ Fed Sao Paulo UNIFESP, Escola Paulista Med, Dept Ophthalmol, Sao Paulo, Brazil
[2] Univ Sao Paulo, Escola Politecn, Sao Paulo, Brazil
关键词
Optic disc; Glaucoma/diagnosis; Optic nerve diseases/diagnosis; Diagnostic techniques; ophthalmological; Internet/utilization; Measures; OPEN-ANGLE GLAUCOMA; OPTIC-NERVE HEAD; VISUAL-FIELD; PREDICTIVE FACTORS; FIBER-LAYER; DISC; PROGRESSION; AGREEMENT; DAMAGE;
D O I
10.1590/S0004-27492010000400003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. Methods: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. Results: There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). Conclusion: Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.
引用
收藏
页码:320 / 322
页数:3
相关论文
共 50 条
  • [32] CUP/DISC RATIO IN EARLY OPEN-ANGLE GLAUCOMA
    ARMALY, MF
    DOCUMENTA OPHTHALMOLOGICA, 1969, 26 : 526 - &
  • [33] THE CUP-TO-DISC RATIO AND CENTRAL RETINAL VEIN OCCLUSION
    STRAHLMAN, ER
    QUINLAN, PM
    ENGER, C
    ELMAN, MJ
    ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (04) : 524 - 525
  • [34] The effect of photographic light brightness on cup to disc ratio grading
    Matthew J. McSoley
    Eldar Rosenfeld
    Alana Grajewski
    Ta Chen Chang
    BMC Ophthalmology, 21
  • [35] Disc Configuration as a Risk and Prognostic Factor in NAION: The Impact of Cup to Disc Ratio, Disc Diameter, and Crowding Index
    Gonzalez Martin-Moro, Julio
    Contreras, Ines
    Gutierrez-Ortiz, Consuelo
    Gomez-Sanz, Fernando
    Castro-Rebollol, Maria
    Fernandez-Hortelano, Ana
    Pilo-De-La-Fuente, Belen
    SEMINARS IN OPHTHALMOLOGY, 2019, 34 (03) : 177 - 181
  • [36] Al -based Optic Disc and Cup Segmentation Can Provide Consistent Cup -Disc Ratio (CDR) Measurements and Precise Progression Tracking
    Kinder, Scott
    McNamara, Steve
    Clark, Christopher
    Veturi, Yoga Advaith
    Dietz, Galia
    De Carlo, Talisa E.
    Kahook, Malik
    Singh, Praveer
    Kalpathy-Cramer, Jayashree
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [37] Glaucoma Screening by the Detection of Blood Vessels and Optic Cup to Disc Ratio
    Roslin, M.
    Sumathi, S.
    2016 INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING (ICCSP), VOL. 1, 2016, : 2210 - 2214
  • [38] A Semiautomatic Superpixel Based Approach to Cup-to-Disc Ratio Measurement
    Santos, Elineide
    Santos, Luis
    Veras, Rodrigo
    Frazao, Marcos
    Leite, Daniel
    2018 IEEE SYMPOSIUM ON COMPUTERS AND COMMUNICATIONS (ISCC), 2018, : 626 - 631
  • [39] Assessment of the Cup-to-Disc ratio method for Glaucoma detection.
    Joshua, Afolabi O.
    Mabuza-Hocquet, Gugulethu
    Nelwamondo, Fulufhelo, V
    2020 INTERNATIONAL SAUPEC/ROBMECH/PRASA CONFERENCE, 2020, : 405 - 409
  • [40] The impact of anthropometric and ocular parameters on optic cup-to-disc ratio
    Fukuoka, Hideki
    Tange, Chikako
    Otsuka, Rei
    Ando, Fujiko
    Shimokata, Hiroshi
    BMJ OPEN OPHTHALMOLOGY, 2016, 1 (01):