Simulated cup/disc ratio: a tool for ophthalmologists

被引:1
|
作者
Barbosa, Carolina Pelegrini [1 ]
Angelini, Pedro Felipe [2 ]
Schor, Paulo [1 ]
Paranhos, Augusto, Jr. [1 ]
机构
[1] Univ Fed Sao Paulo UNIFESP, Escola Paulista Med, Dept Ophthalmol, Sao Paulo, Brazil
[2] Univ Sao Paulo, Escola Politecn, Sao Paulo, Brazil
关键词
Optic disc; Glaucoma/diagnosis; Optic nerve diseases/diagnosis; Diagnostic techniques; ophthalmological; Internet/utilization; Measures; OPEN-ANGLE GLAUCOMA; OPTIC-NERVE HEAD; VISUAL-FIELD; PREDICTIVE FACTORS; FIBER-LAYER; DISC; PROGRESSION; AGREEMENT; DAMAGE;
D O I
10.1590/S0004-27492010000400003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. Methods: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. Results: There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). Conclusion: Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.
引用
收藏
页码:320 / 322
页数:3
相关论文
共 50 条
  • [21] CUP-DISC RATIO AND ISCHEMIC OPTIC NEUROPATHY
    DORO, S
    LESSELL, S
    ARCHIVES OF OPHTHALMOLOGY, 1985, 103 (08) : 1143 - 1144
  • [22] Effect of feedback on cup-disc ratio estimation
    Flynn, SB
    Milligan, J
    Pittenger, JB
    Realini, T
    Redens, TB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [23] Detection of Cup/Disc Ratio using Federated Learning
    Deguchi, Hodaka
    Tabuchi, Hitoshi
    Morita, Shoji
    Tanabe, Mao
    Ikuno, Yasushi
    Matsuda, Takuji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [24] Linkage and Association Analysis for Ocular Cup/Disc Ratio
    Duggal, Priya
    Wojciechowski, Robert
    Klein, Alison P.
    Cheng, Ching-Yu
    Lee, Kristine
    Klein, Ronald
    Klein, Barbara E. K.
    Bailey-Wilson, Joan E.
    GENETIC EPIDEMIOLOGY, 2009, 33 (08) : 801 - 801
  • [25] Changes in Cup-to-Disc Ratio Following Trabeculectomy
    Confait, Cassie Nabors
    Idowu, Omolola
    Moroux, Meghan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [26] AGE AND GENDER DIFFERENCES IN OPTIC DISC AREA, CUP AREA AND VERTICAL CUP-TO-DISC RATIO - THE ROTTERDAM STUDY
    RAMRATTAN, RS
    DEBRUYNE, GA
    VANREES, M
    HOFMAN, A
    DEJONG, PTVM
    VISION RESEARCH, 1995, 35 : 4135 - 4135
  • [27] Automatic Measurement of Cup-to-Disc Ratio for Retinal Images
    Zhao, Xin
    Guo, Fan
    Zou, Beiji
    Liu, Xiyao
    Zhao, Rongchang
    PATTERN RECOGNITION AND COMPUTER VISION (PRCV 2018), PT I, 2018, 11256 : 453 - 465
  • [28] The effect of photographic light brightness on cup to disc ratio grading
    McSoley, Matthew J.
    Rosenfeld, Eldar
    Grajewski, Alana
    Chang, Ta Chen
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [29] CUP/DISC RATIO - FINDINGS OF TONOMETRY AND TONOGRAPHY IN NORMAL EYE
    ARMALY, MF
    SAYEGH, RE
    ARCHIVES OF OPHTHALMOLOGY, 1969, 82 (02) : 191 - &
  • [30] 4 CLINICAL TECHNIQUES IN CUP-DISC RATIO ESTIMATION
    AUGSBURGER, A
    ALEXANDER, KL
    JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 1977, 48 (05) : 645 - 648