Assessment of shifted excitation Raman difference spectroscopy in highly fluorescent biological samples

被引:14
|
作者
Korinth, Florian [1 ,2 ,3 ,4 ]
Shaik, Tanveer Ahmed [1 ,2 ]
Popp, Jurgen [1 ,2 ,5 ,6 ]
Krafft, Christoph [1 ,2 ]
机构
[1] Leibniz Inst Photon Technol, D-07745 Jena, Germany
[2] Leibniz Res Alliance Hlth Technol, D-07745 Jena, Germany
[3] Leibniz Inst Astrophys Potsdam, D-14482 Potsdam, Germany
[4] Leibniz Res Alliance Hlth Technol, D-14482 Potsdam, Germany
[5] Friedrich Schiller Univ, Inst Phys Chem, D-07743 Jena, Germany
[6] Friedrich Schiller Univ, Abbe Ctr Photon, D-07743 Jena, Germany
关键词
MULTIPLICATIVE SIGNAL CORRECTION; CANCER-DIAGNOSIS; IN-VITRO; ALGORITHM; SPECTRA; RECONSTRUCTION; INTERFERENCE; SUPPRESSION; SUBTRACTION; REJECTION;
D O I
10.1039/d1an01376a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Shifted excitation Raman difference spectroscopy (SERDS) can be used as an instrumental baseline correction technique to retrieve Raman bands in highly fluorescent samples. Genipin (GE) cross-linked equine pericardium (EP) was used as a model system since a blue pigment is formed upon cross-linking, which results in a strong fluorescent background in the Raman spectra. EP was cross-linked with 0.25% GE solution for 0.5 h, 2 h, 4 h, 6 h, 12 h, and 24 h, and compared with corresponding untreated EP. Raman spectra were collected with three different excitation wavelengths. For the assessment of the SERDS technique, the preprocessed SERDS spectra of two excitation wavelengths (784 nm-786 nm) were compared with the mathematical baseline-corrected Raman spectra at 785 nm excitation using extended multiplicative signal correction, rubberband, the sensitive nonlinear iterative peak and polynomial fitting algorithms. Whereas each baseline correction gave poor quality spectra beyond 6 h GE crosslinking with wave-like artefacts, the SERDS technique resulted in difference spectra, that gave superior reconstructed spectra with clear collagen and resonance enhanced GE pigment bands with lower standard deviation. Key for this progress was an advanced difference optimization approach that is described here. Furthermore, the results of the SERDS technique were independent of the intensity calibration because the system transfer response was compensated by calculating the difference spectrum. We conclude that this SERDS strategy can be transferred to Raman studies on biological and non-biological samples with a strong fluorescence background at 785 nm and also shorter excitation wavelengths which benefit from more intense scattering intensities and higher quantum efficiencies of CCD detectors.
引用
收藏
页码:6760 / 6767
页数:8
相关论文
共 50 条
  • [41] Shifted-excitation Raman difference spectroscopy for improving in vivo detection of nasopharyngeal carcinoma ! br
    Lin, Jinyong
    Lin, Duo
    Qiu, Sufang
    Huang, Zufang
    Liu, Feng
    Huang, Wei
    Xu, Yuanji
    Znang, Xianzeng
    Feng, Shangyuan
    TALANTA, 2023, 257
  • [42] Advanced instantaneous shifted-excitation Raman difference spectroscopy (iSERDS) using a laser pointer
    Grueber, Klaas
    Kiefer, Johannes
    JOURNAL OF RAMAN SPECTROSCOPY, 2016, 47 (09) : 1049 - 1055
  • [43] EFFECTIVE REJECTION OF FLUORESCENCE INTERFERENCE IN RAMAN-SPECTROSCOPY USING A SHIFTED EXCITATION DIFFERENCE TECHNIQUE
    SHREVE, AP
    CHEREPY, NJ
    MATHIES, RA
    APPLIED SPECTROSCOPY, 1992, 46 (04) : 707 - 711
  • [44] Shifted excitation Raman difference spectroscopy at multiple wavelengths for in-situ meat species differentiation
    Sowoidnich, Kay
    Kronfeldt, Heinz-Detlef
    APPLIED PHYSICS B-LASERS AND OPTICS, 2012, 108 (04): : 975 - 982
  • [45] Surface-enhanced shifted excitation Raman difference spectroscopy for trace detection of fentanyl in beverages
    Ye, Jianfeng
    Wang, Sheng
    Zhang, Yujia
    Li, Boyi
    Lu, Minjian
    Qi, Xiaohua
    Wei, Haoyun
    Li, Yan
    Zou, Mingqiang
    APPLIED OPTICS, 2021, 60 (08) : 2354 - 2361
  • [46] Shifted Excitation Raman Difference Spectroscopy applied to extraterrestrial particles returned from the asteroid Itokawa
    Boettger, U.
    Maiwald, M.
    Hanke, F.
    Braune, M.
    Pavlov, S. G.
    Schroeder, S.
    Weber, I.
    Busemann, H.
    Sumpf, B.
    Traenkle, G.
    Huebers, H. -W.
    PLANETARY AND SPACE SCIENCE, 2017, 144 : 106 - 111
  • [47] Parallelized shifted-excitation Raman difference spectroscopy for fluorescence rejection in a temporary varying system
    Shimada, Rintaro
    Nakamura, Takashi
    Ozawa, Takeaki
    JOURNAL OF BIOPHOTONICS, 2019, 12 (12)
  • [48] Computational Fluorescence Suppression in Shifted Excitation Raman Spectroscopy
    Jenkins, Nia C.
    Ehrlich, Katjana
    Kufcsak, Andras
    Yerolatsitis, Stephanos
    Fernandes, Susan
    Young, Irene
    Hamilton, Katie
    Wood, Harry A. C.
    Quinn, Tom
    Young, Vikki
    Akram, Ahsan R.
    Stone, James M.
    Thomson, Robert R.
    Finlayson, Keith
    Dhaliwal, Kevin
    Seth, Sohan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (08) : 2374 - 2383
  • [49] Evaluation of Shifted Excitation Raman Difference Spectroscopy and Comparison to Computational Background Correction Methods Applied to Biochemical Raman Spectra
    Cordero, Eliana
    Korinth, Florian
    Stiebing, Clara
    Krafft, Christoph
    Schie, Iwan W.
    Popp, Juergen
    SENSORS, 2017, 17 (08):
  • [50] An intelligent background-correction algorithm for highly fluorescent samples in Raman spectroscopy
    Zhang, Zhi-Min
    Chen, Shan
    Liang, Yi-Zeng
    Liu, Zhao-Xia
    Zhang, Qi-Ming
    Ding, Li-Xia
    Ye, Fei
    Zhou, Hua
    JOURNAL OF RAMAN SPECTROSCOPY, 2010, 41 (06) : 659 - 669