Assessment of shifted excitation Raman difference spectroscopy in highly fluorescent biological samples

被引:14
|
作者
Korinth, Florian [1 ,2 ,3 ,4 ]
Shaik, Tanveer Ahmed [1 ,2 ]
Popp, Jurgen [1 ,2 ,5 ,6 ]
Krafft, Christoph [1 ,2 ]
机构
[1] Leibniz Inst Photon Technol, D-07745 Jena, Germany
[2] Leibniz Res Alliance Hlth Technol, D-07745 Jena, Germany
[3] Leibniz Inst Astrophys Potsdam, D-14482 Potsdam, Germany
[4] Leibniz Res Alliance Hlth Technol, D-14482 Potsdam, Germany
[5] Friedrich Schiller Univ, Inst Phys Chem, D-07743 Jena, Germany
[6] Friedrich Schiller Univ, Abbe Ctr Photon, D-07743 Jena, Germany
关键词
MULTIPLICATIVE SIGNAL CORRECTION; CANCER-DIAGNOSIS; IN-VITRO; ALGORITHM; SPECTRA; RECONSTRUCTION; INTERFERENCE; SUPPRESSION; SUBTRACTION; REJECTION;
D O I
10.1039/d1an01376a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Shifted excitation Raman difference spectroscopy (SERDS) can be used as an instrumental baseline correction technique to retrieve Raman bands in highly fluorescent samples. Genipin (GE) cross-linked equine pericardium (EP) was used as a model system since a blue pigment is formed upon cross-linking, which results in a strong fluorescent background in the Raman spectra. EP was cross-linked with 0.25% GE solution for 0.5 h, 2 h, 4 h, 6 h, 12 h, and 24 h, and compared with corresponding untreated EP. Raman spectra were collected with three different excitation wavelengths. For the assessment of the SERDS technique, the preprocessed SERDS spectra of two excitation wavelengths (784 nm-786 nm) were compared with the mathematical baseline-corrected Raman spectra at 785 nm excitation using extended multiplicative signal correction, rubberband, the sensitive nonlinear iterative peak and polynomial fitting algorithms. Whereas each baseline correction gave poor quality spectra beyond 6 h GE crosslinking with wave-like artefacts, the SERDS technique resulted in difference spectra, that gave superior reconstructed spectra with clear collagen and resonance enhanced GE pigment bands with lower standard deviation. Key for this progress was an advanced difference optimization approach that is described here. Furthermore, the results of the SERDS technique were independent of the intensity calibration because the system transfer response was compensated by calculating the difference spectrum. We conclude that this SERDS strategy can be transferred to Raman studies on biological and non-biological samples with a strong fluorescence background at 785 nm and also shorter excitation wavelengths which benefit from more intense scattering intensities and higher quantum efficiencies of CCD detectors.
引用
收藏
页码:6760 / 6767
页数:8
相关论文
共 50 条
  • [31] Evaluation of Shifted-Excitation Raman Difference Spectroscopy and Comparison to Ordinary Portable Raman Spectroscopy in Identification of Seized Drugs
    Zhao, Ling-yu
    Wu, Guo-ping
    Wu, Yuan-zhao
    SPECTROSCOPY, 2023, 38 (08) : 12 - 21
  • [32] Shifted Excitation Raman Difference Spectroscopy - From Diode Lasers to in-situ Applications
    Maiwald, Martin
    Sumpf, Bernd
    PLASMONICS IN BIOLOGY AND MEDICINE XV, 2018, 10509
  • [33] Comparison of fluorescence rejection methods of baseline correction and shifted excitation Raman difference spectroscopy
    Cai, Zhijian
    Zou, Wenlong
    Wu, Jianhong
    AOPC 2017: OPTICAL SPECTROSCOPY AND IMAGING, 2017, 10461
  • [34] Differentiation of lipsticks using the shifted excitation Raman difference spectroscopy supported by chemometric methods
    Zhang Jin
    Jiang Hong
    Liu Feng
    Duan Bin
    AOPC 2020: OPTICAL SPECTROSCOPY AND IMAGING; AND BIOMEDICAL OPTICS, 2020, 11566
  • [35] Breast Tumor Analysis Using Shifted-Excitation Raman Difference Spectroscopy (SERDS)
    Gebrekidan, Medhanie Tesfay
    Erber, Ramona
    Hartmann, Arndt
    Fasching, Peter A.
    Emons, Julius
    Beckmann, Mathias W.
    Braeuer, Andreas
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2018, 17
  • [36] Shifted Excitation Raman Difference Spectroscopy - a potential tool for outdoor measurements in precision agriculture
    Maiwald, Martin
    Mueller, Andre
    Selbeck, Joern
    Kaethner, Jana
    Zude, Manuela
    Fleury, Domenique
    Sumpf, Bernd
    Erbert, Goetz
    Traenkle, Guenther
    SENSING FOR AGRICULTURE AND FOOD QUALITY AND SAFETY VII, 2015, 9488
  • [37] Microsystem Light Source at 488 nm for Shifted Excitation Resonance Raman Difference Spectroscopy
    Maiwald, Martin
    Schmidt, Heinar
    Sumpf, Bernd
    Guether, Reiner
    Erbert, Goetz
    Kronfeldt, Heinz-Detlef
    Traenkle, Guenther
    APPLIED SPECTROSCOPY, 2009, 63 (11) : 1283 - 1287
  • [38] Fluorescence background suppression in Raman spectroscopy using combined Kerr gated and shifted excitation Raman difference techniques
    Matousek, P
    Towrie, M
    Parker, AW
    JOURNAL OF RAMAN SPECTROSCOPY, 2002, 33 (04) : 238 - 242
  • [39] Shifted Excitation Resonance Raman Difference Spectroscopy using a Microsystem Light Source at 488 nm
    Maiwald, M.
    Sowoidnich, K.
    Schmidt, H.
    Sumpf, B.
    Erbert, G.
    Kronfeldt, H. -D.
    ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES VII, 2010, 7673
  • [40] Shifted excitation Raman difference spectroscopy at multiple wavelengths for in-situ meat species differentiation
    Kay Sowoidnich
    Heinz-Detlef Kronfeldt
    Applied Physics B, 2012, 108 : 975 - 982