Assessment of shifted excitation Raman difference spectroscopy in highly fluorescent biological samples

被引:14
|
作者
Korinth, Florian [1 ,2 ,3 ,4 ]
Shaik, Tanveer Ahmed [1 ,2 ]
Popp, Jurgen [1 ,2 ,5 ,6 ]
Krafft, Christoph [1 ,2 ]
机构
[1] Leibniz Inst Photon Technol, D-07745 Jena, Germany
[2] Leibniz Res Alliance Hlth Technol, D-07745 Jena, Germany
[3] Leibniz Inst Astrophys Potsdam, D-14482 Potsdam, Germany
[4] Leibniz Res Alliance Hlth Technol, D-14482 Potsdam, Germany
[5] Friedrich Schiller Univ, Inst Phys Chem, D-07743 Jena, Germany
[6] Friedrich Schiller Univ, Abbe Ctr Photon, D-07743 Jena, Germany
关键词
MULTIPLICATIVE SIGNAL CORRECTION; CANCER-DIAGNOSIS; IN-VITRO; ALGORITHM; SPECTRA; RECONSTRUCTION; INTERFERENCE; SUPPRESSION; SUBTRACTION; REJECTION;
D O I
10.1039/d1an01376a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Shifted excitation Raman difference spectroscopy (SERDS) can be used as an instrumental baseline correction technique to retrieve Raman bands in highly fluorescent samples. Genipin (GE) cross-linked equine pericardium (EP) was used as a model system since a blue pigment is formed upon cross-linking, which results in a strong fluorescent background in the Raman spectra. EP was cross-linked with 0.25% GE solution for 0.5 h, 2 h, 4 h, 6 h, 12 h, and 24 h, and compared with corresponding untreated EP. Raman spectra were collected with three different excitation wavelengths. For the assessment of the SERDS technique, the preprocessed SERDS spectra of two excitation wavelengths (784 nm-786 nm) were compared with the mathematical baseline-corrected Raman spectra at 785 nm excitation using extended multiplicative signal correction, rubberband, the sensitive nonlinear iterative peak and polynomial fitting algorithms. Whereas each baseline correction gave poor quality spectra beyond 6 h GE crosslinking with wave-like artefacts, the SERDS technique resulted in difference spectra, that gave superior reconstructed spectra with clear collagen and resonance enhanced GE pigment bands with lower standard deviation. Key for this progress was an advanced difference optimization approach that is described here. Furthermore, the results of the SERDS technique were independent of the intensity calibration because the system transfer response was compensated by calculating the difference spectrum. We conclude that this SERDS strategy can be transferred to Raman studies on biological and non-biological samples with a strong fluorescence background at 785 nm and also shorter excitation wavelengths which benefit from more intense scattering intensities and higher quantum efficiencies of CCD detectors.
引用
下载
收藏
页码:6760 / 6767
页数:8
相关论文
共 50 条
  • [21] Improving Raman Spectroscopy using Diode Lasers at 785 nm for Shifted Excitation Raman Difference Spectroscopy
    Maiwald, M.
    Sumpf, B.
    PLASMONICS IN BIOLOGY AND MEDICINE XVII, 2020, 11257
  • [22] Sequentially Shifted Excitation Raman Spectroscopy
    Cooper, John B.
    Wise, Kent L.
    Jones, Richard W.
    Marshall, Sarah
    SPECTROSCOPY, 2015, : 24 - 28
  • [23] Sequentially Shifted Excitation Raman Spectroscopy
    Cooper, John B.
    Wise, Kent L.
    Jones, Richard W.
    Marshall, Sarah
    SPECTROSCOPY, 2014, 29 (11) : 38 - 42
  • [24] Sequentially shifted excitation Raman spectroscopy
    Cooper, John B.
    Wise, Kent L.
    Jones, Richard W.
    Marshall, Sarah
    Spectroscopy (Santa Monica), 2014, 29 (10) : 38 - 42
  • [25] Microsystem 671 nm light source for shifted excitation Raman difference spectroscopy
    Maiwald, Martin
    Schmidt, Heinar
    Sumpf, Bernd
    Erbert, Goetz
    Kronfeldt, Heinz-Detlef
    Traenkle, Guenther
    APPLIED OPTICS, 2009, 48 (15) : 2789 - 2792
  • [26] A portable shifted excitation Raman difference spectroscopy system: device and field demonstration
    Maiwald, Martin
    Mueller, Andre
    Sumpf, Bernd
    Traenkle, Guenther
    JOURNAL OF RAMAN SPECTROSCOPY, 2016, 47 (10) : 1180 - 1184
  • [27] Shifted excitation Raman difference spectroscopy as enabling technique for the analysis of animal feedstuff
    Sowoidnich, Kay
    Oster, Michael
    Wimmers, Klaus
    Maiwald, Martin
    Sumpf, Bernd
    JOURNAL OF RAMAN SPECTROSCOPY, 2021, 52 (08) : 1418 - 1427
  • [28] Microsystem light source at 671 nm for shifted excitation Raman difference spectroscopy
    Maiwald, M.
    Schmidt, H.
    Sumpf, B.
    Kronfeldt, H. -D.
    Erbert, G.
    ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES VI, 2009, 7312
  • [29] Portable shifted excitation Raman difference spectroscopy for on-site soil analysis
    Maiwald, Martin
    Sowoidnich, Kay
    Sumpf, Bernd
    JOURNAL OF RAMAN SPECTROSCOPY, 2022, 53 (09) : 1560 - 1570
  • [30] Cohfocal micro-Raman spectroscopy of single biological cells using optical trapping and shifted excitation difference techniques
    Xie, CG
    Li, YQ
    JOURNAL OF APPLIED PHYSICS, 2003, 93 (05) : 2982 - 2986