Photopeak Efficiency and Coincidence Summing Factors for HPGe Detectors Using Bulk Sources

被引:0
|
作者
Alharshan, Gharam A. [1 ]
机构
[1] Princess Nourah Bint Abdulrahman Univ, Riyadh, Saudi Arabia
来源
HEALTH PHYSICS | 2020年 / 118卷 / 04期
关键词
gamma radiation; radiation; ionizing; radiation safety; spectrometry; gamma; ABSOLUTE-PEAK-EFFICIENCY; GAMMA-RAY DETECTORS; CALIBRATION; GE(LI);
D O I
10.1097/HP.0000000000001143
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the field of gamma-ray spectroscopy with high-purity germanium detectors, used to measure the activity when the sample to be measured has low radioactivity, volumetric sources are widely used. To determine the sample activity, the full-energy peak efficiency is needed. Bulk sources are very common for low-level radioactivity measurements in activation analysis and environmental samples. The main problem with these measurements is that coincidence effects are large for close source-detector geometries. Ignoring these effects can lead to an error typically of a factor of 2 in the determination of Co-60 and Y-88 activity, which was used in this work in the calibration process. Extensive experimental readings have been carried out, and bulk gamma aqueous sources containing several radionuclides covering the energy range from 60 to 1,840 keV were used. By comparison, the experimental (present work) and theoretical (published) full-energy peak efficiency values are in good agreement; the overall percentage error is less than 6%.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 50 条
  • [1] Statistical analysis of absolute photopeak efficiency of clover HPGe detectors
    Dey, P.
    Palit, R.
    Das, Biswajit
    Kundu, A.
    Malik, Vishal
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1072
  • [2] Numerical expressions for the computation of coincidence-summing correction factors in γ-ray spectrometry with HPGe detectors
    Rizzo, S.
    Tomarchio, E.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 555 - 560
  • [3] Study of true coincidence summing effects on FEP efficiency of HPGe detectors during decay measurements at HIRFL
    Zheng, Peng-Song
    Shi, Fu-Rong
    Dutt, Sunil
    Zhang, Ya-Ling
    Zhang, Yan-Shi
    Wang, Wei
    Li, Guang-Shun
    Wang, Si-Cheng
    Yang, Hao-Ran
    He, Jin-Qi
    Ma, Peng-Cong
    Gada, Jilehu
    Ma, Xin
    Zeng, Fan-Fei
    Huang, Hao
    Gao, Chen-Sheng
    Wang, Jian-Guo
    NUCLEAR SCIENCE AND TECHNIQUES, 2025, 36 (05)
  • [4] Efficiency simulation and coincidence-summing correction for HPGe detector
    Zhang, Ruiqin
    Li, Qi
    Fan, Yuanqing
    Zhao, Yungang
    Zhang, Xinjun
    Jia, Huaimao
    Niu, Yazhou
    Li, Ruiying
    Wang, Shilian
    He Jishu/Nuclear Techniques, 2024, 47 (11):
  • [5] Simplified methods for coincidence summing corrections in HPGe efficiency calibration
    Mauring, Alexander
    Drefvelin, Jon
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2161 - 2163
  • [6] HPGe detector photopeak efficiency calculation including self-absorption and coincidence corrections for cylindrical sources using compact analytical expressions
    Abbas, MI
    Selim, YS
    Bassiouni, M
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 429 - 431
  • [7] Calculation of Coincidence Summing Correction Factors for an HPGe detector using GEANT4
    Giubrone, G.
    Ortiz, J.
    Gallardo, S.
    Martorell, S.
    Bas, M. C.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2016, 158 : 114 - 118
  • [8] HPGe detector photopeak efficiency calculation including self-absorption and coincidence corrections for Marinelli beaker sources using compact analytical expressions
    Abbas, MI
    APPLIED RADIATION AND ISOTOPES, 2001, 54 (05) : 761 - 768
  • [9] Correction equations of coincidence summing using 75Se radionuclide in the efficiency of HpGe detector
    Lee, Y
    Park, S
    Choi, K
    Horiguchi, T
    Inoue, H
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 242 (01) : 105 - 110
  • [10] Correction equations of coincidence summing using75Se radionuclide in the efficiency of HpGe detector
    Y. Lee
    S. Park
    K. Choi
    T. Horiguchi
    H. Inoue
    Journal of Radioanalytical and Nuclear Chemistry, 1999, 242 : 105 - 110