Simplified methods for coincidence summing corrections in HPGe efficiency calibration

被引:3
|
作者
Mauring, Alexander [1 ]
Drefvelin, Jon [1 ]
机构
[1] Norwegian Radiat Protect Author, N-1332 Osteras, Norway
关键词
Gamma spectrometry; Coincidence summing; HPGe detectors; n-Type; Detector efficiency; GAMMA-RAY SPECTROMETRY; DECAY;
D O I
10.1016/j.apradiso.2012.02.086
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Simple and practical coincidence summing corrections for n-type HPGe detectors are presented for the common calibration nuclides Co-57 and Co-60 using a defined "virtual peak" and accounting for the summing of gamma photons with x-rays having energies up to 40 key (Y-88 and Ce-139). These corrections make it possible to easily and effectively establish peak and total efficiency curves suitable for subsequent summing corrections in routine gamma spectrometry analyses. Experimental verification of the methods shows excellent agreement for measurements of different reference solutions. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2161 / 2163
页数:3
相关论文
共 50 条
  • [1] Total efficiency calibration for coincidence-summing corrections
    Lepy, Marie-Christine
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 284 - 287
  • [2] True coincidence summing corrections for an extended energy range HPGe detector
    Venegas-Argumede, Y.
    Montero-Cabrera, M. E.
    RADIATION PHYSICS: XI INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 2015, 1671
  • [3] Efficiency simulation and coincidence-summing correction for HPGe detector
    Zhang, Ruiqin
    Li, Qi
    Fan, Yuanqing
    Zhao, Yungang
    Zhang, Xinjun
    Jia, Huaimao
    Niu, Yazhou
    Li, Ruiying
    Wang, Shilian
    He Jishu/Nuclear Techniques, 2024, 47 (11):
  • [4] Corrections of HPGe detector efficiency curve due to true coincidence summing by program EFFTRAN and by Monte Carlo simulations
    Knezevic, J.
    Mrdja, D.
    Hansman, J.
    Bikit, K.
    Forkapic, S.
    Bikit, I.
    Velimirovic, D.
    Kuzmanovic, P.
    APPLIED RADIATION AND ISOTOPES, 2022, 189
  • [5] Efficiency transfer and coincidence summing corrections for γ-ray spectrometry
    Piton, F
    Lépy, MC
    Bé, MM
    Plagnard, J
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 791 - 795
  • [6] Coincidence summing corrections in HPGe gammaray spectrometry for Marinelli-beakers geometry using peak to total (P/T) calibration
    Ababneh, Anas M.
    Eyadeh, Molham M.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2015, 8 (03) : 323 - 327
  • [7] Photopeak Efficiency and Coincidence Summing Factors for HPGe Detectors Using Bulk Sources
    Alharshan, Gharam A.
    HEALTH PHYSICS, 2020, 118 (04): : 396 - 401
  • [8] Coincidence summing corrections for a clover detector
    Agarwal, Chhavi
    Danu, L. S.
    Gathibandhe, M.
    Goswami, A.
    Biswas, D. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 763 : 240 - 247
  • [9] Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level gamma-ray spectrometry using well-type HPGe detectors
    Laborie, JM
    Le Petit, G
    Abt, D
    Girard, M
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (1-2) : 57 - 62
  • [10] Intercomparison of methods for coincidence summing corrections in gamma-ray spectrometry
    Lepy, M. -C.
    Altzitzoglou, T.
    Anagnostakis, M. J.
    Arnold, D.
    Capogni, M.
    Ceccatelli, A.
    De Felice, P.
    Dersch, R.
    Dryak, P.
    Fazio, A.
    Ferreux, L.
    Guardati, M.
    Han, J. B.
    Hurtado, S.
    Karfopoulos, K. L.
    Klemola, S.
    Kovar, P.
    Lee, K. B.
    Ocone, R.
    Ott, O.
    Sima, O.
    Sudar, S.
    Svec, A.
    Chau Van Tao
    Tran Thien Thanh
    Vidmar, T.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1407 - 1412