Photopeak Efficiency and Coincidence Summing Factors for HPGe Detectors Using Bulk Sources

被引:0
|
作者
Alharshan, Gharam A. [1 ]
机构
[1] Princess Nourah Bint Abdulrahman Univ, Riyadh, Saudi Arabia
来源
HEALTH PHYSICS | 2020年 / 118卷 / 04期
关键词
gamma radiation; radiation; ionizing; radiation safety; spectrometry; gamma; ABSOLUTE-PEAK-EFFICIENCY; GAMMA-RAY DETECTORS; CALIBRATION; GE(LI);
D O I
10.1097/HP.0000000000001143
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the field of gamma-ray spectroscopy with high-purity germanium detectors, used to measure the activity when the sample to be measured has low radioactivity, volumetric sources are widely used. To determine the sample activity, the full-energy peak efficiency is needed. Bulk sources are very common for low-level radioactivity measurements in activation analysis and environmental samples. The main problem with these measurements is that coincidence effects are large for close source-detector geometries. Ignoring these effects can lead to an error typically of a factor of 2 in the determination of Co-60 and Y-88 activity, which was used in this work in the calibration process. Extensive experimental readings have been carried out, and bulk gamma aqueous sources containing several radionuclides covering the energy range from 60 to 1,840 keV were used. By comparison, the experimental (present work) and theoretical (published) full-energy peak efficiency values are in good agreement; the overall percentage error is less than 6%.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 50 条
  • [31] Coincidence summing corrections in HPGe gammaray spectrometry for Marinelli-beakers geometry using peak to total (P/T) calibration
    Ababneh, Anas M.
    Eyadeh, Molham M.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2015, 8 (03) : 323 - 327
  • [32] Coincidence Summing Factor Calculation for Volumetric γ-ray Sources Using Geant4 Simulation
    Aloraini, Dalal Abdullah
    Elsafi, Mohamed
    Almuqrin, Aljawhara H.
    Sayyed, M. I.
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2022, 2022
  • [33] ON DETERMINATION OF DISINTEGRATION RATES BY COINCIDENCE METHOD USING HIGH EFFICIENCY DETECTORS
    HAYWARD, RW
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1961, 12 (1-2): : 148 - &
  • [34] HPGe detector absolute full-energy peak efficiency calibration including coincidence correction for circular disc sources
    Abbas, Mahmoud I.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (18) : 3952 - 3958
  • [35] Total versus effective total efficiency in the computation of coincidence summing corrections in gamma-ray spectrometry of volume sources
    Arnold, D
    Sima, O
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2001, 248 (02) : 365 - 370
  • [36] Total versus effective total efficiency in the computation of coincidence summing corrections in gamma-ray spectrometry of volume sources
    D. Arnold
    O. Sima
    Journal of Radioanalytical and Nuclear Chemistry, 2001, 248 : 365 - 370
  • [37] Geant4 Tracks of NaI Cubic Detector Peak Efficiency, Including Coincidence Summing Correction for Rectangular Sources
    Elsafi, Mohamed
    Alzahrani, Jamila S.
    Abbas, Mahmoud I.
    Gouda, Mona M.
    Thabet, Abouzeid A.
    Badawi, Mohamed S.
    El-Khatib, Ahmed M.
    NUCLEAR SCIENCE AND ENGINEERING, 2021, 195 (09) : 1008 - 1016
  • [38] Coincidence summing corrections using PENELOPE/PENNUC Monte Carlo code for volume sources of different densities
    Salpadimos, N.
    Karfopoulos, K.
    Potiriadis, C.
    Seimenis, I.
    APPLIED RADIATION AND ISOTOPES, 2023, 192
  • [39] Investigation of the effect of copper contact pin on efficiency in HPGe detectors using Monte Carlo method
    Uyar, E.
    Aksoy, G.
    Unlu, H.
    Bolukdemir, M. H.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (11)
  • [40] Evaluation of HPGe detector efficiency for point sources using virtual point detector model
    Mohammadi, M. A.
    Abdi, M. R.
    Kamali, M.
    Mostajaboddavati, M.
    Zare, M. R.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (02) : 521 - 526