The Accuracy of Smart Devices for Measuring Physical Activity in Daily Life: Validation Study

被引:44
|
作者
Degroote, Laurent [1 ,2 ]
De Bourdeaudhuij, Ilse [1 ]
Verloigne, Maite [1 ]
Poppe, Louise [1 ,2 ]
Crombez, Geert [2 ]
机构
[1] Univ Ghent, Phys Act & Hlth, Dept Movement & Sports Sci, Watersportlaan 2, B-9000 Ghent, Belgium
[2] Univ Ghent, Hlth Psychol, Dept Expt Clin & Hlth Psychol, Ghent, Belgium
来源
JMIR MHEALTH AND UHEALTH | 2018年 / 6卷 / 12期
关键词
physical activity; fitness trackes; accelerometry; ACTIVITY QUESTIONNAIRE; ACTIVITY MONITORS; SELF-EFFICACY; VALIDITY; HEALTH; FITNESS; ADULTS; RELIABILITY; CALIBRATION; PEDOMETER;
D O I
10.2196/10972
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Wearables for monitoring physical activity (PA) are increasingly popular. These devices are not only used by consumers to monitor their own levels of PA but also by researchers to track the behavior of large samples. Consequently, it is important to explore how accurately PA can be tracked via these devices. Objectives: The aim of this study was, therefore, to investigate convergent validity of 3 Android Wear smartwatches-Polar M600 (Polar Electro Oy, Kempele, Finland), Huawei Watch (Huawei Technologies Co, Ltd, Shenzhen, Guangdong, China), Asus Zenwatch3 (AsusTek Computer Inc, Taipei, Taiwan)-and Fitbit Charge with an ActiGraph accelerometer for measuring steps and moderate to vigorous physical activity (MVPA) on both a day level and 15-min level. Methods: A free-living protocol was used in which 36 adults engaged in usual daily activities over 2 days while wearing 2 different wearables on the nondominant wrist and an ActiGraph GT3X+ accelerometer on the hip. Validity was evaluated on both levels by comparing each wearable with the ActiGraph GT3X+ accelerometer using correlations and Bland-Altman plots in IBM SPSS 24.0. Results: On a day level, all devices showed strong correlations (Spearman r=.757-.892) and good agreement (interclass correlation coefficient, ICC=.695-.885) for measuring steps, whereas moderate correlations (Spearman r=.557-.577) and low agreement (ICC=.377-.660) for measuring MVPA. Bland-Altman revealed a systematic overestimation of the wearables for measuring steps but a variation between over-and undercounting of MVPA. On a 15-min level, all devices showed strong correlations (Spearman r=.752-.917) and good agreement (ICC=.792-.887) for measuring steps, whereas weak correlations (Spearman r=.116-.208) and low agreement (ICC=.461-.577) for measuring MVPA. Bland-Altman revealed a systematic overestimation of the wearables for steps but under- or overestimation for MVPA depending on the device. Conclusions: In sum, all 4 consumer-level devices can be considered accurate step counters in free-living conditions. This study, however, provides evidence of systematic bias for all devices in measurement of MVPA. The results on a 15-min level also indicate that these devices are not sufficiently accurate to provide correct real-time feedback.
引用
下载
收藏
页数:16
相关论文
共 50 条
  • [21] Objective evaluation of physical activity pattern using smart devices
    Monika Šimaitytė
    Andrius Petrėnas
    Julija Kravčenko
    Eleni Kaldoudi
    Vaidotas Marozas
    Scientific Reports, 9
  • [22] Objective evaluation of physical activity pattern using smart devices
    Simaityte, Monika
    Petrenas, Andrius
    Kravcenko, Julija
    Kaldoudi, Eleni
    Marozas, Vaidotas
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [23] Daily life activity in patients with left ventricular assist devices
    Granegger, Marcus
    Schloeglhofer, Thomas
    Ober, Henrik
    Zimpfer, Daniel
    Schima, Heinrich
    Moscato, Francesco
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2016, 39 (01): : 22 - 27
  • [24] Measuring Physical Activity With Implanted Cardiac Devices: A Systematic Review
    Rosman, Lindsey
    Lampert, Rachel
    Sears, Samuel F.
    Burg, Matthew M.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (11):
  • [25] Accuracy of 12 Wearable Devices for Estimating Physical Activity Energy Expenditure Using a Metabolic Chamber and the Doubly Labeled Water Method: Validation Study
    Murakami, Haruka
    Kawakami, Ryoko
    Nakae, Satoshi
    Yamada, Yosuke
    Nakata, Yoshio
    Ohkawara, Kazunori
    Sasai, Hiroyuki
    Ishikawa-Takata, Kazuko
    Tanaka, Shigeho
    Miyachi, Motohiko
    JMIR MHEALTH AND UHEALTH, 2019, 7 (08):
  • [26] Oxygen therapy devices and portable ventilators for improved physical activity in daily life in patients with chronic respiratory disease
    Furlanetto, Karina Couto
    Pitta, Fabio
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (02) : 103 - 115
  • [27] Assessing Student Knowledge and Incorporation of Smart Technology Into Daily Physical Activity
    Martin, Nicole J.
    Schmick, Ayla M.
    PHYSICAL EDUCATOR-US, 2018, 75 (03): : 327 - 340
  • [28] Ecological monitoring of physical activity, emotions and daily life activities in schizophrenia: the DiAPAson study
    Zarbo, Cristina
    Rota, Matteo
    Calza, Stefano
    Crouter, Scott E.
    Ekelund, Ulf
    Barlati, Stefano
    Bussi, Riccardo
    Clerici, Massimo
    Placenti, Roberto
    Paulillo, Giuseppina
    Pogliaghi, Silvia
    Rocchetti, Matteo
    Ruggeri, Mirella
    Starace, Fabrizio
    Zanolini, Stefano
    Zamparini, Manuel
    de Girolamo, Giovanni
    BMJ MENTAL HEALTH, 2023, 26 (01):
  • [29] Drive for thinness, affect regulation and physical activity in eating disorders: A daily life study
    Vansteelandt, Kristof
    Rijrnen, Frank
    Pieters, Guido
    Probst, Michel
    Vanderlinden, Johan
    BEHAVIOUR RESEARCH AND THERAPY, 2007, 45 (08) : 1717 - 1734
  • [30] A Time-Lagged Momentary Assessment Study on Daily Life Physical Activity and Affect
    Wichers, Marieke
    Peeters, Frenk
    Rutten, Bart P. F.
    Jacobs, Nele
    Derom, Catherine
    Thiery, Evert
    Delespaul, Philippe
    van Os, Jim
    HEALTH PSYCHOLOGY, 2012, 31 (02) : 135 - 144