Accuracy of 12 Wearable Devices for Estimating Physical Activity Energy Expenditure Using a Metabolic Chamber and the Doubly Labeled Water Method: Validation Study

被引:53
|
作者
Murakami, Haruka [1 ,2 ]
Kawakami, Ryoko [1 ,2 ,3 ]
Nakae, Satoshi [4 ,5 ,6 ]
Yamada, Yosuke [7 ,8 ]
Nakata, Yoshio [9 ]
Ohkawara, Kazunori [10 ]
Sasai, Hiroyuki [11 ]
Ishikawa-Takata, Kazuko [4 ,5 ]
Tanaka, Shigeho [4 ,5 ]
Miyachi, Motohiko [1 ,2 ]
机构
[1] Natl Inst Biomed Innovat, Dept Phys Act Res, Tokyo, Japan
[2] Natl Inst Hlth & Nutr, Dept Phys Act Res, Tokyo, Japan
[3] Waseda Univ, Fac Sport Sci, Tokorozawa, Saitama, Japan
[4] Natl Inst Biomed Innovat, Dept Nutr & Metab, Tokyo, Japan
[5] Natl Inst Hlth & Nutr, Dept Nutr & Metab, Tokyo, Japan
[6] Osaka Univ, Grad Sch Engn Sci, Osaka, Japan
[7] Natl Inst Biomed Innovat, Sect Hlth Longev Res, Tokyo, Japan
[8] Natl Inst Hlth & Nutr, Sect Hlth Longev Res, Tokyo, Japan
[9] Univ Tsukuba, Fac Hlth & Sport Sci, Ibaraki, Japan
[10] Univ Electrocommun, Grad Sch Informat & Engn, Tokyo, Japan
[11] Univ Tokyo, Grad Sch Arts & Sci, Tokyo, Japan
来源
JMIR MHEALTH AND UHEALTH | 2019年 / 7卷 / 08期
关键词
physical activity; accelerometry; energy expenditure; indirect calorimetry; doubly labeled water; ACTIVITY MONITORS; CONSUMER; VALIDITY; ADULTS; HISTORY; HEALTH; SIT;
D O I
10.2196/13938
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Self-monitoring using certain types of pedometers and accelerometers has been reported to be effective for promoting and maintaining physical activity (PA). However, the validity of estimating the level of PA or PA energy expenditure (PAEE) for general consumers using wearable devices has not been sufficiently established. Objective: We examined the validity of 12 wearable devices for determining PAEE during 1 standardized day in a metabolic chamber and 15 free-living days using the doubly labeled water (DLW) method. Methods: A total of 19 healthy adults aged 21 to 50 years (9 men and 10 women) participated in this study. They followed a standardized PA protocol in a metabolic chamber for an entire day while simultaneously wearing 12 wearable devices: 5 devices on the waist, 5 on the wrist, and 2 placed in the pocket. In addition, they spent their daily lives wearing 12 wearable devices under free-living conditions while being subjected to the DLW method for 15 days. The PAEE criterion was calculated by subtracting the basal metabolic rate measured by the metabolic chamber and 0.1 x total energy expenditure (TEE) from lEE. The TEE was obtained by the metabolic chamber and DLW methods. The PAEE values of wearable devices were also extracted or calculated from each mobile phone app or website. The Dunnett test and Pearson and Spearman correlation coefficients were used to examine the variables estimated by wearable devices. Results: On the standardized day, the PAEE estimated using the metabolic chamber (PAEEcha) was 528.8 +/- 149.4 kcal/day. The PAEEs of all devices except the TANITA AM-160 (513.8 +/- 135.0 kcal/day; P>.05), SUZUKEN Lifecorder EX (519.3 +/- 89.3 kcal/day; P>.05), and Panasonic Actimarker (545.9 +/- 141.7 kcal/day; P>.05) were significantly different from the PAEEcha. None of the devices was correlated with PAEEcha according to both Pearson (r=-.13 to .37) and Spearman (rho=-.25 to .46) correlation tests. During the 15 free-living days, the PAEE estimated by DLW (PAEEdlw) was 728.0 +/- 162.7 kcal/day. PAEE values of all devices except the Omron Active style Pro (716.2 +/- 159.0 kcal/day; P>.05) and Omron CaloriScan (707.5 +/- 172.7 kcal/day; P>.05) were significantly underestimated. Only 2 devices, the Omron Active style Pro (r=.46; P=.045) and Panasonic Actimarker (r=.48; P=.04), had significant positive correlations with PAEEdlw according to Pearson tests. In addition, 3 devices, the TANITA AM-160 (rho=.50; P=.03), Omron CaloriScan (rho=.48; P=.04), and Omron Active style Pro (rho=.48; P=.04), could be ranked in PAEEdlw. Conclusions: Most wearable devices do not provide comparable PAEE estimates when using gold standard methods during 1 standardized day or 15 free-living days. Continuous development and evaluations of these wearable devices are needed for better estimations of PAEE.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Accuracy of Wearable Devices for Estimating Total Energy Expenditure: Comparison With Metabolic Chamber and Doubly Labeled Water Method
    Murakami, Haruka
    Kawakami, Ryoko
    Nakae, Satoshi
    Nakata, Yoshio
    Ishikawa-Takata, Kazuko
    Tanaka, Shigeho
    Miyachi, Motohiko
    JAMA INTERNAL MEDICINE, 2016, 176 (05) : 702 - 703
  • [2] Simultaneous Validation of Seven Physical Activity Questionnaires Used in Japanese Cohorts for Estimating Energy Expenditure: A Doubly Labeled Water Study
    Sasai, Hiroyuki
    Nakata, Yoshio
    Murakami, Haruka
    Kawakami, Ryoko
    Nakae, Satoshi
    Tanaka, Shigeho
    Ishikawa-Takata, Kazuko
    Yamada, Yosuke
    Miyachi, Motohiko
    JOURNAL OF EPIDEMIOLOGY, 2018, 28 (10) : 437 - 442
  • [3] Estimating energy expenditure from the Minnesota Leisure Time Physical Activity and Tecumseh Occupational Activity questionnaires - a doubly labeled water validation
    Conway, JM
    Irwin, ML
    Ainsworth, BE
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 2002, 55 (04) : 392 - 399
  • [4] Methods to Estimate Energy Expenditure, Physical Activity, and Sedentary Time in Pregnant Women: A Validation Study Using Doubly Labeled Water
    Alomairah, Saud Abdulaziz
    de Place Knudsen, Signe
    Roland, Caroline Borup
    Hergel, Ida-Marie
    Molsted, Stig
    Clausen, Tine D.
    Lokkegaard, Ellen
    Bendix, Jane M.
    Maddison, Ralph
    Lof, Marie
    Larsen, Jakob Eg
    van Hall, Gerrit
    Stallknecht, Bente
    JOURNAL FOR THE MEASUREMENT OF PHYSICAL BEHAVIOUR, 2023, 6 (01) : 88 - 98
  • [5] VALIDATION OF DOUBLY LABELED WATER METHOD FOR ENERGY-EXPENDITURE IN POSTSURGICAL INFANTS
    JONES, PJH
    WINTHROP, AL
    SCHOELLER, DA
    SWYER, PR
    FILLER, RM
    SMITH, JM
    HEIM, T
    FEDERATION PROCEEDINGS, 1986, 45 (04) : 817 - 817
  • [6] Validation of accelerometer placement to capture energy expenditure using doubly labeled water
    Dougherty, Ryan J.
    Liu, Fangyu
    Etzkorn, Lacey
    Wanigatunga, Amal A.
    Walter, Peter J.
    Knuth, Nicolas D.
    Schrack, Jennifer A.
    Ferrucci, Luigi
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2022, : 1045 - 1049
  • [7] Measuring energy expenditure in narcolepsy using doubly labeled water and respiration chamber calorimetry
    Donjacour, Claire E. H. M.
    Gool, Jari K.
    Schoffelen, Paul F.
    Wouters, Loek
    Overeem, Sebastiaan
    Lammers, Gert Jan
    Pijl, Hanno
    Westerterp, Klaas R.
    SLEEP, 2024,
  • [8] Total Energy Expenditure in Children Assessed by Doubly Labeled Water and Physical Activity Questionnaire
    Wong, Stephen H. S.
    Sung, Rita Y. T.
    Ho, C. S.
    Chen, Y. J.
    Yu, C. W.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S567 - S567
  • [9] Heart rate monitoring as a field method for estimating energy expenditure as evaluated by the doubly labeled water method
    Kashiwazaki, H
    JOURNAL OF NUTRITIONAL SCIENCE AND VITAMINOLOGY, 1999, 45 (01) : 79 - 94
  • [10] Validity of the physical activity scale for the elderly (PASE): According to energy expenditure assessed by the doubly labeled water method
    Schuit, AJ
    Schouten, EG
    Westerterp, KR
    Saris, WHM
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 1997, 50 (05) : 541 - 546