Accuracy of 12 Wearable Devices for Estimating Physical Activity Energy Expenditure Using a Metabolic Chamber and the Doubly Labeled Water Method: Validation Study

被引:53
|
作者
Murakami, Haruka [1 ,2 ]
Kawakami, Ryoko [1 ,2 ,3 ]
Nakae, Satoshi [4 ,5 ,6 ]
Yamada, Yosuke [7 ,8 ]
Nakata, Yoshio [9 ]
Ohkawara, Kazunori [10 ]
Sasai, Hiroyuki [11 ]
Ishikawa-Takata, Kazuko [4 ,5 ]
Tanaka, Shigeho [4 ,5 ]
Miyachi, Motohiko [1 ,2 ]
机构
[1] Natl Inst Biomed Innovat, Dept Phys Act Res, Tokyo, Japan
[2] Natl Inst Hlth & Nutr, Dept Phys Act Res, Tokyo, Japan
[3] Waseda Univ, Fac Sport Sci, Tokorozawa, Saitama, Japan
[4] Natl Inst Biomed Innovat, Dept Nutr & Metab, Tokyo, Japan
[5] Natl Inst Hlth & Nutr, Dept Nutr & Metab, Tokyo, Japan
[6] Osaka Univ, Grad Sch Engn Sci, Osaka, Japan
[7] Natl Inst Biomed Innovat, Sect Hlth Longev Res, Tokyo, Japan
[8] Natl Inst Hlth & Nutr, Sect Hlth Longev Res, Tokyo, Japan
[9] Univ Tsukuba, Fac Hlth & Sport Sci, Ibaraki, Japan
[10] Univ Electrocommun, Grad Sch Informat & Engn, Tokyo, Japan
[11] Univ Tokyo, Grad Sch Arts & Sci, Tokyo, Japan
来源
JMIR MHEALTH AND UHEALTH | 2019年 / 7卷 / 08期
关键词
physical activity; accelerometry; energy expenditure; indirect calorimetry; doubly labeled water; ACTIVITY MONITORS; CONSUMER; VALIDITY; ADULTS; HISTORY; HEALTH; SIT;
D O I
10.2196/13938
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Self-monitoring using certain types of pedometers and accelerometers has been reported to be effective for promoting and maintaining physical activity (PA). However, the validity of estimating the level of PA or PA energy expenditure (PAEE) for general consumers using wearable devices has not been sufficiently established. Objective: We examined the validity of 12 wearable devices for determining PAEE during 1 standardized day in a metabolic chamber and 15 free-living days using the doubly labeled water (DLW) method. Methods: A total of 19 healthy adults aged 21 to 50 years (9 men and 10 women) participated in this study. They followed a standardized PA protocol in a metabolic chamber for an entire day while simultaneously wearing 12 wearable devices: 5 devices on the waist, 5 on the wrist, and 2 placed in the pocket. In addition, they spent their daily lives wearing 12 wearable devices under free-living conditions while being subjected to the DLW method for 15 days. The PAEE criterion was calculated by subtracting the basal metabolic rate measured by the metabolic chamber and 0.1 x total energy expenditure (TEE) from lEE. The TEE was obtained by the metabolic chamber and DLW methods. The PAEE values of wearable devices were also extracted or calculated from each mobile phone app or website. The Dunnett test and Pearson and Spearman correlation coefficients were used to examine the variables estimated by wearable devices. Results: On the standardized day, the PAEE estimated using the metabolic chamber (PAEEcha) was 528.8 +/- 149.4 kcal/day. The PAEEs of all devices except the TANITA AM-160 (513.8 +/- 135.0 kcal/day; P>.05), SUZUKEN Lifecorder EX (519.3 +/- 89.3 kcal/day; P>.05), and Panasonic Actimarker (545.9 +/- 141.7 kcal/day; P>.05) were significantly different from the PAEEcha. None of the devices was correlated with PAEEcha according to both Pearson (r=-.13 to .37) and Spearman (rho=-.25 to .46) correlation tests. During the 15 free-living days, the PAEE estimated by DLW (PAEEdlw) was 728.0 +/- 162.7 kcal/day. PAEE values of all devices except the Omron Active style Pro (716.2 +/- 159.0 kcal/day; P>.05) and Omron CaloriScan (707.5 +/- 172.7 kcal/day; P>.05) were significantly underestimated. Only 2 devices, the Omron Active style Pro (r=.46; P=.045) and Panasonic Actimarker (r=.48; P=.04), had significant positive correlations with PAEEdlw according to Pearson tests. In addition, 3 devices, the TANITA AM-160 (rho=.50; P=.03), Omron CaloriScan (rho=.48; P=.04), and Omron Active style Pro (rho=.48; P=.04), could be ranked in PAEEdlw. Conclusions: Most wearable devices do not provide comparable PAEE estimates when using gold standard methods during 1 standardized day or 15 free-living days. Continuous development and evaluations of these wearable devices are needed for better estimations of PAEE.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] ENERGY-EXPENDITURE IN LEAN AND OBESE-DIABETIC PATIENTS USING THE DOUBLY LABELED WATER METHOD
    CHONG, PKK
    JUNG, RT
    RENNIE, MJ
    SCRIMGEOUR, CM
    DIABETIC MEDICINE, 1993, 10 (08) : 729 - 735
  • [32] Total Energy Expenditure, Body Composition, Physical Activity, and Step Count in Japanese Preschool Children: A Study Based on Doubly Labeled Water
    Yamada, Yosuke
    Sagayama, Hiroyuki
    Itoi, Aya
    Nishimura, Makoto
    Fujisawa, Kaori
    Higaki, Yasuki
    Kimura, Misaka
    Aoki, Yoshiko
    NUTRIENTS, 2020, 12 (05)
  • [33] Total energy expenditure of 10- to 12-year-old Japanese children measured using the doubly labeled water method
    Keisuke Komura
    Satoshi Nakae
    Kazufumi Hirakawa
    Naoyuki Ebine
    Kazuhiro Suzuki
    Haruo Ozawa
    Yosuke Yamada
    Misaka Kimura
    Kojiro Ishii
    Nutrition & Metabolism, 14
  • [34] Total energy expenditure of 10-to 12-year-old Japanese children measured using the doubly labeled water method
    Komura, Keisuke
    Nakae, Satoshi
    Hirakawa, Kazufumi
    Ebine, Naoyuki
    Suzuki, Kazuhiro
    Ozawa, Haruo
    Yamada, Yosuke
    Kimura, Misaka
    Ishii, Kojiro
    NUTRITION & METABOLISM, 2017, 14
  • [35] LONGITUDINAL CHANGES IN TOTAL ENERGY EXPENDITURE OF BOYS AND GIRLS AND REPEAT VALIDATION OF THE SEVEN-DAY PHYSICAL ACTIVITY RECALL AGAINST DOUBLY LABELED WATER
    Roemmich, J. N.
    Clark, P. A.
    Weltman, A.
    Rogol, A. D.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S36 - S36
  • [36] Validation of the doubly labeled water method in bald eagles (Haliaeetus leucocephalus) and a comparison of two equations for the calculation of energy expenditure
    Dykstra, CR
    Meyer, MW
    Karasov, WH
    PHYSIOLOGICAL ZOOLOGY, 1997, 70 (01): : 19 - 26
  • [37] Assessment of free living daily energy expenditure and physical activity in CHF: validation of a questionnaire with doubly labelled water
    Garet, MMartin
    Normand, S.
    Laville, M.
    Gabert, L.
    Sauvinet, V.
    Da Costa, A.
    Barthelemy, J. C.
    Roche, F.
    EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 287 - 287
  • [38] Comparison of energy expenditure estimates from 4 physical activity questionnaires with doubly labeled water estimates in postmenopausal women
    Mahabir, Somdat
    Baer, David J.
    Giffen, Carol
    Clevidence, Beverly A.
    Campbell, William S.
    Taylor, Philip R.
    Hartman, Terry J.
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2006, 84 (01): : 230 - 236
  • [39] Assessment of energy expenditure using doubly labeled water, physical activity by accelerometer and reported dietary intake in Japanese men with type 2 diabetes: A preliminary study
    Yoshimura, Eiichi
    Ohkawara, Kazunori
    Ishikawa-Takata, Kazuko
    Yamada, Satoru
    Tokui, Mikiya
    Funae, Osamu
    Takimoto, Hidemi
    Katsukawa, Fuminori
    JOURNAL OF DIABETES INVESTIGATION, 2019, 10 (02) : 318 - 321
  • [40] Assessing daily physical activity in elementary school students used by accelerometer: A validation study against doubly labeled water method
    Adachi, Minoru
    Sasayama, Kensaku
    Hikihara, Yuki
    Okishima, Kyota
    Mizuuchi, Hidetugu
    Sunami, Yoshiyuki
    Shiomi, Masako
    Nishimuta, Mamoru
    Kikunaga, Shigeji
    Tanaka, Hiroaki
    Saitoh, Shinichi
    Yoshitake, Yutaka
    JAPANESE JOURNAL OF PHYSICAL FITNESS AND SPORTS MEDICINE, 2007, 56 (03) : 347 - 355