The Accuracy of Smart Devices for Measuring Physical Activity in Daily Life: Validation Study

被引:44
|
作者
Degroote, Laurent [1 ,2 ]
De Bourdeaudhuij, Ilse [1 ]
Verloigne, Maite [1 ]
Poppe, Louise [1 ,2 ]
Crombez, Geert [2 ]
机构
[1] Univ Ghent, Phys Act & Hlth, Dept Movement & Sports Sci, Watersportlaan 2, B-9000 Ghent, Belgium
[2] Univ Ghent, Hlth Psychol, Dept Expt Clin & Hlth Psychol, Ghent, Belgium
来源
JMIR MHEALTH AND UHEALTH | 2018年 / 6卷 / 12期
关键词
physical activity; fitness trackes; accelerometry; ACTIVITY QUESTIONNAIRE; ACTIVITY MONITORS; SELF-EFFICACY; VALIDITY; HEALTH; FITNESS; ADULTS; RELIABILITY; CALIBRATION; PEDOMETER;
D O I
10.2196/10972
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Wearables for monitoring physical activity (PA) are increasingly popular. These devices are not only used by consumers to monitor their own levels of PA but also by researchers to track the behavior of large samples. Consequently, it is important to explore how accurately PA can be tracked via these devices. Objectives: The aim of this study was, therefore, to investigate convergent validity of 3 Android Wear smartwatches-Polar M600 (Polar Electro Oy, Kempele, Finland), Huawei Watch (Huawei Technologies Co, Ltd, Shenzhen, Guangdong, China), Asus Zenwatch3 (AsusTek Computer Inc, Taipei, Taiwan)-and Fitbit Charge with an ActiGraph accelerometer for measuring steps and moderate to vigorous physical activity (MVPA) on both a day level and 15-min level. Methods: A free-living protocol was used in which 36 adults engaged in usual daily activities over 2 days while wearing 2 different wearables on the nondominant wrist and an ActiGraph GT3X+ accelerometer on the hip. Validity was evaluated on both levels by comparing each wearable with the ActiGraph GT3X+ accelerometer using correlations and Bland-Altman plots in IBM SPSS 24.0. Results: On a day level, all devices showed strong correlations (Spearman r=.757-.892) and good agreement (interclass correlation coefficient, ICC=.695-.885) for measuring steps, whereas moderate correlations (Spearman r=.557-.577) and low agreement (ICC=.377-.660) for measuring MVPA. Bland-Altman revealed a systematic overestimation of the wearables for measuring steps but a variation between over-and undercounting of MVPA. On a 15-min level, all devices showed strong correlations (Spearman r=.752-.917) and good agreement (ICC=.792-.887) for measuring steps, whereas weak correlations (Spearman r=.116-.208) and low agreement (ICC=.461-.577) for measuring MVPA. Bland-Altman revealed a systematic overestimation of the wearables for steps but under- or overestimation for MVPA depending on the device. Conclusions: In sum, all 4 consumer-level devices can be considered accurate step counters in free-living conditions. This study, however, provides evidence of systematic bias for all devices in measurement of MVPA. The results on a 15-min level also indicate that these devices are not sufficiently accurate to provide correct real-time feedback.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Activity Monitors as Support for Older Persons' Physical Activity in Daily Life: Qualitative Study of the Users' Experiences
    Ehn, Maria
    Eriksson, Lennie Carlen
    Akerberg, Nina
    Johansson, Ann-Christin
    JMIR MHEALTH AND UHEALTH, 2018, 6 (02):
  • [32] Validation of the Digiwalker™ pedometer for measuring physical activity in young children
    McKee, DP
    Boreham, CAG
    Murphy, MH
    Nevill, AM
    PEDIATRIC EXERCISE SCIENCE, 2005, 17 (04) : 345 - 352
  • [33] Validation of the Gruve Triaxial Accelerometer System For Measuring Physical Activity
    Manohar, Chinmay U.
    Koepp, Gabe
    Mc Crady-Spitzer, Shelly
    Levine, James
    OBESITY, 2010, 18 : S133 - S133
  • [34] Validity of cardiac implantable electronic devices in assessing daily physical activity
    Pressler, Axel
    Danner, Michael
    Esefeld, Katrin
    Haller, Bernhard
    Scherr, Johannes
    Schoemig, Albert
    Halle, Martin
    Kolb, Christof
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : 1127 - 1130
  • [35] Validation of Physical Activity Using a Daily Diary in Comparison to Accelerometry in Adolescents
    Austin, Kate S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 898 - 898
  • [36] Daily physical activity assessment with accelerometers: new insights and validation studies
    Plasqui, G.
    Bonomi, A. G.
    Westerterp, K. R.
    OBESITY REVIEWS, 2013, 14 (06) : 451 - 462
  • [37] Assessment of physical activity in daily life in patients with musculoskeletal pain
    Verbunt, Jeanine A.
    Huijnen, Ivan P. J.
    Koke, Albere
    EUROPEAN JOURNAL OF PAIN, 2009, 13 (03) : 231 - 242
  • [38] Effects of bariatric surgery on physical activity in daily life in women
    Galvan, Carrie C. R.
    Morita, Andrea A.
    Nellessen, Aline G.
    Costa, Andreia C. T.
    Garcia, Naiara M.
    Tolla, Valeria A.
    Valezi, Antonio C.
    Barbosa, Decio S.
    Pitta, Fabio
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [39] Assessing physical activity in the daily life of cystic fibrosis patients
    Dias, Andre
    Gorzelniak, Lukas
    Joerres, Rudolf A.
    Fischer, Rainald
    Hartvigsen, Gunnar
    Horsch, Alexander
    PERVASIVE AND MOBILE COMPUTING, 2012, 8 (06) : 837 - 844
  • [40] Soldiers' physical activity of daily life: a systematic literature review
    Schilz, Christin
    Sammito, Stefan
    JOURNAL OF PUBLIC HEALTH-HEIDELBERG, 2023, 31 (05): : 773 - 780