Biomechanical Analysis of the Ross Procedure in an Ex Vivo Left Heart Simulator

被引:1
|
作者
Bryan, Amelia Y. [1 ]
Brandon Strong, E. [1 ]
Kidambi, Sumanth [1 ]
Gilligan-Steinberg, Shane [1 ]
Bennett-Kennett, Ross [2 ]
Lee, James Y. [1 ]
Imbrie-Moore, Annabel [1 ,3 ]
Moye, Stephen C. [1 ]
Hendrickx-Rodriguez, Sebastian [3 ]
Wang, Hanjay [1 ]
Dauskardt, Reinhold H. [2 ]
Joseph Woo, Y. [1 ,4 ]
Ma, Michael R. [1 ]
机构
[1] Stanford Univ, Dept Cardiothorac Surg, Palo Alto, CA 94304 USA
[2] Stanford Univ, Dept Mat Sci & Engn, Palo Alto, CA 94304 USA
[3] Stanford Univ, Dept Mech Engn, Palo Alto, CA 94304 USA
[4] Stanford Univ, Dept Bioengn, Palo Alto, CA 94304 USA
基金
美国国家卫生研究院;
关键词
autograft; Ross operation; pulmonary valve; aortic root; aortic valve; replacement; AORTIC-VALVE-REPLACEMENT; PULMONARY; CHILDREN; ROOT; AUTOGRAFT; OUTCOMES; MODEL; PHYSIOLOGY; SURGERY;
D O I
10.1177/21501351211070288
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Neo-aortic pulmonary autografts often experience root dilation and valve regurgitation over time. This study seeks to understand the biomechanical differences between aortic and neo-aortic pulmonary roots using a heart simulator. Methods: Porcine aortic, neo-aortic pulmonary, and pulmonary roots (n = 6) were mounted in a heart simulator (parameters: 100 mm Hg, 37 degrees C, 70 cycles per minute, 5.0 Unnin cardiac output). Echocardiography was used to study root distensibility (percentage change in luminal diameter between systole and diastole) and valve function. Leaflet motion was tracked with high-speed videography. After 30 min in the simulator, leaflet thickness (via cryosectioning), and multiaxial modulus (via lenticular hydrostatic deformation testing) were obtained. Results: There were no significant differences between aortic and neo-aortic pulmonary leaflet motion, including mean opening velocity (218 vs 248 mm/s, P = .27) or mean closing velocity (116 vs 157 mm/s, P = .12). Distensibility was similar between aortic (8.5%, 1.56 mm) and neo-aortic pulmonary (7.8%, 1.12 mm) roots (P = .59). Compared to virgin controls, native pulmonic roots exposed to systemic pressure for 30 min had reduced leaflet thickness (630 vs 385 mu m, P = .049) and a reduced Young's modulus (3,125 vs 1,089 kPa, P = .077). In contrast, the aortic roots exposed to pressure displayed no significant difference in aortic leaflet thickness (1,317 vs 1,256 pm, P = .27) or modulus (5,931 vs 3,631 kPa, P = .56). Conclusions: Neoaortic pulmonary roots demonstrated equivalence in valve function and distensibility but did experience changes in biomechanical properties and morphology. These changes may contribute to long-term complications associated with the Ross procedure.
引用
收藏
页码:166 / 174
页数:9
相关论文
共 50 条
  • [41] Ross procedure in congenital patients: Results and left ventricular function
    Rubay, JE
    Shango, P
    Clement, S
    Ovaert, C
    Matta, A
    Vliers, A
    Sluysmans, T
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (01) : 92 - 98
  • [42] Percutaneous closure of left ventricular pseudoaneurysms after Ross procedure
    Elshershari, Huda
    Gossett, Jeffrey G.
    Hijazi, Ziyad M.
    ANNALS OF THORACIC SURGERY, 2008, 85 (02): : 634 - 636
  • [43] Ross procedure for complex left ventricular outflow tract obstruction
    Wilson, WR
    Greer, GE
    Durzinsky, DS
    Curtis, JJ
    JOURNAL OF CARDIOVASCULAR SURGERY, 2000, 41 (03): : 387 - 392
  • [44] Regression of left ventricular hypertrophy in children following the Ross procedure
    Lehoux, Juan
    Swartz, Michael F.
    Atallah-Yunes, Nader
    Cholette, Jill M.
    Alfieris, George M.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 18 (05) : 607 - 610
  • [45] Computational Simulation of in vivo Pulmonary Autograft Early After the Ross Procedure: Wall Stress Analysis
    Xuan, Yue
    Moghaddam, Hesam S.
    El-Hamamsy, Ismail
    Mongeon, Francois-Pierre
    Leask, Richard L.
    Emmott, Alexander
    Tseng, Elaine E.
    Ge, Liang
    CARDIOLOGY, 2016, 134 (02) : 146 - 146
  • [46] Ex vivo accommodation simulator II - Concept and preliminary results
    Ehrmann, K
    Ho, A
    Parel, JM
    OPHTHALMIC TECHNOLOGIES XIV, 2004, 5314 : 48 - 58
  • [47] An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty
    Belkoff, SM
    Mathis, JM
    Deramond, H
    Jasper, LE
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (06) : 1212 - 1216
  • [48] Rotator cuff repair: A biomechanical ex vivo ovine study
    Bisbinas, Ilias
    Magnissalis, Evangelos
    Gigis, Ioannis
    Beslikas, Theodoros
    Hatzokos, Ippokratis
    Christoforidis, Ioannis
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H5) : 560 - 570
  • [49] Biomechanical Characterization of Keratoconus Corneas Ex Vivo With Brillouin Microscopy
    Scarcelli, Giuliano
    Besner, Sebastien
    Pineda, Roberto
    Yun, Seok Hyun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (07) : 4490 - 4495
  • [50] An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty
    Belkoff, SM
    Mathis, JM
    Jasper, LE
    Deramond, H
    SPINE, 2001, 26 (14) : 1542 - 1546