Biomechanical Analysis of the Ross Procedure in an Ex Vivo Left Heart Simulator

被引:1
|
作者
Bryan, Amelia Y. [1 ]
Brandon Strong, E. [1 ]
Kidambi, Sumanth [1 ]
Gilligan-Steinberg, Shane [1 ]
Bennett-Kennett, Ross [2 ]
Lee, James Y. [1 ]
Imbrie-Moore, Annabel [1 ,3 ]
Moye, Stephen C. [1 ]
Hendrickx-Rodriguez, Sebastian [3 ]
Wang, Hanjay [1 ]
Dauskardt, Reinhold H. [2 ]
Joseph Woo, Y. [1 ,4 ]
Ma, Michael R. [1 ]
机构
[1] Stanford Univ, Dept Cardiothorac Surg, Palo Alto, CA 94304 USA
[2] Stanford Univ, Dept Mat Sci & Engn, Palo Alto, CA 94304 USA
[3] Stanford Univ, Dept Mech Engn, Palo Alto, CA 94304 USA
[4] Stanford Univ, Dept Bioengn, Palo Alto, CA 94304 USA
基金
美国国家卫生研究院;
关键词
autograft; Ross operation; pulmonary valve; aortic root; aortic valve; replacement; AORTIC-VALVE-REPLACEMENT; PULMONARY; CHILDREN; ROOT; AUTOGRAFT; OUTCOMES; MODEL; PHYSIOLOGY; SURGERY;
D O I
10.1177/21501351211070288
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Neo-aortic pulmonary autografts often experience root dilation and valve regurgitation over time. This study seeks to understand the biomechanical differences between aortic and neo-aortic pulmonary roots using a heart simulator. Methods: Porcine aortic, neo-aortic pulmonary, and pulmonary roots (n = 6) were mounted in a heart simulator (parameters: 100 mm Hg, 37 degrees C, 70 cycles per minute, 5.0 Unnin cardiac output). Echocardiography was used to study root distensibility (percentage change in luminal diameter between systole and diastole) and valve function. Leaflet motion was tracked with high-speed videography. After 30 min in the simulator, leaflet thickness (via cryosectioning), and multiaxial modulus (via lenticular hydrostatic deformation testing) were obtained. Results: There were no significant differences between aortic and neo-aortic pulmonary leaflet motion, including mean opening velocity (218 vs 248 mm/s, P = .27) or mean closing velocity (116 vs 157 mm/s, P = .12). Distensibility was similar between aortic (8.5%, 1.56 mm) and neo-aortic pulmonary (7.8%, 1.12 mm) roots (P = .59). Compared to virgin controls, native pulmonic roots exposed to systemic pressure for 30 min had reduced leaflet thickness (630 vs 385 mu m, P = .049) and a reduced Young's modulus (3,125 vs 1,089 kPa, P = .077). In contrast, the aortic roots exposed to pressure displayed no significant difference in aortic leaflet thickness (1,317 vs 1,256 pm, P = .27) or modulus (5,931 vs 3,631 kPa, P = .56). Conclusions: Neoaortic pulmonary roots demonstrated equivalence in valve function and distensibility but did experience changes in biomechanical properties and morphology. These changes may contribute to long-term complications associated with the Ross procedure.
引用
收藏
页码:166 / 174
页数:9
相关论文
共 50 条
  • [31] A MUSCULAR CONTROLLED, EX-VIVO GLENOHUMERAL SIMULATOR
    Genter, Jeremy
    Rauter, Goerg
    Rohner, Markus
    Mueller, Andreas M.
    Mundermann, Annegret
    Baumgartner, Daniel
    SWISS MEDICAL WEEKLY, 2022, 152 : 28S - 29S
  • [32] Radiographical Texture Analysis Improves the Prediction of Vertebral Fracture An Ex Vivo Biomechanical Study
    Guenoun, Daphne
    Le Corroller, Thomas
    Acid, Souad
    Pithioux, Martine
    Pauly, Vanessa
    Ariey-Bonnet, Damien
    Chabrand, Patrick
    Champsaur, Pierre
    SPINE, 2013, 38 (21) : E1320 - E1326
  • [33] MOTION CAPTURE ANALYSIS OF EX VIVO KNEE KINEMATIC SIMULATOR: A COMPREHENSIVE EXPERIMENTAL PROTOCOL
    Bori, Edoardo
    Innocenti, Bernardo
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2023, 23 (06)
  • [34] Novel ex vivo left and right ventricular working heart model for xenotransplantation studies
    Abicht, Jan-Michael
    Jauch, Judith
    Thorman, Michael
    Buchholz, Stefan
    Postrach, Johannes
    Thein, Eckhart
    Brenner, Paolo
    Reichart, Bruno
    Christ, Frank
    Bauer, Andreas
    XENOTRANSPLANTATION, 2011, 18 (05) : 301 - 301
  • [35] The role of Ross procedure in the management of congenital heart defects
    Hartyanszky, Istvan
    Kollar, Andras
    Kadar, Krisztina
    Ablonczy, Laszlo
    Novak, Edit
    Toth, Attila
    ORVOSI HETILAP, 2013, 154 (06) : 219 - 224
  • [36] The landscape of congenital heart disease treated with the Ross procedure
    Bojko, Markian M.
    Wiggins, Luke
    Cleveland, John D.
    Bagrodia, Neelesh
    Elsayed, Ramsey S.
    Cleveland, David C.
    Starnes, Vaughn A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2025, 169 (03):
  • [37] Ross Procedure in Children: The Society of Thoracic Surgeons Congenital Heart Surgery Database Analysis
    Rowe, Georgina
    Gill, George
    Zubair, M. Mujeeb
    Roach, Amy
    Egorova, Natalia
    Emerson, Dominic
    Habib, Robert H.
    Bowdish, Michael E.
    Chikwe, Joanna
    Kim, Richard W.
    ANNALS OF THORACIC SURGERY, 2023, 115 (01): : 119 - 125
  • [38] Biomechanical engineering analysis of an acute papillary muscle rupture disease model using an innovative 3D-printed left heart simulator
    Marin-Cuartas, Mateo
    Zhu, Yuanjia
    Imbrie-Moore, Annabel M.
    Park, Matthew H.
    Wilkerson, Robert J.
    Leipzig, Matthew
    Pandya, Pearly K.
    Paulsen, Michael J.
    Borger, Michael A.
    Woo, Y. Joseph
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2022, 34 (05) : 822 - 830
  • [39] Biomechanical evaluation of a personalized external aortic root support applied in the Ross procedure
    Vastmans, Julie
    Fehervary, Heleen
    Verbrugghe, Peter
    Verbelen, Tom
    Vanderveken, Emma
    Sloten, Jos Vander
    Treasure, Tom
    Rega, Filip
    Famaey, Nele
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 78 : 164 - 174
  • [40] The Ross procedure: biomechanical properties of the pulmonary artery according to aortic valve phenotype
    Dionne, Pierre Olivier
    Wener, Evan
    Emmott, Alexander
    Cartier, Raymond
    Mongrain, Rosaire
    Leask, Richard
    El-Hamamsy, Ismail
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 23 (03) : 371 - 376