Biomechanical Analysis of the Ross Procedure in an Ex Vivo Left Heart Simulator

被引:1
|
作者
Bryan, Amelia Y. [1 ]
Brandon Strong, E. [1 ]
Kidambi, Sumanth [1 ]
Gilligan-Steinberg, Shane [1 ]
Bennett-Kennett, Ross [2 ]
Lee, James Y. [1 ]
Imbrie-Moore, Annabel [1 ,3 ]
Moye, Stephen C. [1 ]
Hendrickx-Rodriguez, Sebastian [3 ]
Wang, Hanjay [1 ]
Dauskardt, Reinhold H. [2 ]
Joseph Woo, Y. [1 ,4 ]
Ma, Michael R. [1 ]
机构
[1] Stanford Univ, Dept Cardiothorac Surg, Palo Alto, CA 94304 USA
[2] Stanford Univ, Dept Mat Sci & Engn, Palo Alto, CA 94304 USA
[3] Stanford Univ, Dept Mech Engn, Palo Alto, CA 94304 USA
[4] Stanford Univ, Dept Bioengn, Palo Alto, CA 94304 USA
基金
美国国家卫生研究院;
关键词
autograft; Ross operation; pulmonary valve; aortic root; aortic valve; replacement; AORTIC-VALVE-REPLACEMENT; PULMONARY; CHILDREN; ROOT; AUTOGRAFT; OUTCOMES; MODEL; PHYSIOLOGY; SURGERY;
D O I
10.1177/21501351211070288
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Neo-aortic pulmonary autografts often experience root dilation and valve regurgitation over time. This study seeks to understand the biomechanical differences between aortic and neo-aortic pulmonary roots using a heart simulator. Methods: Porcine aortic, neo-aortic pulmonary, and pulmonary roots (n = 6) were mounted in a heart simulator (parameters: 100 mm Hg, 37 degrees C, 70 cycles per minute, 5.0 Unnin cardiac output). Echocardiography was used to study root distensibility (percentage change in luminal diameter between systole and diastole) and valve function. Leaflet motion was tracked with high-speed videography. After 30 min in the simulator, leaflet thickness (via cryosectioning), and multiaxial modulus (via lenticular hydrostatic deformation testing) were obtained. Results: There were no significant differences between aortic and neo-aortic pulmonary leaflet motion, including mean opening velocity (218 vs 248 mm/s, P = .27) or mean closing velocity (116 vs 157 mm/s, P = .12). Distensibility was similar between aortic (8.5%, 1.56 mm) and neo-aortic pulmonary (7.8%, 1.12 mm) roots (P = .59). Compared to virgin controls, native pulmonic roots exposed to systemic pressure for 30 min had reduced leaflet thickness (630 vs 385 mu m, P = .049) and a reduced Young's modulus (3,125 vs 1,089 kPa, P = .077). In contrast, the aortic roots exposed to pressure displayed no significant difference in aortic leaflet thickness (1,317 vs 1,256 pm, P = .27) or modulus (5,931 vs 3,631 kPa, P = .56). Conclusions: Neoaortic pulmonary roots demonstrated equivalence in valve function and distensibility but did experience changes in biomechanical properties and morphology. These changes may contribute to long-term complications associated with the Ross procedure.
引用
收藏
页码:166 / 174
页数:9
相关论文
共 50 条
  • [21] Ex vivo Biomechanical Analysis of Elastic Artificial Chordae Implantation for Beating-heart Transapical Mitral Valve Repair
    Imbrie-Moore, Annabel M.
    Zhu, Yuanjia
    Park, Matthew
    Paulsen, Michael J.
    Wang, Hanjay
    Woo, Y. Joseph Y.
    CIRCULATION, 2020, 142
  • [22] Ex vivo Heart Function Analysis in Adult Zebrafish
    Dvornikov, Alexey, V
    Zhang Hong
    Xu Xiaolei
    CIRCULATION RESEARCH, 2017, 121
  • [23] Commentary: A novel cross-species model of Barlow's disease to biomechanically analyze repair techniques in an ex vivo left heart simulator
    Briffa, Norman
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 161 (05): : 1784 - 1785
  • [24] Ex vivo evaluation of the whole heart function allowing selective investigation of the right and left heart
    Steen, Stig
    Paskevicius, Audrius
    Liao, Qiuming
    Steen, Erik
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2024, 58 (01)
  • [25] Comparison of Wall Stresses After Ross Procedure Using Ex-Vivo Pulmonary Autograft vs in-vivo Autograft Imaging
    Xuan, Yue
    Wang, Zhongjie
    Kumar, Shalni
    El-Hamamsy, Ismail
    Pierre-Mongeon, Francois
    Leask, Richard
    Ge, Liang
    Tseng, Elaine
    CIRCULATION, 2018, 138
  • [26] Ex vivo biomechanical analysis of two methods of osteosynthesis in canine mandibular fractures
    Eigio Isaka, Luciano Jose
    Binder do Prado, Antonia Maria do Rocio
    Villanova Junior, Jose Ademar
    Pimpao, Claudia Turra
    Soares Junior, Paulo Cesar
    SEMINA-CIENCIAS AGRARIAS, 2017, 38 (04): : 1925 - 1932
  • [27] Biomechanical analysis of Graf's dynamic spine stabilisation system ex vivo
    Wild, A
    Jaeger, M
    Bushe, C
    Raab, P
    Krauspe, R
    BIOMEDIZINISCHE TECHNIK, 2001, 46 (10): : 290 - 294
  • [28] A prospective ex vivo biomechanical analysis of retrievable inferior vena cava filters
    Ho, Kwok M.
    Chamberlain, Jenny
    Nasim, Sana
    Rogers, Frederick B.
    Kop, Alan
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2022, 10 (05) : 1095 - +
  • [29] Experimental analysis and biaxial biomechanical behaviour of ex-vivo sheep trachea
    Pandelani, Thanyani
    Ngwangwa, Harry
    Nemavhola, Fulufhelo
    FRONTIERS IN MATERIALS, 2023, 10
  • [30] Ex vivo biomechanical analysis of two ilium osteosyn thesis methods in dogs
    Villamayor Garcia, Erika Fernanda
    Wallau Schossler, Joao Eduardo
    de Mendonca Mueller, Daniel Curvello
    Gomes, Cristiano
    Callegaro Serafini, Gabriele Maria
    CIENCIA RURAL, 2010, 40 (09): : 1980 - 1986