Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration

被引:13
|
作者
Obata, Kenta [1 ]
Tsuchida, Satoshi [1 ]
Yamamoto, Hirokazu [1 ]
Thome, Kurtis [2 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Inst Geol & Geoinformat, Tsukuba, Ibaraki 3058567, Japan
[2] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
关键词
ASTER; MODIS; VNIR; cross-calibration; RCC; radiance; uncertainty; SPACEBORNE THERMAL EMISSION; SOLAR SPECTRAL IRRADIANCE; VICARIOUS CALIBRATION; SOLSPEC SPECTROMETER; COLLECTION; 6; TERRA MODIS; SENSORS; PRODUCTS; INDEX; INTERCOMPARISONS;
D O I
10.3390/s17081793
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Radiometric cross-calibration between the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) and the Terra-Moderate Resolution Imaging Spectroradiometer (MODIS) has been partially used to derive the ASTER radiometric calibration coefficient (RCC) curve as a function of date on visible to near-infrared bands. However, cross-calibration is not sufficiently accurate, since the effects of the differences in the sensor's spectral and spatial responses are not fully mitigated. The present study attempts to evaluate radiometric consistency across two sensors using an improved cross-calibration algorithm to address the spectral and spatial effects and derive cross-calibration-based RCCs, which increases the ASTER calibration accuracy. Overall, radiances measured with ASTER bands 1 and 2 are on averages 3.9% and 3.6% greater than the ones measured on the same scene with their MODIS counterparts and ASTER band 3N (nadir) is 0.6% smaller than its MODIS counterpart in current radiance/reflectance products. The percentage root mean squared errors (%RMSEs) between the radiances of two sensors are 3.7, 4.2, and 2.3 for ASTER band 1, 2, and 3N, respectively, which are slightly greater or smaller than the required ASTER radiometric calibration accuracy (4%). The uncertainty of the cross-calibration is analyzed by elaborating the error budget table to evaluate the International System of Units (SI)-traceability of the results. The use of the derived RCCs will allow further reduction of errors in ASTER radiometric calibration and subsequently improve interoperability across sensors for synergistic applications.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    LI Xiaoying GU Xingfa MIN Xiangjun YU Tao FU Qiaoyan ZHANG Yong LI Xiaowen State Key Laboratory of Remote Sensing Science Jointly Sponsored by the Institute of Remote Sensing Applications of Chinese Academy of Sciences and Beijing Normal University Beijing China Graduate University of Chinese Academy of Sciences Beijing China The Center for National Spaceborne Demonstration Beijing China Institut National de la Recherche Agronomique Climat Sol Environnement Avignon France China Center for Resource Satellite Data and Application Beijing China
    [J]. Science in China(Series E:Technological Sciences), 2005, (Series E:Technological Sciences) - 60
  • [22] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    Xiaoying Li
    Xingfa Gu
    Xiangjun Min
    Tao Yu
    Qiaoyan Fu
    Yong Zhang
    Xiaowen Li
    [J]. Science in China Series E Engineering & Materials Science, 2005, 48 (Suppl 2): : 44 - 60
  • [23] Radiometric Cross-Calibration of GF-4/IRS Based on MODIS Measurements
    Zhou, Xiang
    Feng, Duo
    Xie, Yong
    Tao, Zui
    Lv, Tingting
    Wang, Jin
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2021, 14 : 6807 - 6814
  • [24] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    LI Xiaoying1
    2. Graduate University of Chinese Academy of Sciences
    3. The Center for National Spaceborne Demonstration
    4. Institut National de la Recherche Agronomique
    5. China Center for Resource Satellite Data and Application
    [J]. Science China Technological Sciences, 2005, (S2) : 44 - 60
  • [25] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    Li, XY
    Gu, XF
    Min, XJ
    Yu, TA
    Fu, QY
    Zhang, Y
    Li, XW
    [J]. SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2005, 48 : 44 - 60
  • [26] Radiometric calibration of the visible and near-infrared bands of SEVIRI using rayleigh scattering and Sun-glint over oceans
    Nicolas, Jean-Marc
    Deschamps, Pierre-Yves
    Hagolle, Olivier
    [J]. PROCEEDINGS OF THE 3RD MSG RAO WORKSHOP, 2006, 619 : 19 - +
  • [27] Toward consistent radiometric calibration of the NOAA AVHRR visible and near-infrared data record
    Bhatt, Rajendra
    Doelling, David R.
    Scarino, Benjamin R.
    Gopalan, Arun
    Haney, Conor O.
    [J]. EARTH OBSERVING SYSTEMS XX, 2015, 9607
  • [28] Radiometric Cross-Calibration of Tiangong-2 MWI Visible/NIR Channels over Aquatic Environments using MODIS
    Zhou, Qu
    Tian, Liqiao
    Li, Jian
    Song, Qingjun
    Li, Wenkai
    [J]. REMOTE SENSING, 2018, 10 (11):
  • [29] Calibration of a visible and near-infrared portable transfer radiometer
    Biggar, SF
    [J]. METROLOGIA, 1998, 35 (04) : 701 - 706