An experiment was carried out on a domestic condensing heat recovery air-conditioner. The working principle was introduced in this article. And thermal performance and theoretical analysis of the dynamic behavior of the system were conducted followed by experimental investigation. The results illustrated that the operating parameters of various modes were satisfactory. In the summer and winter seasons, the space cooling performance (COPsc) and space heating performance (COPsh) values were 2.85 and 3.37, respectively. In the condensing heat recovery for water heating mode, the average COPwh was found to be 2.58, and the COPsc was observed to be 2.84 with an overall coefficient of performance (COPcw) of up to 5.42; the mean heat recovery rate was about 95%. In water heating only mode, the heat capacity was declining with an average COPwh value of 3.94.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] RESEARCH ON HEAT PIPE AIR-CONDITIONER WITH SOIL HEAT EXCHANGER FOR BASE STATION
    Zhang, Ying
    Jin, Luqi
    Fan, Xiaowei
    Zhang, Zhuming
    THERMAL SCIENCE, 2024, 28 (3A): : 2075 - 2081
  • [42] Mechanism of enhancing heat transfer performance of an automobile air-conditioner evaporator plating with hydrophilic film
    Cao, X. L.
    Zhang, M. X.
    Ouyang, Q.
    Feng, M. K.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 361 - 365
  • [43] Performance characterisation of liquid desiccant columns for a hybrid air-conditioner
    Mohan, B. Shaji
    Maiya, M. Prakash
    Tiwari, Shaligram
    APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) : 1342 - 1355
  • [44] Performance improvement by mass-heat recovery of an innovative adsorption air-conditioner driven by 50-80 °C hot water
    Lu, Z. S.
    Wang, R. Z.
    APPLIED THERMAL ENGINEERING, 2013, 55 (1-2) : 113 - 120
  • [45] Multi-stage liquid-desiccant air-conditioner: Experimental performance and model development
    McNevin, Christopher
    Harrison, Stephen J.
    BUILDING AND ENVIRONMENT, 2017, 114 : 45 - 55
  • [46] Performance evaluation and design considerations for a split air-conditioner with built-in thermal energy storage
    Ahmad, Jehanzeb
    Ul Islam, M. Najam
    Sabir, Jawwad
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2019, 40 (05): : 560 - 575
  • [47] A universal method for performance evaluation of solar photovoltaic air-conditioner
    Zhao, B. Y.
    Li, Y.
    Wang, R. Z.
    Zhao, Z. G.
    Taylor, R. A.
    SOLAR ENERGY, 2018, 172 : 58 - 68
  • [48] Quantifying householder tolerance of thermal discomfort before turning on air-conditioner
    Ryu, Jihye
    Kim, Jungsoo
    Hong, Wonhwa
    de Dear, Richard
    ENERGY AND BUILDINGS, 2020, 211
  • [49] Enhanced condensation heat transfer in air-conditioner heat exchanger using superhydrophobic foils
    Wang, Shanlin
    Yu, Xinquan
    Liang, Caihua
    Zhang, Youfa
    APPLIED THERMAL ENGINEERING, 2018, 137 : 758 - 766
  • [50] Experimental study of the application of intermittently operated SEHRAC (storage-enhanced heat recovery room air-conditioner) in residential buildings in Hong Kong
    Jia, Jie
    Lee, W. L.
    ENERGY, 2015, 83 : 628 - 637