Experimental investigations on the thermal performance of a domestic condensing heat recovery air-conditioner

被引:3
|
作者
Qiu, Fuqiang [1 ,2 ]
Li, Baoguo [1 ]
Xu, Taoping [2 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Tongling Polytech, Dept Elect Engn, Tongling, Peoples R China
关键词
Air-conditioner; condensing heat recovery; heat pump water heater; energy conservation; coefficient of performance; capillary tube;
D O I
10.1177/1687814018822349
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experiment was carried out on a domestic condensing heat recovery air-conditioner. The working principle was introduced in this article. And thermal performance and theoretical analysis of the dynamic behavior of the system were conducted followed by experimental investigation. The results illustrated that the operating parameters of various modes were satisfactory. In the summer and winter seasons, the space cooling performance (COPsc) and space heating performance (COPsh) values were 2.85 and 3.37, respectively. In the condensing heat recovery for water heating mode, the average COPwh was found to be 2.58, and the COPsc was observed to be 2.84 with an overall coefficient of performance (COPcw) of up to 5.42; the mean heat recovery rate was about 95%. In water heating only mode, the heat capacity was declining with an average COPwh value of 3.94.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Domestic air-conditioner and integrated water heater for subtropical climate
    Ji, J
    Chow, TT
    Pei, G
    Dong, J
    He, W
    APPLIED THERMAL ENGINEERING, 2003, 23 (05) : 581 - 592
  • [22] Performance of a solar integrated heat pump air-conditioner, water heater and dryer
    Hawlader, M. N. A.
    Shaochun, Ye
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2008, 29 (04) : 189 - 196
  • [23] Effect of condensing unit layout at building re-entrant on split-type air-conditioner performance
    Chow, TT
    Lin, Z
    Liu, JP
    ENERGY AND BUILDINGS, 2002, 34 (03) : 237 - 244
  • [24] Applying storage-enhanced heat recovery room air-conditioner (SEHRAC) for domestic water heating in residential buildings in Hong Kong
    Jia, Jie
    Lee, W. L.
    ENERGY AND BUILDINGS, 2014, 78 : 132 - 142
  • [25] Indoor thermal environment in a rural dwelling heated by air-source heat pump air-conditioner
    Ma, Shengyuan
    Liu, Wei
    Dong, Jiankai
    Liu, Jing
    Wang, Zhaojun
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 51
  • [26] Design and performance analysis of a metal hydride air-conditioner
    Gopal, MR
    Murthy, SS
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1997, 21 (01) : 55 - 67
  • [27] Feasibility of a compact heat recovery ventilator module with an integrated air-cooled solar absorption air-conditioner
    Kim, D. S.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2011, 50 (08) : 1604 - 1614
  • [28] TRANSMISSION VOLTAGE RECOVERY DELAYED BY STALLED AIR-CONDITIONER COMPRESSORS
    WILLIAMS, BR
    SCHMUS, WR
    DAWSON, DC
    TAYLOR, CW
    FAYBISOVICH, VA
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1992, 7 (03) : 1173 - 1181
  • [29] Experimental study on the effect of air outflow parameters of wall mounted air-conditioner on the indoor thermal environment
    Lai, Y. H.
    Zhang, J. G.
    Guo, L.
    Lin, Charlie
    Lu, M. X.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 492 - 498
  • [30] Effect of Dents in Condenser Fins on Air-Conditioner Performance
    Sitzmann, Matthew J.
    Lu, Frank K.
    Smith, Steve R.
    ASHRAE TRANSACTIONS 2010, VOL 116, PT 1, 2010, 116 : 336 - +