Experimental investigations on the thermal performance of a domestic condensing heat recovery air-conditioner

被引:3
|
作者
Qiu, Fuqiang [1 ,2 ]
Li, Baoguo [1 ]
Xu, Taoping [2 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Tongling Polytech, Dept Elect Engn, Tongling, Peoples R China
关键词
Air-conditioner; condensing heat recovery; heat pump water heater; energy conservation; coefficient of performance; capillary tube;
D O I
10.1177/1687814018822349
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experiment was carried out on a domestic condensing heat recovery air-conditioner. The working principle was introduced in this article. And thermal performance and theoretical analysis of the dynamic behavior of the system were conducted followed by experimental investigation. The results illustrated that the operating parameters of various modes were satisfactory. In the summer and winter seasons, the space cooling performance (COPsc) and space heating performance (COPsh) values were 2.85 and 3.37, respectively. In the condensing heat recovery for water heating mode, the average COPwh was found to be 2.58, and the COPsc was observed to be 2.84 with an overall coefficient of performance (COPcw) of up to 5.42; the mean heat recovery rate was about 95%. In water heating only mode, the heat capacity was declining with an average COPwh value of 3.94.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] PERFORMANCE DEGRADATION OF AN AIR-CONDITIONER CAUSED BY CYCLIC OPERATIONS
    BAHEL, V
    BAKHSH, H
    ZUBAIR, S
    ENERGY, 1988, 13 (02) : 191 - 195
  • [32] PERFORMANCE EVALUATION OF SOLAR-POWERED AIR-CONDITIONER
    TANAKA, K
    DING, L
    MAKINO, Y
    SAKOGUCHI, E
    TAKEOKA, A
    YAMADA, E
    ELECTRICAL ENGINEERING IN JAPAN, 1994, 114 (08) : 30 - 40
  • [33] Numerical Simulation for Thermal Distribution of Air-conditioner Outdoor Units
    Tong, Li-Ge
    Zhang, Zhen
    Wang, Li
    Yin, Shao-Wu
    Yu, Jiangfeng
    Liu, Chun
    JOURNAL OF THERMAL SCIENCE, 2012, 21 (03) : 269 - 275
  • [34] Efficiency enhancement of an air-conditioner utilizing nanofluids: An experimental study
    Ahmed, Faizan
    Khan, Waqar Ahmed
    ENERGY REPORTS, 2021, 7 (07) : 575 - 583
  • [35] Experimental investigations on adsorption air-conditioner used in internal-combustion locomotive driver-cabin
    Jiangzhou, S
    Wang, RZ
    Lu, YZ
    Xu, YX
    Wu, JY
    APPLIED THERMAL ENGINEERING, 2002, 22 (10) : 1153 - 1162
  • [36] Numerical experiment of thermal comfort in a bedroom equipped with air-conditioner
    Sin, VK
    Sun, HI
    Tam, LM
    Wong, KI
    COMPUTATIONAL METHODS IN ENGINEERING AND SCIENCE, PROCEEDINGS, 2003, : 787 - +
  • [38] Numerical simulation for thermal distribution of air-conditioner outdoor units
    Li-Ge Tong
    Zhen Zhang
    Li Wang
    Shao-Wu Yin
    Jiangfeng Yu
    Chun Liu
    Journal of Thermal Science, 2012, 21 : 269 - 275
  • [39] Working performance of R-32 two-stage compression system in domestic air-conditioner
    Xu Shuxue
    Ma Guoyuan
    ENERGY AND BUILDINGS, 2015, 93 : 324 - 331
  • [40] Experimental research on thermal behaviour of the office with a floor-mounted split type air-conditioner
    He, Tianqi
    Chongqing Jianzhu Daxue Xuebao/Journal of Chongqing Jianzhu University, 1996, 18 (03): : 31 - 41