Neutral carrier based needle-type sensor for the determination of calcium ion

被引:1
|
作者
Li, XL [1 ]
Hong, DQ [1 ]
Li, YY [1 ]
Lin, ZH [1 ]
Ren, S [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Chem, Wuhan 340030, Peoples R China
关键词
calcium ion; needle-type; neutral carrier; in vivo monitoring;
D O I
10.1117/12.440166
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Calcium ion is a very important messenger not only between cell and cell, but also in meridian main and collateral channels. A new neutral carrier PVC membrane based needle-type potential sensor was prepared, which shows a good selectivity for Ca2+. Responses characteristics, pH, response time of sensor, other metal ions such as Mg2+, Na+, and K+ in measuring calcium ion were investigated. The resulting sensor has a linear range from 1.0 x 10(-6) to 9.1 x 10(-3) mol/L. The sensor will be used in the detection of Ca2+ in vivo in muscular tissues of the mice.
引用
收藏
页码:115 / 117
页数:3
相关论文
共 50 条
  • [31] STUDY OF CALCIUM ION-SELECTIVE ELECTRODE BASED ON A NEW NEUTRAL CARRIER
    Wei XU Bin GUO You Rong NIE Zai Fu HUANG Department of Environmental Science
    ChineseChemicalLetters, 1993, (02) : 179 - 180
  • [32] Production of needle-type liquid-metal ion sources and their application in a scanning ion microscope
    Knapp, H.
    Ruebesame, D.
    Niedrig, H.
    Nuclear Instruments & Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1991, 59-60 (pt 1):
  • [33] Determination of Volatile Organic Compounds in Aqueous Samples by a Needle-type Extraction Device
    Ueta, Ikuo
    Saito, Yoshihiro
    BUNSEKI KAGAKU, 2016, 65 (01) : 25 - 32
  • [34] Determination of Volatile Polycyclic Aromatic Hydrocarbons in Soil Using Needle-Type Extraction
    Ueta, Ikuo
    Kamei, Syuhei
    Nakagami, Koki
    Saito, Yoshihiro
    CHROMATOGRAPHY, 2023, 44 (03) : 139 - 143
  • [35] NEW NEEDLE-TYPE COLLOID OSMOMETER FOR CONTINUOUS DETERMINATION OF BLOOD ONCOTIC PRESSURE
    KAKIUCHI, Y
    ARAI, T
    HORIMOTO, M
    KIKUCHI, Y
    KOYAMA, T
    AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 236 (04): : F419 - F422
  • [36] NEEDLE-TYPE GLUCOSE SENSORS BASED ON OXYGEN ELECTRODES WITH A NEW CONCEPT
    IKEDA, S
    KIMURA, M
    ITO, K
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (8B) : C501 - C501
  • [37] AMPEROMETRIC NEEDLE-TYPE GLUCOSE SENSOR BASED ON A MODIFIED PLATINUM-ELECTRODE WITH DIMINISHED RESPONSE TO INTERFERING MATERIALS
    CHEN, CY
    GOTOH, M
    MAKINO, H
    SU, YC
    TAMIYA, E
    KARUBE, I
    ANALYTICA CHIMICA ACTA, 1992, 265 (01) : 5 - 14
  • [38] Needle-type GMR sensor to estimate the magnetic properties of diluted ferrofluid for biomedicine application
    Shirzadfar, H.
    Nadi, M.
    Kourtiche, D.
    Yamada, S.
    Hauet, T.
    IRBM, 2015, 36 (03) : 178 - 184
  • [39] Magnetic Fluid Weight Density Estimation in Large Cavities by a Needle-type GMR Sensor
    Gooneratne, C. P.
    Iwahara, M.
    Kakikawa, M.
    Yamada, S.
    Kurnicki, A.
    Mukhopadhyay, S. C.
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY, 2008, : 642 - +
  • [40] MEMS needle-type sensor array for in situ measurements of dissolved oxygen and redox potential
    Lee, Jin-Hwan
    Seo, Youngwoo
    Lim, Tae-Sun
    Bishop, Paul L.
    Papautsky, Ian
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (22) : 7857 - 7863