Neutral carrier based needle-type sensor for the determination of calcium ion

被引:1
|
作者
Li, XL [1 ]
Hong, DQ [1 ]
Li, YY [1 ]
Lin, ZH [1 ]
Ren, S [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Chem, Wuhan 340030, Peoples R China
关键词
calcium ion; needle-type; neutral carrier; in vivo monitoring;
D O I
10.1117/12.440166
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Calcium ion is a very important messenger not only between cell and cell, but also in meridian main and collateral channels. A new neutral carrier PVC membrane based needle-type potential sensor was prepared, which shows a good selectivity for Ca2+. Responses characteristics, pH, response time of sensor, other metal ions such as Mg2+, Na+, and K+ in measuring calcium ion were investigated. The resulting sensor has a linear range from 1.0 x 10(-6) to 9.1 x 10(-3) mol/L. The sensor will be used in the detection of Ca2+ in vivo in muscular tissues of the mice.
引用
收藏
页码:115 / 117
页数:3
相关论文
共 50 条
  • [21] Development of a needle-type glucose sensor based on a titanium dioxide oxygen electrode for the artificial pancreas
    Ikeda, Shoichiro
    Hara, Masanori
    Hishida, Yuko
    Kimura, Masami
    Ito, Kaname
    Sensors and Actuators, B: Chemical, 1993, B13 (1 -3 pt 1) : 315 - 318
  • [22] A novel needle-type SV-GMR sensor for biomedical applications
    Mukhopadhyay, Subhas Chandra
    Chomsuwan, Komkrit
    Gooneratne, Chnithaka P.
    Yamada, Sotoshi
    IEEE SENSORS JOURNAL, 2007, 7 (3-4) : 401 - 408
  • [23] IMPROVED CALCIUM ION-SELECTIVE ELECTRODE BASED ON A NEUTRAL CARRIER
    AMMANN, D
    GUGGI, M
    PRETSCH, E
    SIMON, W
    ANALYTICAL LETTERS, 1975, 8 (10) : 709 - 720
  • [24] Fabrication of an Implantable Fine Needle-Type Glucose Sensor Using γ-Polyglutamic Acid
    Takaoka, Hiroki
    Yasuzawa, Mikito
    ANALYTICAL SCIENCES, 2010, 26 (05) : 551 - 555
  • [25] Fabrication of an Implantable Fine Needle-Type Glucose Sensor Using γ-Polyglutamic Acid
    Hiroki Takaoka
    Mikito Yasuzawa
    Analytical Sciences, 2010, 26 : 551 - 555
  • [26] Effect of recess dimensions on performance of the needle-type dissolved oxygen microelectrode sensor
    Lim, Tae-Sun
    Lee, Jin-Hwan
    Papautsky, Ian
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (01): : 50 - 57
  • [27] Calcium(II)-selective potentiometric sensor based on at-furildioxime as neutral carrier
    Singh, Ashok Kumar
    Mehtab, Sameena
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01): : 429 - 436
  • [28] Characterization and food application of an amperometric needle-type L-lactate sensor
    Kim, N
    Haginoya, R
    Karube, I
    JOURNAL OF FOOD SCIENCE, 1996, 61 (02) : 286 - 290
  • [29] Photocontrol of ion-sensor performances in neutral-carrier-type ion sensors based on liquid-crystalline membranes
    Oosaki, S
    Hayasaki, H
    Sakurai, Y
    Yajima, S
    Kimura, K
    CHEMICAL COMMUNICATIONS, 2005, (41) : 5226 - 5227
  • [30] DEVELOPMENT OF A NOUVELLE NEEDLE-TYPE GLUCOSE SENSOR BASED ON TITANIUM-OXIDE OXYGEN-ELECTRODE
    IKEDA, S
    KIMURA, M
    NODA, H
    ITO, K
    OHKURA, K
    NAKAO, A
    TAKAGI, H
    KONDO, T
    DENKI KAGAKU, 1988, 56 (12): : 1055 - 1062