Characteristics of a mixed-gas cluster ion beam for time-of-flight secondary ion mass spectrometry

被引:7
|
作者
Lee, Sang Ju [1 ]
Hong, Aram [1 ]
Cho, Jinwan [1 ]
Choi, Chang Min [1 ]
Baek, Ji Young [1 ]
Eo, Jae Yeong [2 ]
Cha, Byeong Jun [1 ]
Byeon, Woo Jun [1 ]
We, Jin Young [1 ]
Hyun, Sangwon [2 ]
Jeon, Minwoo [2 ]
Jeon, Choelho [3 ]
Ku, Dong Jin [4 ]
Choi, Myoung Choul [1 ]
机构
[1] Korea Basic Sci Inst, Ctr Sci Instrumentat, Cheongju, South Korea
[2] Korea Basic Sci Inst, Ctr Res Equipment, Daejeon, South Korea
[3] Korea Basic Sci Inst, Res Ctr Mat Anal, Daejeon, South Korea
[4] Y&DK Co Ltd, Ultraprecis Tech Res Inst, Daejeon, South Korea
关键词
Mixed-gas duster ion beam; Time-of-flight secondary ion mass spectrometry; CO2; clusters; Mass spectra; TOF-SIMS;
D O I
10.1016/j.apsusc.2021.151467
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The gas cluster ion beam (GCIB) is a valuable tool for surface analysis, providing new 3D mass analysis equipment possibilities. The main feature of the GCIB is that many particles are involved during the collision of the cluster ion beam with a sample surface. Studying the characteristics of the GCIB is essential for improving the performance of the analysis equipment. We evaluated the efficiency of the GCIB using a mixed-gas of Ar and CO2 as a primary ion beam for time-of-flight secondary ion mass spectrometry. We measured the characteristic factors and composition of the cluster ion beam depending on the mole fraction ratio of CO2/Ar. We measured that the CO2 composition of the output cluster ion beam rapidly increases to over 95% when the mole fraction ratio of CO2 increases by more than 10% in the injected mixed gas. Nevertheless, the optimal ratio of the CO2/Ar mole fraction (%) to increase the secondary ion efficiency was 96% CO2, which more than doubled the secondary ion efficiency over that of pure Ar clusters. The beam spot size began rapidly decreasing from 95% CO2, and it was reduced by up to 0.67 times at 100% CO2. According to the mixed-gas ratio, the sputtering yield of the Si wafer was 8 times lower than that of pure Ar clusters.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Analysis of surface particles by time-of-flight secondary ion mass spectrometry
    Chu, PK
    Odom, RW
    Reich, DF
    MATERIALS CHEMISTRY AND PHYSICS, 1996, 43 (02) : 87 - 94
  • [32] Pore confined time-of-flight secondary ion electrochemical mass spectrometry
    Wang, Jun-Gang
    Yu, Ru-Jia
    Hua, Xin
    Long, Yi-Tao
    CHEMICAL SOCIETY REVIEWS, 2023, 52 (08) : 2596 - 2616
  • [33] Investigation of molecular surfaces with time-of-flight secondary ion mass spectrometry
    Aoyagi, Satoka
    Namekawa, Koki
    Yamamoto, Kenichiro
    Sakai, Kiyotaka
    Kato, Nobuhiko
    Kudo, Masahiro
    SURFACE AND INTERFACE ANALYSIS, 2010, 42 (10-11) : 1593 - 1597
  • [34] TIME-OF-FLIGHT SECONDARY ION MASS-SPECTROMETRY OF PERFLUORINATED POLYETHERS
    BLETSOS, IV
    HERCULES, DM
    FOWLER, D
    VANLEYEN, D
    BENNINGHOVEN, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 200 : 7 - FLUO
  • [35] Protein Denaturation Detected by Time-of-Flight Secondary Ion Mass Spectrometry
    Killian, Manuela S.
    Krebs, Heike M.
    Schmuki, Patrik
    LANGMUIR, 2011, 27 (12) : 7510 - 7515
  • [36] TIME-OF-FLIGHT SECONDARY ION MASS-SPECTROMETRY OF POLYMER MATERIALS
    VANLEYEN, D
    HAGENHOFF, B
    NIEHUIS, E
    BENNINGHOVEN, A
    BLETSS, IV
    HERCULES, DM
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1989, 7 (03): : 1790 - 1794
  • [37] Characterization of cresol epoxy by time-of-flight secondary ion mass spectrometry
    Pan, YY
    Li, YS
    Cao, YM
    Chen, WX
    Zong, XF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (02) : 158 - 161
  • [38] Analysis of wood tissues by time-of-flight secondary ion mass spectrometry
    Tokareva, Elena N.
    Pranovich, Andrey V.
    FardiM, Pedro
    Danie, Geoffrey
    Holmbom, Bjarne
    HOLZFORSCHUNG, 2007, 61 (06) : 647 - 655
  • [39] Isotopic ratio measurements by time-of-flight secondary ion mass spectrometry
    Fahey, AJ
    Messenger, S
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) : 227 - 242
  • [40] Using Time-of-Flight Secondary Ion Mass Spectrometry to Study Biomarkers
    Thiel, Volker
    Sjovall, Peter
    ANNUAL REVIEW OF EARTH AND PLANETARY SCIENCES, VOL 39, 2011, 39 : 125 - 156