Characteristics of a mixed-gas cluster ion beam for time-of-flight secondary ion mass spectrometry

被引:7
|
作者
Lee, Sang Ju [1 ]
Hong, Aram [1 ]
Cho, Jinwan [1 ]
Choi, Chang Min [1 ]
Baek, Ji Young [1 ]
Eo, Jae Yeong [2 ]
Cha, Byeong Jun [1 ]
Byeon, Woo Jun [1 ]
We, Jin Young [1 ]
Hyun, Sangwon [2 ]
Jeon, Minwoo [2 ]
Jeon, Choelho [3 ]
Ku, Dong Jin [4 ]
Choi, Myoung Choul [1 ]
机构
[1] Korea Basic Sci Inst, Ctr Sci Instrumentat, Cheongju, South Korea
[2] Korea Basic Sci Inst, Ctr Res Equipment, Daejeon, South Korea
[3] Korea Basic Sci Inst, Res Ctr Mat Anal, Daejeon, South Korea
[4] Y&DK Co Ltd, Ultraprecis Tech Res Inst, Daejeon, South Korea
关键词
Mixed-gas duster ion beam; Time-of-flight secondary ion mass spectrometry; CO2; clusters; Mass spectra; TOF-SIMS;
D O I
10.1016/j.apsusc.2021.151467
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The gas cluster ion beam (GCIB) is a valuable tool for surface analysis, providing new 3D mass analysis equipment possibilities. The main feature of the GCIB is that many particles are involved during the collision of the cluster ion beam with a sample surface. Studying the characteristics of the GCIB is essential for improving the performance of the analysis equipment. We evaluated the efficiency of the GCIB using a mixed-gas of Ar and CO2 as a primary ion beam for time-of-flight secondary ion mass spectrometry. We measured the characteristic factors and composition of the cluster ion beam depending on the mole fraction ratio of CO2/Ar. We measured that the CO2 composition of the output cluster ion beam rapidly increases to over 95% when the mole fraction ratio of CO2 increases by more than 10% in the injected mixed gas. Nevertheless, the optimal ratio of the CO2/Ar mole fraction (%) to increase the secondary ion efficiency was 96% CO2, which more than doubled the secondary ion efficiency over that of pure Ar clusters. The beam spot size began rapidly decreasing from 95% CO2, and it was reduced by up to 0.67 times at 100% CO2. According to the mixed-gas ratio, the sputtering yield of the Si wafer was 8 times lower than that of pure Ar clusters.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] High energy gas cluster ions for organic and biological analysis by time-of-flight secondary ion mass spectrometry
    Angerer, Tina B.
    Blenkinsopp, Paul
    Fletcher, John S.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 377 : 591 - 598
  • [22] Application of Time-of-flight Secondary Ion Mass Spectrometry in Lithium-ion Batteries
    Li, Pengwei
    Xia, Xiaoning
    CURRENT ANALYTICAL CHEMISTRY, 2025, 21 (01) : 1 - 4
  • [23] Aberration-corrected focused ion beam for time-of-flight secondary neutral mass spectrometry
    Nagata, Kosuke
    Bajo, Ken-ichi
    Itose, Satoru
    Matsuya, Miyuki
    Ishihara, Morio
    Uchino, Kiichiro
    Yurimoto, Hisayoshi
    APPLIED PHYSICS EXPRESS, 2019, 12 (08)
  • [24] Time-of-flight secondary ion mass spectrometry (ToF-SIMS)
    Bertrand, P
    Weng, LT
    MIKROCHIMICA ACTA, 1996, : 167 - 182
  • [25] TIME-OF-FLIGHT SECONDARY-ION MASS-SPECTROMETRY OF POLYBUTADIENES
    HITTLE, LR
    HERCULES, DM
    SURFACE AND INTERFACE ANALYSIS, 1994, 21 (04) : 217 - 225
  • [26] Identification of human calculi with time-of-flight secondary ion mass spectrometry
    Ghumman, C. Amjad A.
    Carreira, Olga M. T.
    Moutinho, Augusto M. C.
    Tolstogouzov, Alexander
    Vassilenko, Valentina
    Teodoro, Orlando M. N. D.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (02) : 185 - 190
  • [27] Postacquisition Mass Resolution Improvement in Time-of-Flight Secondary Ion Mass Spectrometry
    Pachuta, Steven J.
    Vlasak, Paul R.
    ANALYTICAL CHEMISTRY, 2012, 84 (03) : 1744 - 1753
  • [28] TIME-OF-FLIGHT SECONDARY ION MASS-SPECTROMETRY OF PERFLUORINATED POLYETHERS
    BLETSOS, IV
    HERCULES, DM
    FOWLER, D
    VANLEYEN, D
    BENNINGHOVEN, A
    ANALYTICAL CHEMISTRY, 1990, 62 (13) : 1275 - 1284
  • [29] MICROSCOPE IMAGING BY TIME-OF-FLIGHT SECONDARY ION MASS-SPECTROMETRY
    SCHUELER, BW
    MICROSCOPY MICROANALYSIS MICROSTRUCTURES, 1992, 3 (2-3): : 119 - 139
  • [30] TIME-OF-FLIGHT MASS-SPECTROMETRY WITH AN ELECTROSPRAY ION-BEAM
    BOYLE, JG
    WHITEHOUSE, CM
    ANALYTICAL CHEMISTRY, 1992, 64 (18) : 2084 - 2089