In vitro evaluation of flow divertors in an elastase-induced saccular aneurysm model in rabbit

被引:63
|
作者
Seong, Jaehoon [1 ]
Wakhloo, Ajay K. [2 ]
Lieber, Baruch B. [1 ,3 ]
机构
[1] Univ Miami, Dept Biomed Engn, Coral Gables, FL 33146 USA
[2] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
[3] Univ Miami, Dept Radiol, Coral Gables, FL 33146 USA
关键词
elastase-induced saccular aneurysm; PIV; flow divertor; silicone replica; intra-aneurysmal flow;
D O I
10.1115/1.2800787
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Endovascular coiling is an acceptable treatment of intracranial aneurysms, yet long term follow-ups suggest that endovascular coiling fails to achieve complete aneurysm occlusions particularly in wide-neck and giant aneurysms. Placing of a stentlike device across the aneurysm neck may be sufficient to occlude the aneurysm by promoting intra-aneurysmal thrombosis; however, conclusive evidence of its efficacy is still lacking. In this study, we investigate in vitro the efficacy of custom designed flow divertors that will be subsequently implanted in a large cohort of animals. The aim of this study is to provide a detailed database against which in vivo results can be analyzed. Six custom designed flow divertors were fabricated and tested in vitro. The design matrix included three different porosities (75%, 70%, and 65%). For each porosity, there were two divertors with one having a nominal pore density double than that of the other. To quantify efficacy, the divertors were implanted in a compliant elastomeric model of an elastase-induced aneurysm model in rabbit and intra-aneurysmal flow changes were evaluated by particle image velocimetry (PIV). PIV results indicate a marked reduction in intra-aneurysmal-flow activity after divertor implantation in the innominate artery across the aneurysm neck. The mean hydrodynamic circulation after divertor implantation was reduced to 14% or less of the mean circulation in the control and the mean intraaneurysmal kinetic energy was reduced to 29% or less of its value in the control. The intra-aneurysmal wall shear rate in this model is low and implantation of the flow divertor did not change the wall shear rate magnitude appreciably. This in vitro experiment evaluates the characteristics of local low phenomena such as hydrodynamic circulation, kinetic energy, wall shear rate, perforator flow, and changes of these parameters as a result of implantation of stentlike flow divertors in an elastomeric replica of elastase-induced saccular aneurysm model in rabbit. These initial findings offer a database for evaluation of in vivo implantations of such devices in the animal model and help in further development of cerebral aneurysm bypass devices.
引用
收藏
页码:863 / 872
页数:10
相关论文
共 50 条
  • [41] No Effect of Hypercholesterolemia on Elastase-Induced Experimental Abdominal Aortic Aneurysm Progression
    Ikezoe, Toru
    Shoji, Takahiro
    Guo, Jia
    Shen, Fanru
    Lu, Hong S.
    Daugherty, Alan
    Nunokawa, Masao
    Kubota, Hiroshi
    Miyata, Masaaki
    Xu, Baohui
    Dalman, Ronald L.
    BIOMOLECULES, 2021, 11 (10)
  • [42] Measurement of quantifiable parameters by time-density curves in the elastase-induced aneurysm model: first results in the comparison of a flow diverter and a conventional aneurysm stent
    Tobias Struffert
    Sabine Ott
    Markus Kowarschik
    Frederik Bender
    Edyta Adamek
    Tobias Engelhorn
    Philipp Gölitz
    Stefan Lang
    Charles M. Strother
    Arnd Doerfler
    European Radiology, 2013, 23 : 521 - 527
  • [43] The Derivo Embolization Device, a Second-Generation Flow Diverter for the Treatment of Intracranial Aneurysms, Evaluated in an Elastase-Induced Aneurysm Model
    Ley, D.
    Muehl-Benninghaus, R.
    Yilmaz, U.
    Koerner, H.
    Cattaneo, G. F. M.
    Mailaender, W.
    Kim, Y-J.
    Scheller, B.
    Reith, W.
    Simgen, A.
    CLINICAL NEURORADIOLOGY, 2017, 27 (03) : 335 - 343
  • [44] Measurement of quantifiable parameters by time-density curves in the elastase-induced aneurysm model: first results in the comparison of a flow diverter and a conventional aneurysm stent
    Struffert, Tobias
    Ott, Sabine
    Kowarschik, Markus
    Bender, Frederik
    Adamek, Edyta
    Engelhorn, Tobias
    Goelitz, Philipp
    Lang, Stefan
    Strother, Charles M.
    Doerfler, Arnd
    EUROPEAN RADIOLOGY, 2013, 23 (02) : 521 - 527
  • [45] Rabbit aneurysm model mediated by the application of elastase
    Sasaki, K
    Ujiie, H
    Higa, T
    Hori, T
    Shinya, N
    Uchida, T
    NEUROLOGIA MEDICO-CHIRURGICA, 2004, 44 (09) : 467 - 473
  • [46] Vascular smooth muscle cell remodelling in elastase-induced aortic aneurysm
    Jiao, Lei
    Xu, Zheng
    Xu, Feng
    Zhang, Shiming
    Wu, Kaiyun
    ACTA CARDIOLOGICA, 2010, 65 (05) : 499 - 506
  • [47] Elastase-induced matrix degradation in arterial organ cultures: An in vitro model of aneurysmal disease
    Wills, A
    Thompson, MM
    Crowther, M
    Brindle, NP
    Nasim, A
    Sayers, RD
    Bell, PRF
    JOURNAL OF VASCULAR SURGERY, 1996, 24 (04) : 667 - 679
  • [48] CONTRACTILE AND HISTOCHEMICAL-CHARACTERISTICS OF THE RABBIT DIAPHRAGM IN ELASTASE-INDUCED EMPHYSEMA
    DELPIERRE, S
    FORNARIS, M
    PELISSIER, JF
    PAYAN, MJ
    LUNG, 1985, 163 (04) : 221 - 232
  • [49] Differential Expression of Genes in Elastase-Induced Saccular Aneurysms With High and Low Aspect Ratios COMMENTS
    Macdonald, R. Loch
    Yeoh, H. Kwang
    Dumont, Aaron S.
    NEUROSURGERY, 2010, 66 (03) : 584 - 584
  • [50] [18F]Fluorothymidine Uptake in the Porcine Pancreatic Elastase-Induced Model of Abdominal Aortic Aneurysm
    Gandhi, Richa
    Koch-Paszkowski, Joanna
    Tsoumpas, Charalampos
    Bailey, Marc A.
    JOURNAL OF IMAGING, 2021, 7 (08)