In vitro evaluation of flow divertors in an elastase-induced saccular aneurysm model in rabbit

被引:63
|
作者
Seong, Jaehoon [1 ]
Wakhloo, Ajay K. [2 ]
Lieber, Baruch B. [1 ,3 ]
机构
[1] Univ Miami, Dept Biomed Engn, Coral Gables, FL 33146 USA
[2] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
[3] Univ Miami, Dept Radiol, Coral Gables, FL 33146 USA
关键词
elastase-induced saccular aneurysm; PIV; flow divertor; silicone replica; intra-aneurysmal flow;
D O I
10.1115/1.2800787
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Endovascular coiling is an acceptable treatment of intracranial aneurysms, yet long term follow-ups suggest that endovascular coiling fails to achieve complete aneurysm occlusions particularly in wide-neck and giant aneurysms. Placing of a stentlike device across the aneurysm neck may be sufficient to occlude the aneurysm by promoting intra-aneurysmal thrombosis; however, conclusive evidence of its efficacy is still lacking. In this study, we investigate in vitro the efficacy of custom designed flow divertors that will be subsequently implanted in a large cohort of animals. The aim of this study is to provide a detailed database against which in vivo results can be analyzed. Six custom designed flow divertors were fabricated and tested in vitro. The design matrix included three different porosities (75%, 70%, and 65%). For each porosity, there were two divertors with one having a nominal pore density double than that of the other. To quantify efficacy, the divertors were implanted in a compliant elastomeric model of an elastase-induced aneurysm model in rabbit and intra-aneurysmal flow changes were evaluated by particle image velocimetry (PIV). PIV results indicate a marked reduction in intra-aneurysmal-flow activity after divertor implantation in the innominate artery across the aneurysm neck. The mean hydrodynamic circulation after divertor implantation was reduced to 14% or less of the mean circulation in the control and the mean intraaneurysmal kinetic energy was reduced to 29% or less of its value in the control. The intra-aneurysmal wall shear rate in this model is low and implantation of the flow divertor did not change the wall shear rate magnitude appreciably. This in vitro experiment evaluates the characteristics of local low phenomena such as hydrodynamic circulation, kinetic energy, wall shear rate, perforator flow, and changes of these parameters as a result of implantation of stentlike flow divertors in an elastomeric replica of elastase-induced saccular aneurysm model in rabbit. These initial findings offer a database for evaluation of in vivo implantations of such devices in the animal model and help in further development of cerebral aneurysm bypass devices.
引用
收藏
页码:863 / 872
页数:10
相关论文
共 50 条
  • [31] Rapid saccular aneurysm induction by elastase application in vitro - Comment
    Guglielmi, G
    NEUROSURGERY, 1997, 41 (01) : 228 - 228
  • [33] A Rat Model of Elastase-Induced Emphysema
    Lieber, G.
    Jimenez, J.
    Smith, K. R.
    Chapman, R. W.
    McLeod, R. L.
    Jia, Y.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [34] Serial angiography in an elastase-induced aneurysm model in rabbits: Evidence for progressive aneurysm enlargement after creation
    Fujiwara, NH
    Cloft, HJ
    Marx, WF
    Short, JG
    Jensen, ME
    Kallmes, DF
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (04) : 698 - 703
  • [35] Treatment of Rabbit Elastase-Induced Aneurysm Models by Flow Diverters: Development of Quantifiable Indexes of Device Performance Using Digital Subtraction Angiography
    Sadasivan, Chander
    Cesar, Liliana
    Seong, Jaehoon
    Wakhloo, Ajay K.
    Lieber, Baruch B.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (07) : 1117 - 1125
  • [36] Differential Expression of Genes in Elastase-induced Saccular Aneurysms with High and Low Aspect Ratios
    Kadirvel, Ramanathan
    Ding, Yong-Hong
    Dai, Daying
    Zeng, Zijing
    Zakaria, Hasballah
    Robertson, Anne M.
    Lewis, Debra A.
    Kallmes, David F.
    STROKE, 2009, 40 (04) : E166 - E166
  • [37] Elastase-Induced Intracranial Dolichoectasia Model in Mice
    Dai, Daying
    Kadirvel, Ram
    Rezek, Issa
    Ding, Yong-Hong
    Lingineni, Ravi
    Kallmes, David
    NEUROSURGERY, 2015, 76 (03) : 337 - 343
  • [38] Differential Expression of Genes in Elastase-Induced Saccular Aneurysms With High and Low Aspect Ratios
    Kadirvel, Ramanathan
    Ding, Yong-Hong
    Dai, Daying
    Lewis, Debra A.
    Kallmes, David F.
    NEUROSURGERY, 2010, 66 (03) : 578 - 584
  • [39] Elastase-induced saccular aneurysms in rabbits: Comparison of geometric features with those of human aneurysms
    Short, JG
    Fujiwara, NH
    Marx, WE
    Helm, GA
    Cloft, HJ
    Kallmes, DF
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (10) : 1833 - 1837
  • [40] The Derivo Embolization Device, a Second-Generation Flow Diverter for the Treatment of Intracranial Aneurysms, Evaluated in an Elastase-Induced Aneurysm Model
    D. Ley
    R. Mühl-Benninghaus
    U. Yilmaz
    H. Körner
    G. F. M. Cattaneo
    W. Mailänder
    Y-J. Kim
    B. Scheller
    W. Reith
    A. Simgen
    Clinical Neuroradiology, 2017, 27 : 335 - 343