In vitro evaluation of flow divertors in an elastase-induced saccular aneurysm model in rabbit

被引:63
|
作者
Seong, Jaehoon [1 ]
Wakhloo, Ajay K. [2 ]
Lieber, Baruch B. [1 ,3 ]
机构
[1] Univ Miami, Dept Biomed Engn, Coral Gables, FL 33146 USA
[2] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
[3] Univ Miami, Dept Radiol, Coral Gables, FL 33146 USA
关键词
elastase-induced saccular aneurysm; PIV; flow divertor; silicone replica; intra-aneurysmal flow;
D O I
10.1115/1.2800787
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Endovascular coiling is an acceptable treatment of intracranial aneurysms, yet long term follow-ups suggest that endovascular coiling fails to achieve complete aneurysm occlusions particularly in wide-neck and giant aneurysms. Placing of a stentlike device across the aneurysm neck may be sufficient to occlude the aneurysm by promoting intra-aneurysmal thrombosis; however, conclusive evidence of its efficacy is still lacking. In this study, we investigate in vitro the efficacy of custom designed flow divertors that will be subsequently implanted in a large cohort of animals. The aim of this study is to provide a detailed database against which in vivo results can be analyzed. Six custom designed flow divertors were fabricated and tested in vitro. The design matrix included three different porosities (75%, 70%, and 65%). For each porosity, there were two divertors with one having a nominal pore density double than that of the other. To quantify efficacy, the divertors were implanted in a compliant elastomeric model of an elastase-induced aneurysm model in rabbit and intra-aneurysmal flow changes were evaluated by particle image velocimetry (PIV). PIV results indicate a marked reduction in intra-aneurysmal-flow activity after divertor implantation in the innominate artery across the aneurysm neck. The mean hydrodynamic circulation after divertor implantation was reduced to 14% or less of the mean circulation in the control and the mean intraaneurysmal kinetic energy was reduced to 29% or less of its value in the control. The intra-aneurysmal wall shear rate in this model is low and implantation of the flow divertor did not change the wall shear rate magnitude appreciably. This in vitro experiment evaluates the characteristics of local low phenomena such as hydrodynamic circulation, kinetic energy, wall shear rate, perforator flow, and changes of these parameters as a result of implantation of stentlike flow divertors in an elastomeric replica of elastase-induced saccular aneurysm model in rabbit. These initial findings offer a database for evaluation of in vivo implantations of such devices in the animal model and help in further development of cerebral aneurysm bypass devices.
引用
收藏
页码:863 / 872
页数:10
相关论文
共 50 条
  • [21] Establishment of a New Murine Elastase-Induced Aneurysm Model Combined with Transplantation
    Rowinska, Zuzanna
    Gorressen, Simone
    Merx, Marc W.
    Koeppel, Thomas A.
    Liehn, Elisa A.
    Zernecke, Alma
    PLOS ONE, 2014, 9 (07):
  • [22] Hemodynamics and Anatomy of Elastase-Induced Rabbit Aneurysm Models: Similarity to Human Cerebral Aneurysms?
    Zeng, Z.
    Kallmes, D. F.
    Durka, M. J.
    Ding, Y.
    Lewis, D.
    Kadirvel, R.
    Robertson, A. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (03) : 595 - 601
  • [23] Long-term patency of elastase-induced aneurysm model in rabbits
    Ding, YH
    Dai, D
    Lewis, DA
    Danielson, MA
    Kadirvel, R
    Cloft, HJ
    Kallmes, DF
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (01) : 139 - 141
  • [24] Adaptive Remodeling in the Elastase-Induced Rabbit Aneurysms
    Sang, C.
    Kallmes, D. F.
    Kadirvel, R.
    Durka, M. J.
    Ding, Y-H
    Dai, D.
    Watkins, S. C.
    Robertson, A. M.
    EXPERIMENTAL MECHANICS, 2021, 61 (01) : 263 - 283
  • [25] Adaptive Remodeling in the Elastase-Induced Rabbit Aneurysms
    C. Sang
    D. F. Kallmes
    R. Kadirvel
    M. J. Durka
    Y.-H. Ding
    D. Dai
    S. C. Watkins
    A. M. Robertson
    Experimental Mechanics, 2021, 61 : 263 - 283
  • [26] Evaluation of a newly designed flow diverter for the treatment of intracranial aneurysms in an elastase-induced aneurysm model, in New Zealand white rabbits
    Simgen, Andreas
    Ley, Desiree
    Roth, Christian
    Yilmaz, Umut
    Koerner, Heiko
    Muehl-Benninghaus, Ruben
    Kim, Yoo-Jin
    Scheller, Bruno
    Reith, Wolfgang
    NEURORADIOLOGY, 2014, 56 (02) : 129 - 137
  • [27] Evaluation of a newly designed flow diverter for the treatment of intracranial aneurysms in an elastase-induced aneurysm model, in New Zealand white rabbits
    Andreas Simgen
    Desiree Ley
    Christian Roth
    Umut Yilmaz
    Heiko Körner
    Ruben Mühl-Benninghaus
    Yoo-Jin Kim
    Bruno Scheller
    Wolfgang Reith
    Neuroradiology, 2014, 56 : 129 - 137
  • [28] A proposed ordinal scale for grading histology in elastase-induced, saccular aneurysms
    Dai, D
    Ding, YH
    Lewis, DA
    Kallmes, DF
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (01) : 132 - 138
  • [29] Elastase-induced saccular aneurysms in rabbits: A dose-escalation study
    Kallmes, DF
    Fujiwara, NH
    Berr, SS
    Helm, GA
    Cloft, HJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (02) : 295 - 298
  • [30] Arterial saccular aneurysm model in the rabbit
    Cawley, CM
    Dawson, RC
    Shengelaia, G
    Bonner, G
    Barrow, DL
    Colohan, ART
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (09) : 1761 - 1766