Impact of Time-of-Flight PET on Whole-Body Oncologic Studies: A Human Observer Lesion Detection and Localization Study

被引:79
|
作者
Surti, Suleman [1 ]
Scheuermann, Joshua [1 ]
El Fakhri, Georges [2 ,3 ]
Daube-Witherspoon, Margaret E. [1 ]
Lim, Ruth [2 ,3 ]
Abi-Hatem, Nathalie [2 ,3 ]
Moussallem, Elie [2 ,3 ]
Benard, Francois [4 ]
Mankoff, David [5 ]
Karp, Joel S. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Harvard Univ, Sch Med, Dept Radiol, Div Nucl Med & Mol Imaging, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Boston, MA 02114 USA
[4] BC Canc Res Ctr, Dept Mol Oncol, Vancouver, BC, Canada
[5] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
基金
美国国家卫生研究院;
关键词
lesion detection; human observers; LROC; time-of-flight PET; PERFORMANCE; SCANNER; BENEFIT;
D O I
10.2967/jnumed.110.086678
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Phantom studies have shown improved lesion detection performance with time-of-flight (TOF) PET. In this study, we evaluate the benefit of fully 3-dimensional, TOF PET in clinical whole-body oncology using human observers to localize and detect lesions in realistic patient anatomic backgrounds. Our hypothesis is that with TOF imaging we achieve improved lesion detection and localization for clinically challenging tasks, with a bigger impact in large patients. Methods: One hundred patient studies with normal (18)F-FDG uptake were chosen. Spheres (diameter, 10 mm) were imaged in air at variable locations in the scanner field of view corresponding to lung and liver locations within each patient. Sphere data were corrected for attenuation and merged with patient data to produce fused list-mode data files with lesions added to normal-uptake scans. All list files were reconstructed with full corrections and with or without the TOF kernel using a list-mode iterative algorithm. The images were presented to readers to localize and report the presence or absence of a lesion and their confidence level. The interpretation results were then analyzed to calculate the probability of correct localization and detection, and the area under the localized receiver operating characteristic (LROC) curve. The results were analyzed as a function of scan time per bed position, patient body mass index (BMI < 26 and BMI >= 26), and type of imaging (TOF and non-TOF). Results: Our results showed that longer scan times led to an improved area under the LROC curve for all patient sizes. With TOF imaging, there was a bigger increase in the area under the LROC curve for larger patients (BMI > 26). Finally, we saw smaller differences in the area under the LROC curve for large and small patients when longer scan times were combined with TOF imaging. Conclusion: A combination of longer scan time (3 min in this study) and TOF imaging provides the best performance for imaging large patients or a low-uptake lesion in small or large patients. This imaging protocol also provides similar performance for all patient sizes for lesions in the same organ type with similar relative uptake, indicating an ability to provide a uniform clinical diagnosis in most oncologic lesion detection tasks.
引用
收藏
页码:712 / 719
页数:8
相关论文
共 50 条
  • [41] ROC and localization ROC analyses of lesion detection in whole-body FDG PET: Effects of acquisition mode, attenuation correction and reconstruction algorithm
    Farquhar, TH
    Llacer, J
    Hoh, CK
    Czernin, J
    Gambhir, SS
    Seltzer, MA
    Silverman, DHS
    Qi, JY
    Hsu, CH
    Hoffman, EJ
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (12) : 2043 - 2052
  • [42] Correction to: impact of time-of-flight PET on quantification accuracy and lesion detection in simultaneous 18F-choline PET/MRI for prostate cancer
    Urs J. Muehlematter
    Hannes W. Nagel
    Anton Becker
    Julian Mueller
    Kerstin N. Vokinger
    Felipe de Galiza Barbosa
    Edwin E. G. T. ter Voert
    Patrick Veit-Haibach
    Irene A. Burger
    EJNMMI Research, 8
  • [43] Impact of respiratory motion correction on the detection of small lesions in whole-body PET imaging: a simulation study
    Marache-Francisco, S.
    Lamare, F.
    Fayad, H.
    Visvikis, D.
    Prost, R.
    Rouet, J. -M.
    Lartizien, C.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3531 - 3533
  • [44] Impact of partial volume correction in whole-body PET imaging: a computer-aided detection study
    Lartizien, C.
    Marache-Francisco, S.
    Le Pogam, A.
    Tomei, S.
    Visvikis, D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3214 - +
  • [45] Impact of acquisition geometry, image processing, and patient size on lesion detection in whole-body 18F-FDG PET
    El Fakhri, Georges
    Santos, Paula A.
    Badawi, Ramsey D.
    Holdsworth, Clay H.
    Van den Abbeele, Annick D.
    Kijewski, Marie Foley
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (12) : 1951 - 1960
  • [46] Relative benefit of time-of-flight (TOF) and point spread function (PSF) modeling in PET reconstruction: A lesion detection study
    Schaefferkoetter, Joshua
    Townsend, David
    Fu, Yitong
    Wells, Karen
    Bradley, Yong
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [47] Easy detection of tumor in oncologic whole-body PET by projection reconstruction images with maximum intensity projection algorithm
    Fujiwara, T
    Miyake, M
    Watanuki, S
    Mejia, MA
    Itoh, M
    Fukuda, H
    ANNALS OF NUCLEAR MEDICINE, 1999, 13 (03) : 199 - 203
  • [48] Easy detection of tumor in oncologic whole-body PET by projection reconstruction images with maximum intensity projection algorithm
    Takehiko Fujiwara
    Masayasu Miyake
    Shoichi Watanuki
    Marco A. Mejia
    Masatoshi Itoh
    Hiroshi Fukuda
    Annals of Nuclear Medicine, 1999, 13 : 199 - 203
  • [49] Impact of acquisition geometry and patient habitus on lesion detectability in whole body FDG-PET: A channelized hotelling observer study
    El Fakhri, G
    Holdsworth, C
    Badawi, RD
    Santos, PA
    Moore, SC
    Van den Abbeele, AD
    Kijewski, MF
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1402 - 1405
  • [50] Prospective Evaluation of Whole-Body MRI versus FDG PET/CT for Lesion Detection in Participants with Myeloma
    Messiou, Christina
    Porta, Nuria
    Sharma, Bhupinder
    Levine, Daniel
    Koh, Dow-Mu
    Boyd, Kevin
    Pawlyn, Charlotte
    Riddell, Angela
    Downey, Katherine
    Croft, James
    Morgan, Veronica
    Stern, Simon
    Cheung, Betty
    Kyriakou, Charalampia
    Kaczmarek, Pawel
    Winfield, Jessica
    Blackledge, Matthew
    Oyen, Wim J. G.
    Kaiser, Martin F.
    RADIOLOGY-IMAGING CANCER, 2021, 3 (05):