Impact of Time-of-Flight PET on Whole-Body Oncologic Studies: A Human Observer Lesion Detection and Localization Study

被引:79
|
作者
Surti, Suleman [1 ]
Scheuermann, Joshua [1 ]
El Fakhri, Georges [2 ,3 ]
Daube-Witherspoon, Margaret E. [1 ]
Lim, Ruth [2 ,3 ]
Abi-Hatem, Nathalie [2 ,3 ]
Moussallem, Elie [2 ,3 ]
Benard, Francois [4 ]
Mankoff, David [5 ]
Karp, Joel S. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Harvard Univ, Sch Med, Dept Radiol, Div Nucl Med & Mol Imaging, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Boston, MA 02114 USA
[4] BC Canc Res Ctr, Dept Mol Oncol, Vancouver, BC, Canada
[5] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
基金
美国国家卫生研究院;
关键词
lesion detection; human observers; LROC; time-of-flight PET; PERFORMANCE; SCANNER; BENEFIT;
D O I
10.2967/jnumed.110.086678
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Phantom studies have shown improved lesion detection performance with time-of-flight (TOF) PET. In this study, we evaluate the benefit of fully 3-dimensional, TOF PET in clinical whole-body oncology using human observers to localize and detect lesions in realistic patient anatomic backgrounds. Our hypothesis is that with TOF imaging we achieve improved lesion detection and localization for clinically challenging tasks, with a bigger impact in large patients. Methods: One hundred patient studies with normal (18)F-FDG uptake were chosen. Spheres (diameter, 10 mm) were imaged in air at variable locations in the scanner field of view corresponding to lung and liver locations within each patient. Sphere data were corrected for attenuation and merged with patient data to produce fused list-mode data files with lesions added to normal-uptake scans. All list files were reconstructed with full corrections and with or without the TOF kernel using a list-mode iterative algorithm. The images were presented to readers to localize and report the presence or absence of a lesion and their confidence level. The interpretation results were then analyzed to calculate the probability of correct localization and detection, and the area under the localized receiver operating characteristic (LROC) curve. The results were analyzed as a function of scan time per bed position, patient body mass index (BMI < 26 and BMI >= 26), and type of imaging (TOF and non-TOF). Results: Our results showed that longer scan times led to an improved area under the LROC curve for all patient sizes. With TOF imaging, there was a bigger increase in the area under the LROC curve for larger patients (BMI > 26). Finally, we saw smaller differences in the area under the LROC curve for large and small patients when longer scan times were combined with TOF imaging. Conclusion: A combination of longer scan time (3 min in this study) and TOF imaging provides the best performance for imaging large patients or a low-uptake lesion in small or large patients. This imaging protocol also provides similar performance for all patient sizes for lesions in the same organ type with similar relative uptake, indicating an ability to provide a uniform clinical diagnosis in most oncologic lesion detection tasks.
引用
收藏
页码:712 / 719
页数:8
相关论文
共 50 条
  • [31] Clinical Evaluation of Direct 4D Whole-Body PET Parametric Imaging with Time-of-Flight and Resolution Modeling Capabilities
    Karakatsanis, Nicolas A.
    Mehranian, Abolfazl
    Lodge, Martin A.
    Casey, Michael E.
    Rahmim, Arman
    Zaidi, Habib
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [32] Simultaneous Whole-Body Time-of-Flight 18F-FDG PET/MRI A Pilot Study Comparing SUVmax With PET/CT and Assessment of MR Image Quality
    Iagaru, Andrei
    Mittra, Erik
    Minamimoto, Ryogo
    Jamali, Mehran
    Levin, Craig
    Quon, Andrew
    Gold, Garry
    Herfkens, Robert
    Vasanawala, Shreyas
    Gambhir, Sanjiv Sam
    Zaharchuk, Greg
    CLINICAL NUCLEAR MEDICINE, 2015, 40 (01) : 1 - 8
  • [33] Determination of Accuracy and Precision of Lesion Uptake Measurements in Human Subjects with Time-of-Flight PET
    Daube-Witherspoon, Margaret E.
    Surti, Suleman
    Perkins, Amy E.
    Karp, Joel S.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (04) : 602 - 607
  • [34] Impact of time-of-flight PET on quantification accuracy and lesion detection in simultaneous 18F-choline PET/MRI for prostate cancer
    Urs J. Muehlematter
    Hannes W. Nagel
    Anton Becker
    Julian Mueller
    Kerstin N. Vokinger
    Felipe de Galiza Barbosa
    Edwin E. G. T. ter Voert
    Patrick Veit-Haibach
    Irene A. Burger
    EJNMMI Research, 8
  • [35] Impact of time-of-flight PET on quantification accuracy and lesion detection in simultaneous 18F-choline PET/MRI for prostate cancer
    Muehlematter, Urs J.
    Nagel, Hannes W.
    Becker, Anton
    Mueller, Julian
    Vokinger, Kerstin N.
    Barbosa, Felipe de Galiza
    ter Voert, Edwin E. G. T.
    Veit-Haibach, Patrick
    Burger, Irene A.
    EJNMMI RESEARCH, 2018, 8
  • [36] Comparison of standard uptake values in whole body studies acquired on PET/CT and PET/MR systems with time-of-flight capability.
    Long, James
    Kemp, Brad
    Johnson, Geoffrey
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [37] Whole-Body Single-Bed Time-of-Flight RPC-PET: Simulation of Axial and Planar Sensitivities With NEMA and Anthropomorphic Phantoms
    Crespo, Paulo
    Reis, Joao
    Couceiro, Miguel
    Blanco, Alberto
    Ferreira, Nuno C.
    Marques, Rui Ferreira
    Martins, Paulo
    Fonte, Paulo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (03) : 520 - 529
  • [38] Whole-body single-bed time-of-flight RPC-PET: simulation of axial and planar sensitivities with NEMA and anthropomorphic phantoms
    Crespo, Paulo
    Reis, Joao
    Couceiro, Miguel
    Blanco, Alberto
    Ferreira, Nuno C.
    Marques, Rui Ferreira
    Fonte, Paulo
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3420 - +
  • [39] Effect of time-of-flight on lesion detection in PET/CT: Is it simply an effective sensitivity gain over non-time-of-flight?
    Bai, Chuanyong
    Andreyev, Andriy
    Hu, Zhiqiang
    Zhang, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [40] Numerical observer study of lesion detectability for a long axial field-of-view whole-body PET imager using the PennPET Explorer
    Viswanath, Varsha
    Witherspoon, Margaret E. Daube
    Karp, Joel S.
    Surti, Suleman
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (03):