Easy detection of tumor in oncologic whole-body PET by projection reconstruction images with maximum intensity projection algorithm

被引:5
|
作者
Fujiwara, T
Miyake, M
Watanuki, S
Mejia, MA
Itoh, M
Fukuda, H
机构
[1] Tohoku Univ, Inst Dev Aging & Canc, Dept Med Nucl & Radiobiol, Aoba Ku, Sendai, Miyagi 9808575, Japan
[2] Tohoku Univ, Ctr Cyclotron & Radioisotope, Sendai, Miyagi 9808575, Japan
关键词
whole-body PET; 3D display; maximum intensity projection; cancer study; FDG;
D O I
10.1007/BF03164863
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Whole-body PET scanning for an oncology study produces a large number of transaxial images by data acquisition over multiple bed positions. The sagittal and coronal reformatted images are often used for better understanding of radioisotope distribution. We reduced the number of PET images by calculating projection images and evaluated the merit of additional data processing for the visualization and detection of tumors. After reconstructing whole-body F-18-FDG PET images (6-8 bed positions) of eight cancer patients, antero-posterior and lateral projection images were calculated by the maximum intensity projection (MIP) algorithm, the standard deviation projection (SD) algorithm and the summed voxel projection (SUM) algorithm. The projection images were compared with 2D whole-body images for visualizing foci. The focal uptakes of various positions in original whole-body PET data (294-392 transaxial images) were visualized on only two MIP reformatted images when superimposition of hot spots did not occur. Even if one hot spot was superimposed over the other hot spot, we could recognize the existence of at least one focus and determine the true positions of the hot spots from corresponding transaxial images. The SD image was found inferior for showing a contrast of small foci to the corresponding MIP images in the neck, mediastinum and abdomen. The SUM image failed to visualize many metastatic lesions. MIP is a promising technique for the easy preliminary assessment of tumor distribution in oncologic whole-body PET study.
引用
收藏
页码:199 / 203
页数:5
相关论文
共 50 条
  • [1] Easy detection of tumor in oncologic whole-body PET by projection reconstruction images with maximum intensity projection algorithm
    Takehiko Fujiwara
    Masayasu Miyake
    Shoichi Watanuki
    Marco A. Mejia
    Masatoshi Itoh
    Hiroshi Fukuda
    Annals of Nuclear Medicine, 1999, 13 : 199 - 203
  • [2] Maximum Intensity Projection images review - Is there a role in Cardiac PET/CT?
    Muthu, S.
    Shawgi, M.
    Goldstone, A.
    James, J.
    Arumugam, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S320 - S321
  • [3] Deep Learning-Based Feature Extraction from Whole-Body PET/CT Employing Maximum Intensity Projection Images: Preliminary Results of Lung Cancer Data
    Joonhyung Gil
    Hongyoon Choi
    Jin Chul Paeng
    Gi Jeong Cheon
    Keon Wook Kang
    Nuclear Medicine and Molecular Imaging, 2023, 57 : 216 - 222
  • [4] Deep Learning-Based Feature Extraction from Whole-Body PET/CT Employing Maximum Intensity Projection Images: Preliminary Results of Lung Cancer Data
    Gil, Joonhyung
    Choi, Hongyoon
    Paeng, Jin Chul
    Cheon, Gi Jeong
    Kang, Keon Wook
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 57 (05) : 216 - 222
  • [5] DO MAXIMUM INTENSITY PROJECTION IMAGES TRULY CAPTURE TUMOR MOTION?
    Park, Kwangyoul
    Huang, Long
    Gagne, Havaleh
    Papiez, Lech
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02): : 618 - 625
  • [6] Performance analysis of maximum intensity projection algorithm for display of MRA images
    Sun, Y
    Parker, DL
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (12) : 1154 - 1169
  • [7] Effect of Scan Time on Oncologic Lesion Detection in Whole-Body PET
    Kadrmas, Dan J.
    Oktay, M. Bugrahan
    Casey, Michael E.
    Hamill, James J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1940 - 1947
  • [8] A novel computerized approach to enhancing lung tumor detection in whole-body PET images
    Ying, H
    Zhou, FL
    Shields, AF
    Muzik, O
    Wu, DF
    Heath, EI
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1589 - 1592
  • [9] A Template-based Fast Maximum Intensity Projection Algorithm for Medical Images
    Wei, Liu
    2008 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-5, 2008, : 1908 - 1911
  • [10] Maximum intensity projection images in the detection of simulated pulmonary nodules by spiral CT
    Coakley, FV
    Cohen, MD
    Johnson, MS
    Gonin, R
    Hanna, MP
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (842): : 135 - 140