Easy detection of tumor in oncologic whole-body PET by projection reconstruction images with maximum intensity projection algorithm

被引:5
|
作者
Fujiwara, T
Miyake, M
Watanuki, S
Mejia, MA
Itoh, M
Fukuda, H
机构
[1] Tohoku Univ, Inst Dev Aging & Canc, Dept Med Nucl & Radiobiol, Aoba Ku, Sendai, Miyagi 9808575, Japan
[2] Tohoku Univ, Ctr Cyclotron & Radioisotope, Sendai, Miyagi 9808575, Japan
关键词
whole-body PET; 3D display; maximum intensity projection; cancer study; FDG;
D O I
10.1007/BF03164863
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Whole-body PET scanning for an oncology study produces a large number of transaxial images by data acquisition over multiple bed positions. The sagittal and coronal reformatted images are often used for better understanding of radioisotope distribution. We reduced the number of PET images by calculating projection images and evaluated the merit of additional data processing for the visualization and detection of tumors. After reconstructing whole-body F-18-FDG PET images (6-8 bed positions) of eight cancer patients, antero-posterior and lateral projection images were calculated by the maximum intensity projection (MIP) algorithm, the standard deviation projection (SD) algorithm and the summed voxel projection (SUM) algorithm. The projection images were compared with 2D whole-body images for visualizing foci. The focal uptakes of various positions in original whole-body PET data (294-392 transaxial images) were visualized on only two MIP reformatted images when superimposition of hot spots did not occur. Even if one hot spot was superimposed over the other hot spot, we could recognize the existence of at least one focus and determine the true positions of the hot spots from corresponding transaxial images. The SD image was found inferior for showing a contrast of small foci to the corresponding MIP images in the neck, mediastinum and abdomen. The SUM image failed to visualize many metastatic lesions. MIP is a promising technique for the easy preliminary assessment of tumor distribution in oncologic whole-body PET study.
引用
收藏
页码:199 / 203
页数:5
相关论文
共 50 条
  • [21] New Weighted Maximum Intensity Projection (MIP) Images for Assessing Tumor Motion in the Thorax Without a Respiratory Surrogate
    Pan, T.
    Chang, J.
    Riegel, A.
    Ahmad, M.
    Sun, X.
    Luo, D.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [22] An analytic study of the effects of attenuation on tumor detection in whole-body PET oncology imaging
    Bai, CY
    Kinahan, PE
    Brasse, D
    Cormat, C
    Townsend, DW
    Meltzer, CC
    Villemagne, V
    Charron, M
    Defrise, M
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (11) : 1855 - 1861
  • [23] Advantage of delayed whole-body PET/CT for non-avid tumor detection
    Kim, Sungeun
    Oh, Sang Cheol
    Lee, Sinae
    Cheon, Gi Jeong
    Oh, Sun Young
    Jeong, Eugene
    Choe, Jae Gol
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [24] Maximum intensity projection images for the detection of acute pulmonary emboli with helical CT: Assessment of utility in a porcine model
    Woodard, PK
    Brink, JA
    Horesh, L
    Heiken, JP
    Glazer, HS
    Anderson, DC
    RADIOLOGY, 1996, 201 : 952 - 952
  • [25] Detection and differentiation ability of quick whole-body FDG PET/MRI scan in oncology using a combination of Bayesian penalized likelihood PET reconstruction and abbreviated whole-body MRI
    Inukai, Junko
    Nogami, Munenobu
    Zeng, Feibi
    Kono, Atsushi
    Kubo, Kazuhiro
    Murakami, Takamichi
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [26] Detection of pulmonary nodules with CT: Comparison of axial images, axial maximum intensity projection (MIP) images and a computer aided detection (CAD) system
    De Wever, W
    Kersemans, P
    Bodson, E
    Verschakelen, J
    LUNG CANCER, 2005, 49 : S178 - S179
  • [27] New weighted maximum-intensity-projection images from cine CT for delineation of the lung tumor plus motion
    Pan, Tinsu
    Riegel, Adam C.
    Ahmad, Moiz U.
    Sun, Xiaojun
    Chang, Joe Y.
    Luo, Dershan
    MEDICAL PHYSICS, 2013, 40 (06)
  • [28] Is Automatic Tumor Segmentation on Whole-Body 18F-FDG PET Images a Clinical Reality?
    Sundar, Lalith Kumar Shiyam
    Beyer, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65 (07) : 995 - 997
  • [29] Impact of Time-of-Flight PET on Whole-Body Oncologic Studies: A Human Observer Lesion Detection and Localization Study
    Surti, Suleman
    Scheuermann, Joshua
    El Fakhri, Georges
    Daube-Witherspoon, Margaret E.
    Lim, Ruth
    Abi-Hatem, Nathalie
    Moussallem, Elie
    Benard, Francois
    Mankoff, David
    Karp, Joel S.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (05) : 712 - 719
  • [30] ROC and localization ROC analyses of lesion detection in whole-body FDG PET: Effects of acquisition mode, attenuation correction and reconstruction algorithm
    Farquhar, TH
    Llacer, J
    Hoh, CK
    Czernin, J
    Gambhir, SS
    Seltzer, MA
    Silverman, DHS
    Qi, JY
    Hsu, CH
    Hoffman, EJ
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (12) : 2043 - 2052