Gas chromatographic determination of ethyl glucuronide in hair: Comparison between tandem mass spectrometry and single quadrupole mass spectrometry

被引:25
|
作者
Cappelle, Delphine [1 ]
Neels, Hugo [1 ,2 ]
Yegles, Michel [3 ]
Paulus, Jeff [3 ]
van Nuijs, Alexander L. N. [1 ]
Covaci, Adrian [1 ]
Crunelle, Cleo L. [1 ]
机构
[1] Toxicol Univ Antwerp, B-2610 Antwerp, Belgium
[2] ZNA Stuivenberg Hosp, Toxicol Lab, B-2060 Antwerp, Belgium
[3] Lab Natl Sante, Serv Toxicol, L-3555 Dudelange, Luxembourg
关键词
Ethyl glucuronide; Alcohol; Hair; GC-MS/MS; Negative ion chemical ionization; Validation; ETG;
D O I
10.1016/j.forsciint.2014.11.022
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Ethyl glucuronide (EtG), a minor metabolite of ethanol, accumulates in hair and is currently used as a long-term marker for the detection of chronic and excessive alcohol consumption. Sensitive methods are required to differentiate teetotalers from moderate drinkers according to the established cut-off (i.e., 7 pg/mg hair). The aim of this study was to develop a sensitive method using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) operated in the negative ion chemical ionization (NICI) mode. The validated method was applied to hair samples from teetotalers, moderate and excessive alcohol consumers, and results were compared to a previously validated GC-NICI-MS method. The developed GC-NICI-MS/MS method showed linearity over a range from 2 to 400 pg/mg hair, with a limit of detection (LOD) of 0.05 pg/mg hair and a lower limit of quantification (LLOQ) of 0.2 pg/mg hair, compared to an LOD of 0.5 pg/mg hair and LLOQ of 1.5 pg/mg hair obtained with GC-NICI-MS. Furthermore, lower background noise was observed using GC-NICI-MS/MS. Comparison of results of hair samples (n = 58) obtained by GC-NICI-MS and GC-NICI-MS/MS showed no significant difference between both methods (paired-sample t-test, p > 0.05; mean CV = 1.0%). The differences between both methods were larger for EtG concentrations < 30 mg/pg hair (mean CV = 1.7%) than for EtG concentrations > 30 mg/pg hair (mean CV = 0.7%). This suggests a higher selectivity of GC-NICI-MS/MS at lower concentrations. In conclusion, by using GC-NICI-MS/MS, a higher analytical selectivity and an improved signal to noise ratio, can be achieved. Although GC-NICI-MS would not change the interpretation of the EtG concentrations, the present GC-NICI-MS/MS method should preferentially be used for the determination of EtG in hair, especially when differentiating between teetotalers and moderate drinkers according to the current cut-off (i.e., 7 pg/mg hair). (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:20 / 24
页数:5
相关论文
共 50 条
  • [21] Development and validation of a gas chromatography-negative chemical ionization tandem mass spectrometry method for the determination of ethyl glucuronide in hair and its application to forensic toxicology
    Kharbouche, Hicham
    Sporkert, Frank
    Troxier, Stephanie
    Augsburger, Marc
    Mangin, Patrice
    Staub, Christian
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (23): : 2337 - 2343
  • [22] Microwave assisted extraction for the determination of ethyl glucuronide in urine by gas chromatography-mass spectrometry
    Alvarez Freire, Ivan
    Bermejo Barrera, Ana Maria
    Cid Silva, Purificacion
    Tabernero Duque, Maria Jesus
    Fernandez Gomez, Purificacion
    Lopez Eijo, Patricia
    JOURNAL OF APPLIED TOXICOLOGY, 2008, 28 (06) : 773 - 778
  • [23] Determination of furosine in hair by liquid chromatography tandem mass spectrometry
    Takemura, A
    Muramatsu, S
    Kobayashi, N
    Nakagawa, A
    Kitazawa, E
    Uematsu, T
    BIOMEDICAL CHROMATOGRAPHY, 1997, 11 (01) : 61 - 62
  • [24] Direct determination of the ethanol metabolites ethyl glucuronide and ethyl sulfate in urine by liquid chromatography/electrospray tandem mass spectrometry
    Politi, L
    Morini, L
    Groppi, A
    Poloni, V
    Pozzi, F
    Polettini, A
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (10) : 1321 - 1331
  • [25] Determination of polychlorodibenzo-p-dioxins and polychlorodibenzofurans by gas chromatography/tandem mass spectrometry and gas chromatography/triple mass spectrometry in a quadrupole ion trap
    Helen, C
    Lemasle, M
    Laplanche, A
    Genin, E
    JOURNAL OF MASS SPECTROMETRY, 2001, 36 (05): : 546 - 554
  • [26] Accelerated Extraction and Analysis of Ethyl Glucuronide in Hair by Means of Pressurized Liquid Extraction Followed by Liquid Chromatography-Tandem Mass Spectrometry Determination
    Vincenti, Flaminia
    Montesano, Camilla
    Oliva, Eleonora
    Fanti, Federico
    Vincenti, Marco
    Salomone, Alberto
    Compagnone, Dario
    Curini, Roberta
    Sergi, Manuel
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2021, 45 (09) : 927 - 936
  • [27] Applications of tandem quadrupole mass spectrometry in SIMS
    Leggett, G.J., 1600, (16): : 1 - 12
  • [28] Quantitative determination of trichothecenes in breadsticks by gas chromatography-triple quadrupole tandem mass spectrometry
    Rodriguez-Carrasco, Yelko
    Font, Guillermina
    Carlos Molto, Juan
    Berrada, Houda
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2014, 31 (08): : 1422 - 1430
  • [29] Determination of epoxidized soybean oil by gas chromatography/single quadrupole and tandem mass spectrometry stable isotope dilution assay
    Rothenbacher, Thorsten
    Schwack, Wolfgang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (12) : 1937 - 1943
  • [30] Comparison of analytical approaches for liquid chromatography/mass spectrometry determination of the alcohol biomarker ethyl glucuronide in urine
    Helander, Anders
    Kenan, Naama
    Beck, Olof
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (12) : 1737 - 1743