EEG-MRI Co-registration and Sensor Labeling Using a 3D Laser Scanner

被引:44
|
作者
Koessler, L. [2 ,3 ]
Cecchin, T. [1 ]
Caspary, O. [1 ]
Benhadid, A. [4 ,5 ]
Vespignani, H. [2 ,3 ,6 ]
Maillard, L. [2 ,3 ]
机构
[1] Nancy Univ, IUT, Rue Univ, F-88100 Saint Die, France
[2] Nancy Univ, CNRS, CRAN, Vandoeuvre Les Nancy, France
[3] Univ Nancy, Serv Neurol Ctr Hosp, Nancy, France
[4] Nancy Univ, INSERM, Lab Imagerie Adaptat Diagnost & Interventionnelle, Vandoeuvre Les Nancy, France
[5] Ctr Hosp Univ Nancy, Vandoeuvre Les Nancy, France
[6] Univ Nancy, Fac Med, Vandoeuvre Les Nancy, France
关键词
Multimodal co-registration; Laser scanner; Iterative closest point algorithm; Surface fitting; Brain sources imaging; HIGH-RESOLUTION EEG; AUTOMATIC LOCALIZATION; IMAGES; SURFACE; ELECTRODES; ALIGNMENT; VOLUME;
D O I
10.1007/s10439-010-0230-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper deals with the co-registration of an MRI scan with EEG sensors. We set out to evaluate the effectiveness of a 3D handheld laser scanner, a device that is not widely used for co-registration, applying a semi-automatic procedure that also labels EEG sensors. The scanner acquired the sensors' positions and the face shape, and the scalp mesh was obtained from the MRI scan. A pre-alignment step, using the position of three fiducial landmarks, provided an initial value for co-registration, and the sensors were automatically labeled. Co-registration was then performed using an iterative closest point algorithm applied to the face shape. The procedure was conducted on five subjects with two scans of EEG sensors and one MRI scan each. The mean time for the digitization of the 64 sensors and three landmarks was 53 s. The average scanning time for the face shape was 2 min 6 s for an average number of 5,263 points. The mean residual error of the sensors co-registration was 2.11 mm. These results suggest that the laser scanner associated with an efficient co-registration and sensor labeling algorithm is sufficiently accurate, fast and user-friendly for longitudinal and retrospective brain sources imaging studies.
引用
收藏
页码:983 / 995
页数:13
相关论文
共 50 条
  • [21] Imaging of prostate cancer: a platform for 3D co-registration of in-vivo MRI ex-vivo MRI and pathology
    Orczyk, Clement
    Mikheev, Artem
    Rosenkrantz, Andrew
    Melamed, Jonathan
    Taneja, Samir S.
    Rusinek, Henry
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [22] Co-registration of EEG and MRI data using matching of spline interpolated and MRI-segmented reconstructions of the scalp surface
    Lamm, C
    Windischberger, C
    Leodolter, U
    Moser, E
    Bauer, H
    BRAIN TOPOGRAPHY, 2001, 14 (02) : 93 - 100
  • [23] Co-Registration of EEG and MRI Data Using Matching of Spline Interpolated and MRI-Segmented Reconstructions of the Scalp Surface
    Claus Lamm
    Christian Windischberger
    Ulrich Leodolter
    Ewald Moser
    Herbert Bauer
    Brain Topography, 2001, 14 : 93 - 100
  • [24] Sensor and control electronics for an industrial 3D laser scanner
    Asjes, RJ
    Kooijman, KS
    Vermeulen, OTJA
    Duijve, R
    THREE-DIMENSIONAL AND UNCONVENTIONAL IMAGING FOR INDUSTRIAL INSPECTION AND METROLOGY, 1996, 2599 : 171 - 176
  • [25] 2-D to 3-D refinement of post mortern optical and MRI co-registration
    Kenwright, C
    Bardinet, E
    Hojjat, SA
    Malandain, G
    Ayache, N
    Colchester, ACF
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 935 - 944
  • [26] New 3D Bolton standards: Co-registration of biplane x-rays and 3D CT
    Dean, D
    Subramanyan, K
    Kim, EK
    IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2, 1997, 3034 : 541 - 549
  • [27] A multicenter evaluation of a new method for co-registration of IVUS and 3D angiograms.
    Houissa, K.
    Cruden, N. L.
    Uren, N.
    Escaned, J.
    Macaya, C.
    Slots, T.
    Carlier, S.
    ACTA CARDIOLOGICA, 2016, 71 (01) : 107 - 107
  • [28] 3D co-registration algorithm for catheter-based optical coherence tomography
    Post, Anouk L.
    Cernohorsky, Paul
    Pedrigi, Ryan M.
    Streekstra, Geert J.
    D'Hooghe, Julia N. S.
    Annema, Jouke T.
    Strackee, Simon D.
    Krams, Rob
    van Leeuwen, Ton G.
    de Bruin, Daniel M.
    Faber, Dirk J.
    OSA CONTINUUM, 2020, 3 (10) : 2707 - 2721
  • [29] Development of 3D IVOCT imaging and co-registration of IVOCT and angiography in the catheterization laboratory
    De Cock D.
    Tu S.
    Ughi G.J.
    Adriaenssens T.
    Current Cardiovascular Imaging Reports, 2014, 7 (10)
  • [30] Evaluating error sources to improve precision in the co-registration of underwater 3D models
    Lechene, Marine A. A.
    Figueira, Will F.
    Murray, Nicholas J.
    Aston, Eoghan A.
    Gordon, Sophie E.
    Ferrari, Renata
    ECOLOGICAL INFORMATICS, 2024, 81