Co-registration of EEG and MRI data using matching of spline interpolated and MRI-segmented reconstructions of the scalp surface

被引:22
|
作者
Lamm, C
Windischberger, C
Leodolter, U
Moser, E
Bauer, H
机构
[1] Univ Vienna, Dept Psychol, Brain Res Lab, A-1090 Vienna, Austria
[2] Univ Vienna, Inst Med Phys, NMR Grp, A-1090 Vienna, Austria
[3] Univ Hosp Vienna, Dept Radiodiagnost, A-1090 Vienna, Austria
关键词
co-registration; surface matching; EEG; MRI; brain mapping;
D O I
10.1023/A:1012988728672
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Accurate co-registration of MRI and EEG data is indispensable for the correct interpretation of EEG maps or source localizations in relation to brain anatomy derived from MRI. In this study, a method for the co-registration of EEG and MRI data is presented. The method consists of an iterative matching of EEG-electrode based reconstructions of the scalp surface to scalp-segmented MRIs. EEG-electrode based surface reconstruction is achieved via spline interpolation of individually digitized 3D-electrode coordinates. In contrast to other approaches, neither fiducial determination nor any additional provisions (such as bite bars, other co-registration devices or head shape digitization) are required, and co-registration errors associated with inaccurate fiducial determination are avoided. The accuracy of the method was estimated by calculating the root-mean-square (RMS) deviation of spline interpolated and MRI-segmented surface reconstructions in 20 subjects. In addition, the distance between co-registered and genuine electrode coordinates was assessed via a simulation study, in which surface reconstruction was based on virtual electrodes determined on the scalp surface of a high-resolution MRI data set. The mean RMS deviation of surface reconstructions was 2.43 mm, and the maximal distance between any two matched surface points was 5.06 mm. The simulated co-registration revealed a mean deviation of genuine and co-registered electrode coordinates of 0.61 mm. It is concluded that surface matching using spline interpolated reconstructions of scalp surfaces is a precise and highly practicable method to co-register EEG and MRI data.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 47 条
  • [1] Co-Registration of EEG and MRI Data Using Matching of Spline Interpolated and MRI-Segmented Reconstructions of the Scalp Surface
    Claus Lamm
    Christian Windischberger
    Ulrich Leodolter
    Ewald Moser
    Herbert Bauer
    Brain Topography, 2001, 14 : 93 - 100
  • [2] Optical Co-registration of MRI and On-scalp MEG
    Rasmus Zetter
    Joonas Iivanainen
    Lauri Parkkonen
    Scientific Reports, 9
  • [3] Optical Co-registration of MRI and On-scalp MEG
    Zetter, Rasmus
    Livanainen, Joonas
    Parkkonen, Lauri
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [4] Estimation of the accuracy of a surface matching technique for registration of EEG and MRI data
    Huppertz, HJ
    Otte, M
    Grimm, C
    Kristeva-Feige, R
    Mergner, T
    Lücking, CH
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 106 (05): : 409 - 415
  • [5] Brain surface electrode co-registration using MRI and x-ray
    Miller, Kai J.
    Hebb, Adam O.
    Hermes, Dora
    den Nijs, Marcel
    Ojemann, Jeffrey G.
    Rao, Rajesh P. N.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 6015 - 6018
  • [6] EEG–MRI Co-registration and Sensor Labeling Using a 3D Laser Scanner
    L. Koessler
    T. Cecchin
    O. Caspary
    A. Benhadid
    H. Vespignani
    L. Maillard
    Annals of Biomedical Engineering, 2011, 39 : 983 - 995
  • [7] Evaluation of MRI-MEG/EEG co-registration strategies using Monte Carlo simulation
    Singh, KD
    Holliday, IE
    Furlong, PL
    Harding, GFA
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 102 (02): : 81 - 85
  • [8] Assessment of fiducial markers to enable the co-registration of photographs and MRI data
    Webb, Bridgette A.
    Petrovic, Andreas
    Urschler, Martin
    Scheurer, Eva
    FORENSIC SCIENCE INTERNATIONAL, 2015, 248 : 148 - 153
  • [9] EEG-MRI Co-registration and Sensor Labeling Using a 3D Laser Scanner
    Koessler, L.
    Cecchin, T.
    Caspary, O.
    Benhadid, A.
    Vespignani, H.
    Maillard, L.
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (03) : 983 - 995
  • [10] EEG/MEG source imaging in the absence of subject's brain MRI scan: Perspective on co-registration and MRI selection approach
    Gohel, Bakul
    Khare, Mahish
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2023, 33 (01) : 287 - 298