2-D to 3-D refinement of post mortern optical and MRI co-registration

被引:0
|
作者
Kenwright, C [1 ]
Bardinet, E
Hojjat, SA
Malandain, G
Ayache, N
Colchester, ACF
机构
[1] Univ Kent, Canterbury CT2 7NZ, Kent, England
[2] INRIA, EPIDAURE Res Project, F-06902 Sophia Antipolis, France
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Accurate co-registration of MR images of the brain with pathological data from the same patient is required for many applications, including validation of in-vivo MRI processing. We present preliminary results from a 2-D optical to 3-D MRI registration process, which depends on initialisation using an initial 3-D reconstruction of post-mortem whole-brain or hemisphere slices from independent 2D images followed by 3-D to 3-D registration. Our overall approach progressively models the acquisition process, and the final stages account for variations in slice thickness and other errors that can occur as a result of the specimen preparation and earlier processing. Our method can be used in most neuropathology laboratories where thick slices are cut. Alternative approaches depend on sectioning by macrocryotomes, which are not generally available and have limited applicability in conditions such as CJD where infectivity risks are high.
引用
收藏
页码:935 / 944
页数:10
相关论文
共 50 条
  • [1] 3-D CT and MRI co-registration in the assessment of cochlear implantation
    Neri, E
    Berrettini, S
    Salvatori, L
    Forli, F
    Franceschini, SS
    Bartolozzi, C
    MEDICAL SCIENCE MONITOR, 2005, 11 (10): : MT63 - MT67
  • [2] 3-D/2-D registration by integrating 2-D information in 3-D
    Tomazevic, D
    Likar, B
    Pernus, F
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (01) : 17 - 27
  • [3] Providing visual information to validate 2-D to 3-D registration
    Guéziec, A
    Wu, KN
    Kalvin, A
    Williamson, B
    Kazanzides, P
    Van Vorhis, R
    MEDICAL IMAGE ANALYSIS, 2000, 4 (04) : 357 - 374
  • [4] 3-D–2-D spatiotemporal registration for sports motion analysis
    Wee Kheng Leow
    Ruixuan Wang
    Hon Wai Leong
    Machine Vision and Applications, 2012, 23 : 1177 - 1194
  • [5] Automatic registration of 2-D with 3-D imagery in urban environments
    Stamos, I
    Allen, PK
    EIGHTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOL II, PROCEEDINGS, 2001, : 731 - 736
  • [6] Estimation of 3-D human body posture via co-registration of 3-D human model and sequential stereo information
    Nguyen Duc Thang
    Kim, Tae-Seong
    Lee, Young-Koo
    Lee, Sungyoung
    APPLIED INTELLIGENCE, 2011, 35 (02) : 163 - 177
  • [7] Estimation of 3-D human body posture via co-registration of 3-D human model and sequential stereo information
    Nguyen Duc Thang
    Tae-Seong Kim
    Young-Koo Lee
    Sungyoung Lee
    Applied Intelligence, 2011, 35 : 163 - 177
  • [8] Nonrigid 3-D/2-D registration of images using statistical models
    Fleute, M
    Lavallée, S
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 138 - 147
  • [9] Accuracy of 3D CT/MRI co-registration in planning epilepsy surgery
    Hawes-Ebersole, S
    Tao, JX
    Shah, S
    Baldwin, M
    Erickson, RK
    Ebersole, JS
    EPILEPSIA, 2005, 46 : 241 - 241
  • [10] MORPHING IN 2-D AND 3-D
    HALL, V