2-D to 3-D refinement of post mortern optical and MRI co-registration

被引:0
|
作者
Kenwright, C [1 ]
Bardinet, E
Hojjat, SA
Malandain, G
Ayache, N
Colchester, ACF
机构
[1] Univ Kent, Canterbury CT2 7NZ, Kent, England
[2] INRIA, EPIDAURE Res Project, F-06902 Sophia Antipolis, France
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Accurate co-registration of MR images of the brain with pathological data from the same patient is required for many applications, including validation of in-vivo MRI processing. We present preliminary results from a 2-D optical to 3-D MRI registration process, which depends on initialisation using an initial 3-D reconstruction of post-mortem whole-brain or hemisphere slices from independent 2D images followed by 3-D to 3-D registration. Our overall approach progressively models the acquisition process, and the final stages account for variations in slice thickness and other errors that can occur as a result of the specimen preparation and earlier processing. Our method can be used in most neuropathology laboratories where thick slices are cut. Alternative approaches depend on sectioning by macrocryotomes, which are not generally available and have limited applicability in conditions such as CJD where infectivity risks are high.
引用
收藏
页码:935 / 944
页数:10
相关论文
共 50 条
  • [31] 2-D PHYSICS AND 3-D TOPOLOGY
    CRANE, L
    COMMUNICATIONS IN MATHEMATICAL PHYSICS, 1991, 135 (03) : 615 - 640
  • [32] Colour perception in 2-D and 3-D
    Hedrich, M.
    Bloj, M.
    Ruppertsberg, A.
    PERCEPTION, 2007, 36 : 193 - 193
  • [33] Exploiting 2-D to 3-D intra-operative image registration for qualitative evaluations and post-operative simulations
    Guéziec, A
    Wu, KN
    Williamson, B
    Kazanzides, P
    Van Vorhis, R
    Kalvin, A
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 820 - 831
  • [34] External optical probing of 2-D and 3-D photonic crystals.
    van Driel, HM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U246 - U246
  • [35] 3D co-registration algorithm for catheter-based optical coherence tomography
    Post, Anouk L.
    Cernohorsky, Paul
    Pedrigi, Ryan M.
    Streekstra, Geert J.
    D'Hooghe, Julia N. S.
    Annema, Jouke T.
    Strackee, Simon D.
    Krams, Rob
    van Leeuwen, Ton G.
    de Bruin, Daniel M.
    Faber, Dirk J.
    OSA CONTINUUM, 2020, 3 (10) : 2707 - 2721
  • [36] 3-D multimodal cardiac data superimposition using 2-D image registration and 3-D reconstruction from multiple views
    Daul, Christian
    Lopez-Hernandez, Juan
    Wolf, Didier
    Karcher, Gilles
    Ethevenot, Gerard
    IMAGE AND VISION COMPUTING, 2009, 27 (06) : 790 - 802
  • [37] 2-D registration and 3-D shape inference of the retinal fundus from fluorescein images
    Choe, Tae Eun
    Medioni, Gerard
    Cohen, Isaac
    Walsh, Alexander C.
    Sadda, SriniVas R.
    MEDICAL IMAGE ANALYSIS, 2008, 12 (02) : 174 - 190
  • [38] Multi-View Depth-Aware Rigid 2-D/3-D Registration
    Schaffert, Roman
    Wang, Jian
    Fischer, Peter
    Borsdorf, Anja
    Maier, Andreas
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [39] Fast 2-D/3-D registration using a laptop PC with commodity graphics hardware
    Ino, F.
    Gomita, J.
    Kawasaki, Y.
    Hagihara, K.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 53 - 54
  • [40] Implanted Knee Kinematics Analysis by 2-D/3-D Registration Using Particle Filter
    Morita, Kento
    Nii, Manabu
    Imamura, Fumiaki
    Morooka, Takatoshi
    Yoshiya, Shinichi
    Kobashi, Syoji
    2016 JOINT 8TH INTERNATIONAL CONFERENCE ON SOFT COMPUTING AND INTELLIGENT SYSTEMS (SCIS) AND 17TH INTERNATIONAL SYMPOSIUM ON ADVANCED INTELLIGENT SYSTEMS (ISIS), 2016, : 827 - 831