2-D to 3-D refinement of post mortern optical and MRI co-registration

被引:0
|
作者
Kenwright, C [1 ]
Bardinet, E
Hojjat, SA
Malandain, G
Ayache, N
Colchester, ACF
机构
[1] Univ Kent, Canterbury CT2 7NZ, Kent, England
[2] INRIA, EPIDAURE Res Project, F-06902 Sophia Antipolis, France
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Accurate co-registration of MR images of the brain with pathological data from the same patient is required for many applications, including validation of in-vivo MRI processing. We present preliminary results from a 2-D optical to 3-D MRI registration process, which depends on initialisation using an initial 3-D reconstruction of post-mortem whole-brain or hemisphere slices from independent 2D images followed by 3-D to 3-D registration. Our overall approach progressively models the acquisition process, and the final stages account for variations in slice thickness and other errors that can occur as a result of the specimen preparation and earlier processing. Our method can be used in most neuropathology laboratories where thick slices are cut. Alternative approaches depend on sectioning by macrocryotomes, which are not generally available and have limited applicability in conditions such as CJD where infectivity risks are high.
引用
收藏
页码:935 / 944
页数:10
相关论文
共 50 条
  • [41] Pairwise domain adaptation module for CNN-based 2-D/3-D registration
    Zheng, Jiannan
    Miao, Shun
    Wang, Z. Jane
    Liao, Rui
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (02)
  • [42] 2-D/3-D Image Registration of Implanted Knee DR Images with Kalman Filter
    Nakajima, Yusuke
    Kobashi, Syoji
    Tsumori, Yohei
    Shimanuma, Nao
    Imawaki, Seturo
    Yoshiya, Shinichi
    Hata, Yutaka
    2009 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC 2009), VOLS 1-9, 2009, : 1107 - +
  • [43] 2-D/3-D Medical Image Registration Based on Feature-Point Matching
    Si, Shengyuan
    Li, Zheng
    Lin, Ze
    Xu, Xian
    Zhang, Yudong
    Xie, Shipeng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [44] Registration of 3-D CT and 2-d flat images of mouse via affine transformation
    Xia, Zheng
    Huang, Xishi
    Zhou, Xiaobo
    Sun, Youxian
    Ntziachristos, Vasilis
    Wong, Stephen T. C.
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2008, 12 (05): : 569 - 578
  • [45] A parallel implementation of 2-D/3-D image registration for computer-assisted surgery
    Ino, F
    Kawasaki, Y
    Tashiro, T
    Nakajima, Y
    Sato, Y
    Tamura, S
    Hagihara, K
    11TH INTERNATIONAL CONFERENCE ON PARALLEL AND DISTRIBUTED SYSTEMS WORKSHOPS, VOL II, PROCEEDINGS,, 2005, : 316 - 320
  • [46] GPU Accelerated Generation of Digitally Reconstructed Radiographs for 2-D/3-D Image Registration
    Dorgham, Osama M.
    Laycock, Stephen D.
    Fisher, Mark H.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (09) : 2594 - 2603
  • [47] Performance Analysis of 2-D GRAPPA and Partial Fourier GRAPPA for 3-D MRI
    He, Shan
    Xie, Guoxi
    Chung, Yiu-Cho
    Ding, Yu
    Liu, Xin
    Qiu, Bensheng
    APPLIED MAGNETIC RESONANCE, 2013, 44 (10) : 1199 - 1212
  • [48] Performance Analysis of 2-D GRAPPA and Partial Fourier GRAPPA for 3-D MRI
    Shan He
    Guoxi Xie
    Yiu-Cho Chung
    Yu Ding
    Xin Liu
    Bensheng Qiu
    Applied Magnetic Resonance, 2013, 44 : 1199 - 1212
  • [49] EEG-MRI Co-registration and Sensor Labeling Using a 3D Laser Scanner
    Koessler, L.
    Cecchin, T.
    Caspary, O.
    Benhadid, A.
    Vespignani, H.
    Maillard, L.
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (03) : 983 - 995
  • [50] Proposal for a new MEG-MRI co-registration: A 3D laser scanner system
    Hironaga, Naruhito
    Hagiwara, Koichi
    Ogata, Katsuya
    Hayamizu, Mariko
    Urakawa, Tomokazu
    Tobimatsu, Shozo
    CLINICAL NEUROPHYSIOLOGY, 2014, 125 (12) : 2404 - 2412