Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences

被引:22
|
作者
Kyriazi, Stavroula [1 ,2 ,3 ]
Blackledge, Matthew [1 ,2 ,3 ]
Collins, David J. [1 ,2 ,3 ]
deSouza, Nandita M. [1 ,2 ,3 ]
机构
[1] Royal Marsden NHS Fdn Trust, CR UK, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Fdn Trust, EPSRC Canc Imaging Ctr, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Sutton SM2 5PT, Surrey, England
关键词
Diffusion-weighted imaging DWI; Image quality; Artefact; Eddy currents; Distortion; EDDY-CURRENT ARTIFACTS; COEFFICIENT MEASUREMENTS; MRI; REDUCTION; GRADIENT;
D O I
10.1007/s00330-010-1826-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare geometric distortion, signal-to-noise ratio (SNR), apparent diffusion coefficient (ADC), efficacy of fat suppression and presence of artefact between monopolar (Stejskal and Tanner) and bipolar (twice-refocused, eddy-current-compensating) diffusion-weighted imaging (DWI) sequences in the abdomen and pelvis. A semiquantitative distortion index (DI) was derived from the subtraction images with b = 0 and 1,000 s/mm(2) in a phantom and compared between the two sequences. Seven subjects were imaged with both sequences using four b values (0, 600, 900 and 1,050 s/mm(2)) and SNR, ADC for different organs and fat-to-muscle signal ratio (FMR) were compared. Image quality was evaluated by two radiologists on a 5-point scale. DI was improved in the bipolar sequence, indicating less geometric distortion. SNR was significantly lower for all tissues and b values in the bipolar images compared with the monopolar (p < 0.05), whereas FMR was not statistically different. ADC in liver, kidney and sacrum was higher in the bipolar scheme compared to the monopolar (p < 0.03), whereas in muscle it was lower (p = 0.018). Image quality scores were higher for the bipolar sequence (p a parts per thousand currency signaEuro parts per thousand 0.025). Artefact reduction makes the bipolar DWI sequence preferable in abdominopelvic applications, although the trade-off in SNR may compromise ADC measurements in muscle.
引用
收藏
页码:2422 / 2431
页数:10
相关论文
共 50 条
  • [41] Comparison of Diffusion-Weighted MRI Using Single-Shot Echo-Planar Imaging and Split Acquisition of Fast Spin-Echo Signal Imaging, a Non-EPI Technique, in Tumors of the Head and Neck
    van der Hulst, Hedda J.
    Braun, Loes
    Westerink, Bram
    Agrotis, Georgios
    ter Beek, Leon C.
    Tissier, Renaud
    Ahmadian, Milad
    Martens, Roland M.
    Casselman, Jan W.
    Beets-Tan, Regina G. H.
    van den Brekel, Michiel W. M.
    Castelijns, Jonas A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2025, 46 (04) : 774 - 783
  • [42] Intravoxel incoherent motion diffusion-weighted imaging in nasopharyngeal carcinoma: comparison of the turbo spin-echo and echo-planar imaging techniques
    Liu, Yuan
    Hu, Liu
    Qian, Lijuan
    Chen, Manman
    Xu, Si
    Sun, Peng
    Huang, Jing
    Lei, Ziqiao
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 9101 - 9111
  • [43] Comparison of the image quality of turbo spin echo- and echo-planar diffusion-weighted images of the oral cavity
    Hirata, Kenichiro
    Nakaura, Takeshi
    Okuaki, Tomoyuki
    Kidoh, Masafumi
    Oda, Seitaro
    Utsunomiya, Daisuke
    Namimoto, Tomohiro
    Kitajima, Mika
    Nakayama, Hideki
    Yamashita, Yasuyuki
    MEDICINE, 2018, 97 (19)
  • [44] Relevance of b-values in evaluating liver fibrosis:: A study in healthy and cirrhotic subjects using two single-shot spin-echo echo-planar diffusion-weighted sequences
    Girometti, Rossano
    Furlan, Alessandro
    Esposito, Gennaro
    Bazzocchi, Massimo
    Como, Giuseppe
    Soldano, Franca
    Isola, Miriam
    Toniutto, Pierluigi
    Zuiani, Chiara
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (02) : 411 - 419
  • [45] Readout-segmented echo-planar imaging in the evaluation of sinonasal lesions: A comprehensive comparison of image quality in single-shot echo-planar imaging
    Zhao, Menglong
    Liu, Zhuang
    Sha, Yan
    Wang, Shenjiang
    Ye, Xinpei
    Pan, Yucheng
    Wang, Shaoyu
    MAGNETIC RESONANCE IMAGING, 2016, 34 (02) : 166 - 172
  • [46] Comparison of DWI Methods in the Pediatric Brain: PROPELLER Turbo Spin-Echo Imaging Versus Readout-Segmented Echo-Planar Imaging Versus Single-Shot Echo-Planar Imaging
    Kim, Tae-Hyung
    Baek, Moon-Young
    Park, Ji Eun
    Ryu, Young Jin
    Cheon, Jung-Eun
    Kim, In-One
    Choi, Young Hun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (06) : 1352 - 1358
  • [47] Increased-contrast, high-spatial-resolution, diffusion-weighted, spin-echo, echo-planar imaging
    Thompson, MR
    Venkatesan, R
    Kuppusamy, K
    Celik, A
    Lin, WL
    Kido, DK
    Haacke, EM
    RADIOLOGY, 1999, 210 (01) : 253 - 259
  • [48] Comparison of ultrafast half-Fourier single-shot turbo spin-echo sequence with turbo spin-echo sequences for T2-weighted imaging of the female pelvis
    Yamashita, Y
    Tang, Y
    Abe, Y
    Mitsuzaki, K
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1207 - 1212
  • [49] Mediastinal Mass: Assessment with Diffusion-weighted Single Shot Echo-planar MR Imaging
    Razek, Abdel A.
    Elshafeay, M.
    Elhadedy, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [50] Comparison of single-shot east spin-echo and conventional spin-echo sequences for MR imaging of the heart: Initial experience
    Vignaux, OB
    Augui, J
    Coste, J
    Argaud, C
    Le Roux, P
    Carlier, PG
    Duboc, D
    Legmann, P
    RADIOLOGY, 2001, 219 (02) : 545 - 550