Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences

被引:22
|
作者
Kyriazi, Stavroula [1 ,2 ,3 ]
Blackledge, Matthew [1 ,2 ,3 ]
Collins, David J. [1 ,2 ,3 ]
deSouza, Nandita M. [1 ,2 ,3 ]
机构
[1] Royal Marsden NHS Fdn Trust, CR UK, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Fdn Trust, EPSRC Canc Imaging Ctr, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Sutton SM2 5PT, Surrey, England
关键词
Diffusion-weighted imaging DWI; Image quality; Artefact; Eddy currents; Distortion; EDDY-CURRENT ARTIFACTS; COEFFICIENT MEASUREMENTS; MRI; REDUCTION; GRADIENT;
D O I
10.1007/s00330-010-1826-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare geometric distortion, signal-to-noise ratio (SNR), apparent diffusion coefficient (ADC), efficacy of fat suppression and presence of artefact between monopolar (Stejskal and Tanner) and bipolar (twice-refocused, eddy-current-compensating) diffusion-weighted imaging (DWI) sequences in the abdomen and pelvis. A semiquantitative distortion index (DI) was derived from the subtraction images with b = 0 and 1,000 s/mm(2) in a phantom and compared between the two sequences. Seven subjects were imaged with both sequences using four b values (0, 600, 900 and 1,050 s/mm(2)) and SNR, ADC for different organs and fat-to-muscle signal ratio (FMR) were compared. Image quality was evaluated by two radiologists on a 5-point scale. DI was improved in the bipolar sequence, indicating less geometric distortion. SNR was significantly lower for all tissues and b values in the bipolar images compared with the monopolar (p < 0.05), whereas FMR was not statistically different. ADC in liver, kidney and sacrum was higher in the bipolar scheme compared to the monopolar (p < 0.03), whereas in muscle it was lower (p = 0.018). Image quality scores were higher for the bipolar sequence (p a parts per thousand currency signaEuro parts per thousand 0.025). Artefact reduction makes the bipolar DWI sequence preferable in abdominopelvic applications, although the trade-off in SNR may compromise ADC measurements in muscle.
引用
收藏
页码:2422 / 2431
页数:10
相关论文
共 50 条
  • [21] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Hong, Ben-Zu
    Li, Xin-Feng
    Lin, Jian-Qing
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (20) : 6374 - 6380
  • [22] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Ben-Zu Hong
    Xin-Feng Li
    Jian-Qing Lin
    World Journal of Gastroenterology, 2015, (20) : 6374 - 6380
  • [23] Diffusion-weighted imaging in the prostate: an apparent diffusion coefficient comparison of half-Fourier acquisition single-shot turbo spin-echo and echo planar imaging
    Babourina-Brooks, Ben
    Cowin, Gary J.
    Wang, Deming
    MAGNETIC RESONANCE IMAGING, 2012, 30 (02) : 189 - 194
  • [24] Intravoxel Incoherent Motion Diffusion-Weighted Imaging of Lung Cancer: Comparison Between Turbo Spin-Echo and Echo-Planar Imaging
    Wan, Qi
    Lei, Qiang
    Wang, Peng
    Hu, Jianfeng
    Zhang, Tianjing
    Yu, Deng
    Li, Xinchun
    Liang, Changhong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (03) : 334 - 340
  • [25] Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck
    Ryoji Mikayama
    Hidetake Yabuuchi
    Shinjiro Sonoda
    Koji Kobayashi
    Kazuya Nagatomo
    Mitsuhiro Kimura
    Satoshi Kawanami
    Takeshi Kamitani
    Seiji Kumazawa
    Hiroshi Honda
    European Radiology, 2018, 28 : 316 - 324
  • [26] Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck
    Mikayama, Ryoji
    Yabuuchi, Hidetake
    Sonoda, Shinjiro
    Kobayashi, Koji
    Nagatomo, Kazuya
    Kimura, Mitsuhiro
    Kawanami, Satoshi
    Kamitani, Takeshi
    Kumazawa, Seiji
    Honda, Hiroshi
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 316 - 324
  • [27] Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck
    Panyarak, Wannakamon
    Chikui, Toru
    Yamashita, Yasuo
    Kamitani, Takeshi
    Yoshiura, Kazunori
    ACADEMIC RADIOLOGY, 2019, 26 (10) : E305 - E316
  • [28] Single-Shot Turbo Spin-Echo Diffusion-Weighted Imaging for Retinoblastoma: Initial Experience
    de Graaf, P.
    Pouwels, P. J. W.
    Rodjan, F.
    Moll, A. C.
    Imhof, S. M.
    Knol, D. L.
    Sanchez, E.
    van der Valk, P.
    Castelijns, J. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (01) : 110 - 118
  • [29] Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients
    Ichikawa, T
    Haradome, H
    Hachiya, J
    Nitatori, T
    Araki, T
    ABDOMINAL IMAGING, 1999, 24 (05): : 456 - 461
  • [30] Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients
    T. Ichikawa
    H. Haradome
    J. Hachiya
    T. Nitatori
    T. Araki