Comparison of Diffusion-Weighted MRI Using Single-Shot Echo-Planar Imaging and Split Acquisition of Fast Spin-Echo Signal Imaging, a Non-EPI Technique, in Tumors of the Head and Neck

被引:0
|
作者
van der Hulst, Hedda J. [1 ,2 ,5 ]
Braun, Loes [1 ]
Westerink, Bram [1 ]
Agrotis, Georgios [1 ,6 ]
ter Beek, Leon C. [3 ]
Tissier, Renaud [4 ]
Ahmadian, Milad [1 ,2 ,7 ]
Martens, Roland M. [8 ]
Casselman, Jan W. [10 ,11 ]
Beets-Tan, Regina G. H. [1 ,5 ,12 ]
van den Brekel, Michiel W. M. [2 ,9 ]
Castelijns, Jonas A. [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Netherlands Canc Inst, Dept Head & Neck Oncol & Surg, Amsterdam, Netherlands
[3] Netherlands Canc Inst, Dept Clin Phys, Amsterdam, Netherlands
[4] Netherlands Canc Inst, Biostat Unit, Amsterdam, Netherlands
[5] Univ Maastricht, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
[6] Univ Hosp Larissa, Dept Neurosurg, Thessaly, Greece
[7] Univ Amsterdam, Amsterdam Ctr Language & Commun, Amsterdam, Netherlands
[8] Vrije Univ Amsterdam, Amsterdam Univ, Med Ctr, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[9] Vrije Univ Amsterdam, Amsterdam Univ, Dept Oral & Maxillofacial Surg, Med Ctr, Amsterdam, Netherlands
[10] Dalhousie Univ, Dept Radiol, Halifax, NS, Canada
[11] Arizona St Lucas Gent, Dept Radiol, Ghent, Belgium
[12] Univ Southern Denmark, Dept Reg Hlth Res, Odense, Denmark
关键词
COEFFICIENT; LESIONS; DWI; ACCURACY;
D O I
10.3174/ajnr.A8529
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI using single-shot echo-planar imaging (DWI-EPI) is susceptible to distortions around air-filled cavities and dental fillings, typical for the head and neck area. Non-EPI, split acquisition of fast spin-echo signals for diffusion imaging (DW-SPLICE) could reduce these distortions and enhance image quality, thereby potentially improving recurrence assessment in squamous cell carcinoma (SCC) of the head and neck region. This study evaluated whether DW-SPLICE is a viable alternative to DWI-EPI through quantitative and qualitative analyses. MATERIALS AND METHODS: The DW-SPLICE sequence was incorporated into the standard 3T head and neck MRI protocol with DWI-EPI. Retrospective analysis was conducted on 2 subgroups: first benign or malignant lesions, and second, posttreatment SCC recurrence. In both subgroups, image quality and distortion were scored by 2 independent radiologists, blinded to the DWI technique and evaluated using mixed-effect linear models. Lesion ADC values were assessed with interclass correlation and Bland-Altman analyses. The delineation geometric similarity of DWI to T1-weighted postcontrast MRI was evaluated using the DSC before and after registration. Recurrence in posttreatment SCC scans was evaluated by the same 2 radiologists blinded to the DWI technique. Recurrence detection rates were then compared between DW-SPLICE and DWI-EPI using mixed logistic regression at 6 months and 1 year postscan follow-up data. RESULTS: From August 2020 to January 2022, fifty-five benign or malignant lesion scans (55 patients) and 74 posttreatment SCC scans (66 patients) were analyzed. DW-SPLICE scored better on image quality and showed less overall distortion than DWI-EPI (0.04 CONCLUSIONS: DW-SPLICE surpasses DWI-EPI on image distortion and quality and improves diagnostic reliability for detecting recurrent or residual SCC on 3T MRI of the head and neck. Consistent use of 1 method for follow-up is advised, because ADC values are not completely interchangeable. Integrating DW-SPLICE can significantly improve tumor assessments in clinical practice.
引用
收藏
页码:774 / 783
页数:10
相关论文
共 50 条
  • [1] Characterization of focal hepatic lesions on diffusion-weighted MR imaging: Comparison between single-shot echo-planar imaging and single shot fast spin-echo sequence
    Ohgiya, Y
    Gokan, T
    Nobusawa, H
    Hirose, M
    Seino, N
    Munechika, H
    RADIOLOGY, 2001, 221 : 108 - 108
  • [2] Evaluation of Thin-slice Coronal Single-shot Turbo Spin-echo Diffusion-weighted Imaging of the Hand: A Comparison with Conventional Echo-planar Diffusion-weighted Imaging
    Ogawa, Masaki
    Nakagawa, Motoo
    Arai, Nobuyuki
    Kan, Hirohito
    Ohba, Shota
    Shibata, Shunsuke
    Maki, Hiroyuki
    Shibamoto, Yuta
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (04) : 382 - 388
  • [3] Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck
    Ryoji Mikayama
    Hidetake Yabuuchi
    Shinjiro Sonoda
    Koji Kobayashi
    Kazuya Nagatomo
    Mitsuhiro Kimura
    Satoshi Kawanami
    Takeshi Kamitani
    Seiji Kumazawa
    Hiroshi Honda
    European Radiology, 2018, 28 : 316 - 324
  • [4] Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck
    Mikayama, Ryoji
    Yabuuchi, Hidetake
    Sonoda, Shinjiro
    Kobayashi, Koji
    Nagatomo, Kazuya
    Kimura, Mitsuhiro
    Kawanami, Satoshi
    Kamitani, Takeshi
    Kumazawa, Seiji
    Honda, Hiroshi
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 316 - 324
  • [5] Diffusion-weighted MRI in prostate cancer - comparison between single-shot fast spin echo and echo planar imaging sequences
    Kozlowski, Piotr
    Chang, Silvia D.
    Goldenberg, S. Larry
    MAGNETIC RESONANCE IMAGING, 2008, 26 (01) : 72 - 76
  • [6] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108
  • [7] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [8] Diffusion-weighted imaging in the prostate: an apparent diffusion coefficient comparison of half-Fourier acquisition single-shot turbo spin-echo and echo planar imaging
    Babourina-Brooks, Ben
    Cowin, Gary J.
    Wang, Deming
    MAGNETIC RESONANCE IMAGING, 2012, 30 (02) : 189 - 194
  • [9] Assessment of Mediastinal Tumors With Diffusion-Weighted Single-Shot Echo-Planar MRI
    Razek, Ahmed Abdel
    Elmorsy, Ahmed
    Elshafey, Mohsen
    Elhadedy, Tamer
    Hamza, Osama
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 535 - 540
  • [10] Diffusion-weighted imaging of the spinal cord: Interleaved echo-planar imaging is superior to fast spin-echo
    Bammer, R
    Augustin, M
    Prokesch, RW
    Stollberger, R
    Fazekas, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 364 - 373