Comparison of Diffusion-Weighted MRI Using Single-Shot Echo-Planar Imaging and Split Acquisition of Fast Spin-Echo Signal Imaging, a Non-EPI Technique, in Tumors of the Head and Neck

被引:0
|
作者
van der Hulst, Hedda J. [1 ,2 ,5 ]
Braun, Loes [1 ]
Westerink, Bram [1 ]
Agrotis, Georgios [1 ,6 ]
ter Beek, Leon C. [3 ]
Tissier, Renaud [4 ]
Ahmadian, Milad [1 ,2 ,7 ]
Martens, Roland M. [8 ]
Casselman, Jan W. [10 ,11 ]
Beets-Tan, Regina G. H. [1 ,5 ,12 ]
van den Brekel, Michiel W. M. [2 ,9 ]
Castelijns, Jonas A. [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Netherlands Canc Inst, Dept Head & Neck Oncol & Surg, Amsterdam, Netherlands
[3] Netherlands Canc Inst, Dept Clin Phys, Amsterdam, Netherlands
[4] Netherlands Canc Inst, Biostat Unit, Amsterdam, Netherlands
[5] Univ Maastricht, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
[6] Univ Hosp Larissa, Dept Neurosurg, Thessaly, Greece
[7] Univ Amsterdam, Amsterdam Ctr Language & Commun, Amsterdam, Netherlands
[8] Vrije Univ Amsterdam, Amsterdam Univ, Med Ctr, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[9] Vrije Univ Amsterdam, Amsterdam Univ, Dept Oral & Maxillofacial Surg, Med Ctr, Amsterdam, Netherlands
[10] Dalhousie Univ, Dept Radiol, Halifax, NS, Canada
[11] Arizona St Lucas Gent, Dept Radiol, Ghent, Belgium
[12] Univ Southern Denmark, Dept Reg Hlth Res, Odense, Denmark
关键词
COEFFICIENT; LESIONS; DWI; ACCURACY;
D O I
10.3174/ajnr.A8529
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI using single-shot echo-planar imaging (DWI-EPI) is susceptible to distortions around air-filled cavities and dental fillings, typical for the head and neck area. Non-EPI, split acquisition of fast spin-echo signals for diffusion imaging (DW-SPLICE) could reduce these distortions and enhance image quality, thereby potentially improving recurrence assessment in squamous cell carcinoma (SCC) of the head and neck region. This study evaluated whether DW-SPLICE is a viable alternative to DWI-EPI through quantitative and qualitative analyses. MATERIALS AND METHODS: The DW-SPLICE sequence was incorporated into the standard 3T head and neck MRI protocol with DWI-EPI. Retrospective analysis was conducted on 2 subgroups: first benign or malignant lesions, and second, posttreatment SCC recurrence. In both subgroups, image quality and distortion were scored by 2 independent radiologists, blinded to the DWI technique and evaluated using mixed-effect linear models. Lesion ADC values were assessed with interclass correlation and Bland-Altman analyses. The delineation geometric similarity of DWI to T1-weighted postcontrast MRI was evaluated using the DSC before and after registration. Recurrence in posttreatment SCC scans was evaluated by the same 2 radiologists blinded to the DWI technique. Recurrence detection rates were then compared between DW-SPLICE and DWI-EPI using mixed logistic regression at 6 months and 1 year postscan follow-up data. RESULTS: From August 2020 to January 2022, fifty-five benign or malignant lesion scans (55 patients) and 74 posttreatment SCC scans (66 patients) were analyzed. DW-SPLICE scored better on image quality and showed less overall distortion than DWI-EPI (0.04 CONCLUSIONS: DW-SPLICE surpasses DWI-EPI on image distortion and quality and improves diagnostic reliability for detecting recurrent or residual SCC on 3T MRI of the head and neck. Consistent use of 1 method for follow-up is advised, because ADC values are not completely interchangeable. Integrating DW-SPLICE can significantly improve tumor assessments in clinical practice.
引用
收藏
页码:774 / 783
页数:10
相关论文
共 50 条
  • [41] Ultrafast bold fMRI using single-shot spin-echo echo planar imaging
    Boujraf, Said
    Summers, Paul
    Belahsen, Faouzi
    Pruessmann, Klaas
    Kollias, Spyros
    JOURNAL OF MEDICAL PHYSICS, 2009, 34 (01) : 37 - 42
  • [42] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    An, He
    Ma, Xiaodong
    Pan, Ziyi
    Guo, Hua
    Lee, Elaine Yuen Phin
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 1876 - 1884
  • [43] Myocardial perfusion with ultra fast spin-echo single-shot echo-planar-imaging
    Pedro Ferreira
    Peter Gatehouse
    David Firmin
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [44] Spinal cord infarction demonstrated on diffusion-weighted MR imaging with a single-shot fast spin-echo sequence
    Fujikawa, A
    Tsuchiya, K
    Koppera, P
    Aoki, C
    Hachiya, J
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (03) : 415 - 419
  • [45] Comparison of Echo Planar and Turbo Spin Echo Diffusion-Weighted Imaging in Intraoperative MRI
    Thorpe, James C.
    Thust, Stefanie C.
    Gillon, Claire H. M.
    Rowe, Selene
    Swain, Charlotte E.
    MacArthur, Donald C.
    Howarth, Simon P.
    Avula, Shivaram
    Morgan, Paul S.
    Dineen, Rob A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (04) : 1847 - 1857
  • [46] Echo-planar imaging is superior to fast spin-echo diffusion-weighted imaging for cranioplasty using titanium mesh in brain magnetic resonance imaging: a phantom study
    Takatsu, Yasuo
    Yamamura, Kenichiro
    Yamatani, Yuya
    Takahashi, Daisuke
    Yoshida, Rei
    Asahara, Masaki
    Honda, Michitaka
    Miyati, Tosiaki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (01) : 89 - 99
  • [47] Colorectal hepatic metastases: quantitative measurements using single-shot echo-planar diffusion-weighted MR imaging
    Koh, D. M.
    Scurr, E.
    Collins, D. J.
    Pirgon, A.
    Kanber, B.
    Karanjia, N.
    Brown, G.
    Leach, M. O.
    Husband, J. E.
    EUROPEAN RADIOLOGY, 2006, 16 (09) : 1898 - 1905
  • [48] Colorectal hepatic metastases: quantitative measurements using single-shot echo-planar diffusion-weighted MR imaging
    D. M. Koh
    E. Scurr
    D. J. Collins
    A. Pirgon
    B. Kanber
    N. Karanjia
    G. Brown
    M. O. Leach
    J. E. Husband
    European Radiology, 2006, 16 : 1898 - 1905
  • [49] Echo-planar imaging is superior to fast spin-echo diffusion-weighted imaging for cranioplasty using titanium mesh in brain magnetic resonance imaging: a phantom study
    Yasuo Takatsu
    Kenichiro Yamamura
    Yuya Yamatani
    Daisuke Takahashi
    Rei Yoshida
    Masaki Asahara
    Michitaka Honda
    Tosiaki Miyati
    Radiological Physics and Technology, 2022, 15 : 89 - 99
  • [50] Body diffusion-weighted imaging using magnetization prepared single-shot fast spin echo and extended parallel imaging signal averaging
    Gibbons, Eric K.
    Vasanawala, Shreyas S.
    Pauly, John M.
    Kerr, Adam B.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) : 3032 - 3044