Slit-lamp measurement of anterior chamber depth and its agreement with anterior segment optical coherence tomography and Lenstar LS 900 in pseudoexfoliation and normal eyes

被引:4
|
作者
Ray, Vanita Pathak [1 ]
Ramesh, Smitha B. [2 ]
Rathi, Varsha [3 ]
机构
[1] Ctr Sight, Dept Glaucoma, Banjara Hills, Hyderabad, Telangana, India
[2] LV Prasad Eye Inst, Dept Glaucoma, Banjara Hills, Hyderabad, Telangana, India
[3] LV Prasad Eye Inst, GPR Int Ctr Adv Rural Eyecare, Hyderabad, Telangana, India
关键词
ACD; ASOCT; Lenstar LS 900; noncontact technique; pseudoexfoliation; Redmond Smith; slit-lamp anterior chamber depth measurement; EXFOLIATION SYNDROME; PSEUDO-EXFOLIATION; ANGLE-CLOSURE; PREVALENCE; GLAUCOMA;
D O I
10.4103/ijo.IJO_3738_20
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: There is a considerable lack of awareness of slit-lamp measurement of anterior chamber depth (ACD) by the Redmond Smith method (SACD) in present day-to-day clinical practice, which may provide rapid assessment in pseudoexfoliation (PXF) when assessing for angle closure and planning for cataract surgery. This assumes importance not only in outreach clinics but also in the ongoing pandemic caused by the highly contagious novel coronavirus, where social distancing is advocated to contain the spread. We aimed to compare the axial ACD in PXF and normal patients by SACD, and its agreement with the anterior segment optical coherence tomography (ASOCT) and LenstarLS-900. Methods: A prospective comparative observational study was done at a tertiary eye care hospital. A PXF group and a normal group of controls were recruited. All eyes were phakic with normal cornea. Any eye with previous intraocular/refractive surgery and cause of other secondary or uncontrolled glaucoma was excluded. SACD was measured clinically via slit-lamp method and also via ASOCT and Lenstar; agreement between the methodologies was plotted. Results: Fifty patients were recruited in each group. Mean age was 66.82 +/- 4.88 years in PXF patients and 65 +/- 5.46 years in controls (P = 0.2). ACD was found to be greater in controls compared with the PXF patients; this difference was statistically significant (P < 0.001) across all methodologies. A good agreement with narrow 95% limits of agreement was found between these methodologies. Conclusion: Redmond Smith slit-lamp methodology of estimating the axial ACD is recommended as a rapid, quantifiable, noncontact screening technique during routine examination, especially in primary outreach centers, and is also advantageous during the ongoing pandemic by reducing expendable investigations.
引用
收藏
页码:2469 / 2474
页数:6
相关论文
共 50 条
  • [1] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    Sakata, L. M.
    Wong, T. T. L.
    Wong, H-T
    Kumar, R. S.
    Htoon, H. M.
    Aung, H. T.
    He, M.
    Aung, T.
    [J]. EYE, 2010, 24 (04) : 578 - 587
  • [2] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    L M Sakata
    T T L Wong
    H-T Wong
    R S Kumar
    H M Htoon
    H T Aung
    M He
    T Aung
    [J]. Eye, 2010, 24 : 578 - 587
  • [3] SLIT-LAMP MEASUREMENT OF THE ANTERIOR-CHAMBER DEPTH
    DOUTHWAITE, WA
    SPENCE, D
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1986, 70 (03) : 205 - 208
  • [4] ANTERIOR-CHAMBER DEPTH MEASUREMENT USING THE SLIT-LAMP MICROSCOPE
    JACOBS, IH
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1979, 88 (02) : 236 - 238
  • [5] Anterior chamber angle measurement with anterior segment optical coherence tomography: A comparison between slit lamp OCT and Visante OCT
    Leung, Christopher Kai-Shun
    Li, Haitao
    Weinreb, Robert Neal
    Liu, Jing
    Cheung, Carol Yim Lui
    Lai, Ricky Yiu Kwong
    Pang, Chi Pui
    Lam, Dennis Shun Chiu
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) : 3469 - 3474
  • [6] Quantitative assessment of anterior chamber parameters in pigmentary glaucoma using slit-lamp optical coherence tomography
    Dinc, Umut A.
    Kulacoglu, Destan N.
    Oncel, Banu
    Yalvac, Ilgaz Sagdic
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (04) : 702 - 707
  • [7] Vascular Density of the Anterior Segment of the Eye Determined by Optical Coherence Tomography Angiography and Slit-Lamp Photography
    Aicher, Nina Teresa
    Nagahori, Katsuya
    Inoue, Makoto
    Itoh, Yuji
    Hirakata, Akito
    [J]. OPHTHALMIC RESEARCH, 2020, 63 (06) : 572 - 579
  • [8] Slit-lamp-adapted optical coherence tomography of the anterior segment
    H. Hoerauf
    C. Wirbelauer
    C. Scholz
    R. Engelhardt
    P. Koch
    H. Laqua
    R. Birngruber
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2000, 238 : 8 - 18
  • [9] Slit-lamp-adapted optical coherence tomography of the anterior segment
    Hoerauf, H
    Wirbelauer, C
    Scholz, C
    Engelhardt, R
    Koch, P
    Laqua, H
    Birngruber, R
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (01) : 8 - 18
  • [10] Assessment and reproducibility of anterior chamber depth measurement with anterior segment optical coherence tomography compared with immersion ultrasonography
    Nemeth, Gabor
    Vajas, Attila
    Tsorbatzoglou, Alexis
    Kolozsvari, Bence
    Modis, Laszlo, Jr.
    Berta, Andras
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03): : 443 - 447