Quantitative assessment of anterior chamber parameters in pigmentary glaucoma using slit-lamp optical coherence tomography

被引:0
|
作者
Dinc, Umut A. [1 ]
Kulacoglu, Destan N. [2 ]
Oncel, Banu [2 ]
Yalvac, Ilgaz Sagdic [1 ]
机构
[1] Yeditepe Univ, Hosp Eye, Dept Ophthalmol, TR-34349 Istanbul, Turkey
[2] Baskent Univ, Dept Ophthalmol, Istanbul, Turkey
关键词
Anterior segment optical coherence tomography; Pigmentary glaucoma; DISPERSION SYNDROME; ULTRASOUND BIOMICROSCOPY; ANGLE MEASUREMENT; LASER IRIDOTOMY; SEGMENT; INTRAOBSERVER; REPRODUCIBILITY; CONFIGURATION; ACCOMMODATION;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To quantitatively assess the parameters of anterior chamber and angle dimensions by slit-lamp optical coherence tomography (SL-OCT) in eyes with pigmentary glaucoma (PG). METHODS. A total of 18 eyes of 11 patients with PG and 18 eyes of 11 healthy volunteers were included in the study. Anterior chamber depth (ACD), anterior chamber volume (ACV), spur distance (internal horizontal anterior chamber diameter), central corneal thickness (CCT), angle opening distance at 500 pm from the scleral spur (AOD 500), and trabecular iris space area at 500 pm from the sclera! spur (TISA 500) parameters were detected by SL-OCT. The differences of anterior chamber parameters between patients with PG and the control group were analyzed by Mann-Whitney U test. RESULTS. Mean ACD and ACV were measured as 3.28 +/- 0.38 mm and 191.6 +/- 39.7 mm(3) respectively in the PG group. Mean AOD 500 and TISA 500 were 0.88 +/- 0.47 mm and 0.29 +/- 0.15 mm(2) at the nasal angle and 1.14 +/- 0.67 mm and 0.41 +/- 0.23 mm(2) at the temporal angle, respectively. Nasal and temporal angles were 49.83 +/- 11.1 degrees and 53.83 +/- 10.46 degrees. In eyes with PG, the midperipheral iris configuration was found to be considerably concave in 15 eyes (83.3%). Except CCT and spur distance, all anterior chamber dimension and angle parameters detected by SL-OCT were found to be significantly higher in the eyes with PG (Mann-Whitney U test, p<0.05). CONCLUSIONS. SL-OCT provided highly quantitative data on the parameters of anterior chamber and angle dimensions in PG. The evaluation of the anterior segment anatomy using SL-OCT revealed increased anterior chamber dimensions and posterior bowing of the iris consistent with the increase in angle parameters in patients with PG. (Eur J Ophthalmol 2010; 20: 702-07)
引用
收藏
页码:702 / 707
页数:6
相关论文
共 50 条
  • [1] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    Sakata, L. M.
    Wong, T. T. L.
    Wong, H-T
    Kumar, R. S.
    Htoon, H. M.
    Aung, H. T.
    He, M.
    Aung, T.
    [J]. EYE, 2010, 24 (04) : 578 - 587
  • [2] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    L M Sakata
    T T L Wong
    H-T Wong
    R S Kumar
    H M Htoon
    H T Aung
    M He
    T Aung
    [J]. Eye, 2010, 24 : 578 - 587
  • [3] Quantitative assessment of anterior chamber volume using slit-lamp OCT and Pentacam
    Dinc, Umut Asli
    Oncel, Banu
    Gorgun, Ebru
    Alimgil, Levent
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (03) : 411 - 415
  • [4] Assessment of anterior chamber angle using Visante OCT, slit-lamp OCT, and Pentacam
    Dinc, Umut A.
    Oncel, Banu
    Gorgun, Ebru
    Yalvac, Ilgaz S.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (03) : 531 - 537
  • [5] Slit-lamp measurement of anterior chamber depth and its agreement with anterior segment optical coherence tomography and Lenstar LS 900 in pseudoexfoliation and normal eyes
    Ray, Vanita Pathak
    Ramesh, Smitha B.
    Rathi, Varsha
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (09) : 2469 - 2474
  • [6] SLIT-LAMP MEASUREMENT OF THE ANTERIOR-CHAMBER DEPTH
    DOUTHWAITE, WA
    SPENCE, D
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1986, 70 (03) : 205 - 208
  • [7] Vascular Density of the Anterior Segment of the Eye Determined by Optical Coherence Tomography Angiography and Slit-Lamp Photography
    Aicher, Nina Teresa
    Nagahori, Katsuya
    Inoue, Makoto
    Itoh, Yuji
    Hirakata, Akito
    [J]. OPHTHALMIC RESEARCH, 2020, 63 (06) : 572 - 579
  • [8] Multimodal Assessment of Corneal Thinning Using Optical Coherence Tomography, Scheimpflug Imaging, Pachymetry, and Slit-Lamp Examination
    Oatts, Julius T.
    Keenan, Jeremy D.
    Mannis, Tova
    Lietman, Tom M.
    Rose-Nussbaumer, Jennifer
    [J]. CORNEA, 2017, 36 (04) : 425 - 430
  • [9] ANTERIOR-CHAMBER DEPTH MEASUREMENT USING THE SLIT-LAMP MICROSCOPE
    JACOBS, IH
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1979, 88 (02) : 236 - 238
  • [10] A comparative study of optical coherence tomography and slit-lamp based grading of cataract
    Mahil, Aman-Deep Singh
    Saunders, Kathryn
    Richardson, Patrick
    Little, Julie-Anne
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)