Slit-lamp-adapted optical coherence tomography of the anterior segment

被引:105
|
作者
Hoerauf, H
Wirbelauer, C
Scholz, C
Engelhardt, R
Koch, P
Laqua, H
Birngruber, R
机构
[1] Univ Lubeck, Dept Ophthalmol, D-23538 Lubeck, Germany
[2] Med Laser Ctr Lubeck, Lubeck, Germany
关键词
D O I
10.1007/s004170050002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the diagnostic potential of a slit-lamp-adapted optical coherence tomography (OCT) system as an in vivo imaging device for routine clinical examination of the anterior segment of the eve. Patients and methods: In a pilot study, healthy volunteers and patients with different pathologies of the anterior segment were examined with a slit-lamp-adapted OCT system using 100-200 axial scans with 100-Hz line-scan frequency. The scan length is variable up to 7 mm, and the axial depth is 1.5 mm in tissue. Results: The slit-lamp-adapted OCT system allowed direct biomicroscopic imaging of the measured area. Anatomic structures and morphological changes anterior to the attenuating iris pigment epithelium could be visualized with high accuracy, Biometric analyses of the cornea, the chamber angle, the iris and secondary cataract were possible. Complete demonstration of the chamber angle was difficult clue to the backscattering properties of the anterior part of the sclera and the consequent shadowing of the most peripheral part of the iris. Conclusions: Slit-lamp-adapted OCT is a diagnostic tool which allows in vivo microscopic cross-sectional imaging of the anterior segment and precise measurement of ocular structures.
引用
收藏
页码:8 / 18
页数:11
相关论文
共 50 条
  • [1] Slit-lamp-adapted optical coherence tomography of the anterior segment
    H. Hoerauf
    C. Wirbelauer
    C. Scholz
    R. Engelhardt
    P. Koch
    H. Laqua
    R. Birngruber
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2000, 238 : 8 - 18
  • [2] Anterior Segment Variations with Age and Accommodation Demonstrated by Slit-Lamp-Adapted Optical Coherence Tomography
    Yan, Pi-Song
    Lin, Hao-Tian
    Wang, Qi-Lin
    Zhang, Zhen-Pin
    [J]. OPHTHALMOLOGY, 2010, 117 (12) : 2301 - 2307
  • [3] Slit-lamp-adapted optical coherence tomography for assessment of an overhanging filtering bleb
    Prata, Tiago Santos
    De Moraes, Carlos Gustavo V.
    Palmiero, Pat-Michael
    Tello, Celso
    Liebmann, Jeffrey
    Ritch, Robert
    [J]. ACTA OPHTHALMOLOGICA, 2010, 88 (08) : 910 - 911
  • [4] Filtering bleb evaluation with slit-lamp-adapted 1310-nm optical coherence tomography
    Mueller, Maya
    Hoerauf, Hans
    Geerling, Gerd
    Pape, Stefanie
    Winter, Christian
    Huettmann, Gereon
    Birngruber, Reginald
    Laqua, Horst
    [J]. CURRENT EYE RESEARCH, 2006, 31 (11) : 909 - 915
  • [5] Imaging of a traumatic cyclodialysis cleft in a child using slit-lamp-adapted optical coherence tomography
    T S Prata
    P-M Palmiero
    C G V De Moraes
    C Tello
    Z Sbeity
    J Liebmann
    R Ritch
    [J]. Eye, 2009, 23 : 1618 - 1619
  • [6] Imaging of a traumatic cyclodialysis cleft in a child using slit-lamp-adapted optical coherence tomography
    Prata, T. S.
    Palmiero, P-M
    De Moraes, C. G. V.
    Tello, C.
    Sbeity, Z.
    Liebmann, J.
    Ritch, R.
    [J]. EYE, 2009, 23 (07) : 1618 - 1619
  • [7] Imaging of Descemet Membrane Detachment After Trabeculectomy Using Slit-lamp-adapted Optical Coherence Tomography
    Palmiero, Pat-Michael
    Sbeity, Zaher
    Liebmann, Jeffrey
    Ritch, Robert
    [J]. JOURNAL OF GLAUCOMA, 2009, 18 (09) : 643 - 645
  • [8] Slit-lamp-adapted optical coherence tomography of pupillary block after Artisan lens implantation for aphakia
    Hogewind B.F.T.
    Theelen T.
    [J]. International Ophthalmology, 2007, 27 (5) : 337 - 338
  • [9] Real time optical coherence tomography of the anterior segment using hand-held and slit-lamp adapted systems.
    Radhakrishnan, S
    Patil, CA
    Rollins, AM
    Reeves, D
    Lass, JH
    Bardenstein, DS
    Westphal, V
    Roth, JE
    Izatt, JA
    [J]. COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS VI, 2002, 4619 : 227 - 229
  • [10] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    L M Sakata
    T T L Wong
    H-T Wong
    R S Kumar
    H M Htoon
    H T Aung
    M He
    T Aung
    [J]. Eye, 2010, 24 : 578 - 587