Divided target optimization with volumetric modulated arc therapy planning to improve target coverage and homogeneity in lung radiation therapy

被引:0
|
作者
Barik, Bijay Kumar [1 ]
Jena, Julie Priya [2 ]
Sahoo, Dillip Kumar [1 ]
Muraleedharan, Anupam [1 ]
Parida, Santosh Kumar [3 ]
Majumdar, Saroj Kumar Das [1 ]
Barik, Sandip Kumar [1 ]
Das, Deepak Kumar [1 ]
Parida, Dillip Kumar [1 ]
机构
[1] All India Inst Med Sci, Dept Radiotherapy, Bhubaneswar, Odisha, India
[2] HCG Canc Ctr, Kalaburagi, Karnataka, India
[3] Siksha O Anusandhan Univ, Inst Tech Educ & Res, Bhubaneswar, Odisha, India
关键词
CANCER;
D O I
10.1016/j.jmir.2022.06.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate and evaluate the feasibility of a simple modified Divided Planning Target Volume (DPTV) optimization method in radiation therapy planning of lung cancer patients. Methods: A cohort of 15 patients of Non-Small Cell Lung Cancer (13 patients stage III and two patients of stage II) who were previously treated with Concurrent Chemo Radiation Therapy were included in the study. The planning modality was Volumetric Modulated Arc Therapy, and the dose prescription was 60 Gray in 30 fractions. In this study, we attempted to replan by dividing the previous Single Planning Target Volume (SPTV) into a DPTV. All the treatment plans were re-vised and again optimized for DPTV with required dose constraints as in SPTV. The dosimetric parameters that were achieved for target and normal structures were recorded in both the optimization methods. Results: Dosimetric target coverage (D95%) (p-value = 0.0001), dose homogeneity (p-value = 0.0001) and conformity (p-value = 0.044) were improved by the DPTV optimization. The volume of the oesophagus receiving 35 Gy was found to be higher in the DPTV arm (p-value = 0.02) compared to the SPTV arm, but the volume of the oesophagus receiving 50 Gy was found to be similar (p-value = 0.122). Conclusion: In radiation therapy planning of lung cancer, the DPTV optimization method has better dose coverage to the target volume, homogeneity, as well as conformity than the stsndsrd SPTV method. Therefore, the DPTV optimization method can be a simple and efficient alternative to the SPTV method in lung cancer.
引用
收藏
页码:471 / 477
页数:7
相关论文
共 50 条
  • [21] Stereotactic radiation treatment planning with volumetric modulated arc therapy: Impact of duodenal sparing on pancreatic tumor coverage
    Kumar, R.
    Kang, J.
    Herman, J. M.
    Tuli, R.
    Pawlik, T. M.
    Tryggestad, E.
    Smith, K.
    DeWeese, T. L.
    Wong, J.
    Ford, E. C.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2011, 29 (04)
  • [22] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    [J]. MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [23] Off-target-isocentric approach in non-coplanar Volumetric Modulated Arc Therapy (VMAT) planning for lung SBRT treatments
    Kim, Sangroh
    Tseng, Tzu-Chi
    [J]. JOURNAL OF RADIOSURGERY AND SBRT, 2015, 3 (03): : 215 - 224
  • [24] Volumetric Modulated Arc Therapy Versus 4-Field Box Radiation Therapy for Postoperative Gynecologic Cancer: Are They Covering the Same Planning Target Volume Adequately?
    Lukovic, J.
    Patil, N.
    D'Souza, D.
    Millman, B.
    Fakir, H.
    Surry, K.
    Yaremko, B.
    Whiston, F.
    Wong, E.
    Hajdok, G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S422 - S422
  • [25] IS ONE SINGLE ARC SUFFICIENT IN VOLUMETRIC MODULATED ARC THERAPY FOR COMPLEX SHAPED TARGET VOLUMES?
    Guckenberger, M.
    Richter, A.
    Krieger, T.
    Wilbert, J.
    Baier, K.
    Flentje, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S193 - S193
  • [26] Intensity modulated radiation therapy versus volumetric intensity modulated arc therapy
    Rana, Suresh
    [J]. JOURNAL OF MEDICAL RADIATION SCIENCES, 2013, 60 (03): : 81 - 83
  • [27] Evaluation of the Virtual Bolus Technique to Cover the Target Volume in Volumetric Modulated Arc Therapy Planning for Breast Cancer
    Dumane, V. A.
    Green, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E655 - E655
  • [28] Comparative planning of volumetric modulated arc therapy versus intensity modulated radiation therapy and proton beam therapy in anal cancer
    Hansen, J.
    Wilken, E.
    Petersen, J.
    Serup-Hansen, E.
    Spindler, K. -L.
    [J]. ANNALS OF ONCOLOGY, 2016, 27 : 62 - 62
  • [29] Risk of Target Coverage Loss in the Treatment of Synchronous Lung Lesions Via a Single-Isocenter Volumetric Modulate Arc Therapy Stereotactic Body Radiation Therapy
    Critchfield, L.
    Bernard, M.
    Randall, M.
    McGarry, R.
    Pokhrel, D.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E482 - E482
  • [30] A comprehensive formulation for volumetric modulated arc therapy planning
    Nguyen, Dan
    Lyu, Qihui
    Ruan, Dan
    O'Connor, Daniel
    Low, Daniel A.
    Sheng, Ke
    [J]. MEDICAL PHYSICS, 2016, 43 (07) : 4263 - 4272