A comprehensive formulation for volumetric modulated arc therapy planning

被引:17
|
作者
Nguyen, Dan [1 ]
Lyu, Qihui [1 ]
Ruan, Dan [1 ]
O'Connor, Daniel [1 ]
Low, Daniel A. [1 ]
Sheng, Ke [1 ]
机构
[1] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90024 USA
关键词
volumetric modulated arc therapy; non-greedy; non-heuristic; direct aperture optimization; DIRECT APERTURE OPTIMIZATION; RADIATION-THERAPY; SEQUENCING ALGORITHM; IMRT; VMAT; REGULARIZATION; SEGMENTATION; TOMOTHERAPY; DELIVERY;
D O I
10.1118/1.4953832
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Volumetric modulated arc therapy (VMAT) is a widely employed radiation therapy technique, showing comparable dosimetry to static beam intensity modulated radiation therapy (IMRT) with reduced monitor units and treatment time. However, the current VMAT optimization has various greedy heuristics employed for an empirical solution, which jeopardizes plan consistency and quality. The authors introduce a novel direct aperture optimization method for VMAT to overcome these limitations. Methods: The comprehensive VMAT (comVMAT) planning was formulated as an optimization problem with an L2-norm fidelity term to penalize the difference between the optimized dose and the prescribed dose, as well as an anisotropic total variation term to promote piecewise continuity in the fluence maps, preparing it for direct aperture optimization. A level set function was used to describe the aperture shapes and the difference between aperture shapes at adjacent angles was penalized to control MLC motion range. A proximal-class optimization solver was adopted to solve the large scale optimization problem, and an alternating optimization strategy was implemented to solve the fluence intensity and aperture shapes simultaneously. Single arc comVMAT plans, utilizing 180 beams with 2. angular resolution, were generated for a glioblastoma multiforme case, a lung (LNG) case, and two head and neck cases-one with three PTVs (H&N-3PTV) and one with foue PTVs (H& N4PTV)-to test the efficacy. The plans were optimized using an alternating optimization strategy. The plans were compared against the clinical VMAT (clnVMAT) plans utilizing two overlapping coplanar arcs for treatment. Results: The optimization of the comVMAT plans had converged within 600 iterations of the block minimization algorithm. comVMAT plans were able to consistently reduce the dose to all organs-at-risk (OARs) as compared to the clnVMAT plans. On average, comVMAT plans reduced the max and mean OAR dose by 6.59% and 7.45%, respectively, of the prescription dose. Reductions in max dose and mean dose were as high as 14.5 Gy in the LNG case and 15.3 Gy in the H&N-3PTV case. PTV coverages measured by D95, D98, and D99 were within 0.25% of the prescription dose. By comprehensively optimizing all beams, the comVMAT optimizer gained the freedom to allow some selected beams to deliver higher intensities, yielding a dose distribution that resembles a static beam IMRT plan with beam orientation optimization. Conclusions: The novel nongreedy VMAT approach simultaneously optimizes all beams in an arc and then directly generates deliverable apertures. The single arc VMAT approach thus fully utilizes the digital Linac's capability in dose rate and gantry rotation speed modulation. In practice, the new single VMAT algorithm generates plans superior to existing VMAT algorithms utilizing two arcs. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:4263 / 4272
页数:10
相关论文
共 50 条
  • [1] Comprehensive Study of Parameters for Volumetric Modulated Arc Therapy (VMAT) Treatment Planning
    Talbert, C.
    Fontenot, J.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [2] Treatment planning for volumetric modulated arc therapy
    Bedford, James L.
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 5128 - 5138
  • [3] A Comprehensive Evaluation of Volumetric Modulated Arc Therapy (VMAT)
    Jang, S.
    Kuckarski, M.
    Pyakuryal, A.
    Sio, T.
    Hanley, J.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2897 - 2898
  • [4] Optimization approaches to volumetric modulated arc therapy planning
    Unkelbach, Jan
    Bortfeld, Thomas
    Craft, David
    Alber, Markus
    Bangert, Mark
    Bokrantz, Rasmus
    Chen, Danny
    Li, Ruijiang
    Xing, Lei
    Men, Chunhua
    Nill, Simeon
    Papp, David
    Romeijn, Edwin
    Salari, Ehsan
    [J]. MEDICAL PHYSICS, 2015, 42 (03) : 1367 - 1377
  • [5] Planning strategies in volumetric modulated arc therapy for breast
    Giorgia, Nicolini
    Antonella, Fogliata
    Alessandro, Clivio
    Eugenio, Vanetti
    Luca, Cozzi
    [J]. MEDICAL PHYSICS, 2011, 38 (07) : 4025 - 4031
  • [6] Automatic interactive optimization for volumetric modulated arc therapy planning
    Jim P Tol
    Max Dahele
    Jarkko Peltola
    Janne Nord
    Ben J Slotman
    Wilko FAR Verbakel
    [J]. Radiation Oncology, 10
  • [7] Volumetric modulated arc therapy planning for distal oesophageal malignancies
    Hawkins, M. A.
    Bedford, J. L.
    Warrington, A. P.
    Tait, D. M.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1009): : 44 - 52
  • [8] Automatic interactive optimization for volumetric modulated arc therapy planning
    Tol, Jim P.
    Dahele, Max
    Peltola, Jarkko
    Nord, Janne
    Slotman, Ben J.
    Verbakel, Wilko F. A. R.
    [J]. RADIATION ONCOLOGY, 2015, 10
  • [9] A Global Level Set Based Formulation for Volumetric Modulated Arc Therapy
    Nguyen, D.
    Lyu, Q.
    Ruan, D.
    O'Connor, D.
    Low, D.
    Sheng, K.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3690 - 3690
  • [10] Volumetric Modulated Arc Therapy
    Shepard, D.
    Popple, R.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)