Planning strategies in volumetric modulated arc therapy for breast

被引:50
|
作者
Giorgia, Nicolini [1 ]
Antonella, Fogliata [1 ]
Alessandro, Clivio [1 ]
Eugenio, Vanetti [1 ]
Luca, Cozzi [1 ]
机构
[1] Oncol Inst So Switzerland, Dept Radiat Oncol, Med Phys Unit, CH-6500 Bellinzona, Switzerland
关键词
progressive volumetric modulated arc therapy; breast skin-flash tool; RADIOTHERAPY; IMRT; PHOTON; CANCER; MOTION; IMPACT; TUMORS;
D O I
10.1118/1.3598442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not applicable with RapidArc volumetric modulated arc therapy not being based on a fixed field fluence delivery. In this study, a viable technical strategy to account for this need is presented. Methods: RapidArc (RA) plans for six breast cancer patients (three right and three left cases), were optimized (PRO version III) on the original CT data set (O) and on an alternative CT (E) generated with an artificial expansion (and assignment of soft-tissue equivalent HU) of 10 mm of the body in the breast region and of the PTV contours toward the external direction. Final dose calculations for the two set of plans were performed on the same original CT data set O, normalizing the dose prescription (50 Gy) to the target mean. In this way, two treatment plans on the same CT set O for each patient were obtained: the no action plan (OO) and the alternative plan based on an expanded optimization (EO). Fixing MU, these two plans were then recomputed on the expanded CT data set and on an intermediate one (with expansion = 5 mm), to mimic, possible changes in size due to edema during treatment or residual displacements due to breathing not properly controlled. Aim of the study was to quantify the robustness of this planning strategy on dose distributions when either the OO or the EO strategies were adopted. For all the combinations, a DVH analysis of all involved structures is reported. Results: I. The two optimization approaches gave comparable dose distributions on the original CT data set. II. When plans were evaluated on the expanded CTs (mimicking the presence of edema), the EO approach showed improved target coverage if compared to OO: on CT_10 mm, D-V = 98% [%] = 92.5 +/- 0.9 and 68.5 +/- 3.1, respectively, for EO and OO. Minor changes were registered in organs at risk sparing for both EO and OO. III. From dose distributions and DVHs, EO approach allowed to irradiate at near to prescription levels also the expanded fraction of the target: this would account also for residual intrafraction movements. Conclusions: The proposed plan strategy could represent a robust approach to account for moderate changes in target or body volume during the course of breast radiotherapy and to account for residual intrafractional respiratory motion in volumetric modulated arc therapy. The strategy, logistically simple to implement requiring only modifications to the standard planning workflow was routinely implemented at author's institute for treatment of breast patients with RapidArc. (C) 2011 American Association of Physicists in Medicine. [DOI:10.1118/1.3598442]
引用
收藏
页码:4025 / 4031
页数:7
相关论文
共 50 条
  • [1] Treatment planning for volumetric modulated arc therapy
    Bedford, James L.
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 5128 - 5138
  • [2] Optimization approaches to volumetric modulated arc therapy planning
    Unkelbach, Jan
    Bortfeld, Thomas
    Craft, David
    Alber, Markus
    Bangert, Mark
    Bokrantz, Rasmus
    Chen, Danny
    Li, Ruijiang
    Xing, Lei
    Men, Chunhua
    Nill, Simeon
    Papp, David
    Romeijn, Edwin
    Salari, Ehsan
    [J]. MEDICAL PHYSICS, 2015, 42 (03) : 1367 - 1377
  • [3] A comprehensive formulation for volumetric modulated arc therapy planning
    Nguyen, Dan
    Lyu, Qihui
    Ruan, Dan
    O'Connor, Daniel
    Low, Daniel A.
    Sheng, Ke
    [J]. MEDICAL PHYSICS, 2016, 43 (07) : 4263 - 4272
  • [4] Single-Arc Volumetric Modulated Arc Therapy Planning for Left Breast Cancer and Regional Nodes
    Sakumi, Akira
    Shiraishi, Kenshiro
    Onoe, Tsuyoshi
    Yamamoto, Kentaro
    Haga, Akihiro
    Yoda, Kiyoshi
    Ohtomo, Kuni
    Nakagawa, Keiichi
    [J]. JOURNAL OF RADIATION RESEARCH, 2012, 53 (01) : 151 - 153
  • [5] Knowledge-based volumetric modulated arc therapy treatment planning for breast cancer
    Apaza Blanco, Oscar
    Almada, Maria
    Garcia Andino, Albin
    Zunino, Silvia
    Venencia, Daniel
    [J]. JOURNAL OF MEDICAL PHYSICS, 2021, 46 (04) : 334 - 340
  • [6] Volumetric modulated arc therapy for advanced breast cancer
    Yu, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S185 - S185
  • [7] Automatic interactive optimization for volumetric modulated arc therapy planning
    Jim P Tol
    Max Dahele
    Jarkko Peltola
    Janne Nord
    Ben J Slotman
    Wilko FAR Verbakel
    [J]. Radiation Oncology, 10
  • [8] Volumetric modulated arc therapy planning for distal oesophageal malignancies
    Hawkins, M. A.
    Bedford, J. L.
    Warrington, A. P.
    Tait, D. M.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1009): : 44 - 52
  • [9] Automatic interactive optimization for volumetric modulated arc therapy planning
    Tol, Jim P.
    Dahele, Max
    Peltola, Jarkko
    Nord, Janne
    Slotman, Ben J.
    Verbakel, Wilko F. A. R.
    [J]. RADIATION ONCOLOGY, 2015, 10
  • [10] Hybrid volumetric modulated arc therapy for hypofractionated radiotherapy of breast cancer: a treatment planning study
    Alexander Venjakob
    Michael Oertel
    Dominik Alexander Hering
    Christos Moustakis
    Uwe Haverkamp
    Hans Theodor Eich
    [J]. Strahlentherapie und Onkologie, 2021, 197 : 296 - 307