A comprehensive formulation for volumetric modulated arc therapy planning

被引:17
|
作者
Nguyen, Dan [1 ]
Lyu, Qihui [1 ]
Ruan, Dan [1 ]
O'Connor, Daniel [1 ]
Low, Daniel A. [1 ]
Sheng, Ke [1 ]
机构
[1] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90024 USA
关键词
volumetric modulated arc therapy; non-greedy; non-heuristic; direct aperture optimization; DIRECT APERTURE OPTIMIZATION; RADIATION-THERAPY; SEQUENCING ALGORITHM; IMRT; VMAT; REGULARIZATION; SEGMENTATION; TOMOTHERAPY; DELIVERY;
D O I
10.1118/1.4953832
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Volumetric modulated arc therapy (VMAT) is a widely employed radiation therapy technique, showing comparable dosimetry to static beam intensity modulated radiation therapy (IMRT) with reduced monitor units and treatment time. However, the current VMAT optimization has various greedy heuristics employed for an empirical solution, which jeopardizes plan consistency and quality. The authors introduce a novel direct aperture optimization method for VMAT to overcome these limitations. Methods: The comprehensive VMAT (comVMAT) planning was formulated as an optimization problem with an L2-norm fidelity term to penalize the difference between the optimized dose and the prescribed dose, as well as an anisotropic total variation term to promote piecewise continuity in the fluence maps, preparing it for direct aperture optimization. A level set function was used to describe the aperture shapes and the difference between aperture shapes at adjacent angles was penalized to control MLC motion range. A proximal-class optimization solver was adopted to solve the large scale optimization problem, and an alternating optimization strategy was implemented to solve the fluence intensity and aperture shapes simultaneously. Single arc comVMAT plans, utilizing 180 beams with 2. angular resolution, were generated for a glioblastoma multiforme case, a lung (LNG) case, and two head and neck cases-one with three PTVs (H&N-3PTV) and one with foue PTVs (H& N4PTV)-to test the efficacy. The plans were optimized using an alternating optimization strategy. The plans were compared against the clinical VMAT (clnVMAT) plans utilizing two overlapping coplanar arcs for treatment. Results: The optimization of the comVMAT plans had converged within 600 iterations of the block minimization algorithm. comVMAT plans were able to consistently reduce the dose to all organs-at-risk (OARs) as compared to the clnVMAT plans. On average, comVMAT plans reduced the max and mean OAR dose by 6.59% and 7.45%, respectively, of the prescription dose. Reductions in max dose and mean dose were as high as 14.5 Gy in the LNG case and 15.3 Gy in the H&N-3PTV case. PTV coverages measured by D95, D98, and D99 were within 0.25% of the prescription dose. By comprehensively optimizing all beams, the comVMAT optimizer gained the freedom to allow some selected beams to deliver higher intensities, yielding a dose distribution that resembles a static beam IMRT plan with beam orientation optimization. Conclusions: The novel nongreedy VMAT approach simultaneously optimizes all beams in an arc and then directly generates deliverable apertures. The single arc VMAT approach thus fully utilizes the digital Linac's capability in dose rate and gantry rotation speed modulation. In practice, the new single VMAT algorithm generates plans superior to existing VMAT algorithms utilizing two arcs. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:4263 / 4272
页数:10
相关论文
共 50 条
  • [31] Volumetric Modulated Arc Therapy for Soft Tissue Sarcomas: a Planning Comparison Study
    Warren, M.
    Webster, G.
    Wylie, J.
    Choudhury, A.
    [J]. CLINICAL ONCOLOGY, 2011, 23 (03) : S57 - S57
  • [32] Automated volumetric modulated arc therapy planning for whole pelvic prostate radiotherapy
    Buschmann, Martin
    Sharfo, Abdul Wahab M.
    Penninkhof, Joan
    Seppenwoolde, Yvette
    Goldner, Gregor
    Georg, Dietmar
    Breedveld, Sebastiaan
    Heijmen, Ben J. M.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (04) : 333 - 342
  • [33] Mathematical models for optimal Volumetric Modulated Arc Therapy (VMAT) treatment planning
    Dursun, Pinar
    Taskin, Z. Caner
    Altinel, I. Kuban
    [J]. INTERNATIONAL CONFERENCE ON ENTERPRISE INFORMATION SYSTEMS/INTERNATIONAL CONFERENCE ON PROJECT MANAGEMENT/INTERNATIONAL CONFERENCE ON HEALTH AND SOCIAL CARE INFORMATION SYSTEMS AND TECHNOLOGIES, CENTERIS/PROJMAN / HCIST 2016, 2016, 100 : 644 - 651
  • [34] A class solution for volumetric-modulated arc therapy planning in postprostatectomy radiotherapy
    Forde, Elizabeth
    Bromley, Regina
    Kneebone, Andrew
    Eade, Thomas
    [J]. MEDICAL DOSIMETRY, 2014, 39 (03) : 261 - 265
  • [35] Automated volumetric modulated arc therapy treatment planning for stage III NSCLC
    Kusters, M.
    Creemers, I.
    Van Kollenburg, P.
    Bouwmans, L.
    Schinagl, D.
    Bussink, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S601 - S601
  • [36] Volumetric Modulated Arc Therapy for Advanced Pancreatic Cancer„Volumetric modulated arc therapy“ bei lokal fortgeschrittenem Pankreaskarzinom
    Wietse Eppinga
    Frank Lagerwaard
    Wilko Verbakel
    Ben Slotman
    Suresh Senan
    [J]. Strahlentherapie und Onkologie, 2010, 186 (7) : 382 - 387
  • [37] Single-Arc Volumetric Modulated Arc Therapy Planning for Left Breast Cancer and Regional Nodes
    Sakumi, Akira
    Shiraishi, Kenshiro
    Onoe, Tsuyoshi
    Yamamoto, Kentaro
    Haga, Akihiro
    Yoda, Kiyoshi
    Ohtomo, Kuni
    Nakagawa, Keiichi
    [J]. JOURNAL OF RADIATION RESEARCH, 2012, 53 (01) : 151 - 153
  • [38] Comparative planning of volumetric modulated arc therapy versus intensity modulated radiation therapy and proton beam therapy in anal cancer
    Hansen, J.
    Wilken, E.
    Petersen, J.
    Serup-Hansen, E.
    Spindler, K. -L.
    [J]. ANNALS OF ONCOLOGY, 2016, 27 : 62 - 62
  • [39] Planning and Delivery of Fully Dynamic Trajectory Modulated Arc Therapy On Pituitary Adenoma: Dosimetric Advantages Over Conventional Volumetric Modulated Arc Therapy
    Liang, J.
    Hristov, D.
    Otto, K.
    Kim, S.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3599 - 3599
  • [40] FusionArc optimization: A hybrid volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) planning strategy
    Matuszak, Martha M.
    Steers, Jennifer M.
    Long, Troy
    McShan, Daniel L.
    Fraass, Benedick A.
    Romeijn, H. Edwin
    Ten Haken, Randall K.
    [J]. MEDICAL PHYSICS, 2013, 40 (07)