Off-target-isocentric approach in non-coplanar Volumetric Modulated Arc Therapy (VMAT) planning for lung SBRT treatments

被引:0
|
作者
Kim, Sangroh [1 ,3 ]
Tseng, Tzu-Chi [2 ]
机构
[1] Genesis Med Ctr, Radiat Oncol, Davenport, IA USA
[2] Mt Sinai Hosp, Radiat Oncol, New York, NY USA
[3] Genesis Med Ctr, Dept Radiat Oncol, Davenport, IA 52804 USA
来源
JOURNAL OF RADIOSURGERY AND SBRT | 2015年 / 3卷 / 03期
关键词
3D conformal; off-target; non-coplanar; VMAT; SBRT; Lung cancer; hypofractionation;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Volumetric Modulated Arc Therapy (VMAT) has emerged as an efficient alternative to traditional three-dimensional (3D) non-coplanar conformal (3D-NC-C) beams for lung cancer stereotactic body radiotherapy (SBRT) because of its superior dosimetric properties and native ease in planning and treatment delivery. However, patient immobilization in lung SBRT often presents challenging geometrical clearance issues in the execution of large (in excess of 180 degrees) non-coplanar arcs. In this study, we present an off-target-isocentric, non-coplanar VMAT (OTI-NC-VMAT) technique that appears to be simple, dosimetrically robust and allows for ample patient/couch-gantry clearance. We compared this technique to a target-isocentric, non-coplanar VMAT (TI-NC-VMAT) technique and the 3D-NC-C beams for dosimetric evaluations. Methods: Nineteen lung cancer patients previously treated with 3D-NC-C SBRT technique at our institution were selected. For each patient, an OTI-NC-VMAT plan and TI-NC-VMAT plan were created and compared to the original 3D-NC-C treatment plan. All of the plans were created for the same prescription dose of 54 Gy total in 3 fractions, covering 95% of the planning target volume (PTV). Nine to ten non-coplanar beams were used for the 3D technique and three non-coplanar arcs were used in both the TI-NC-VMAT and OTI-NC-VMAT plans, with the couch set at +/- 20 degrees and 0 degrees, with each arc rotation in excess of 180 degrees. Progressive Resolution Optimizer (PRO) in Varian Eclipse version 11 was used for all of the treatment planning. Conformity Index (CI), conformity number (CN), gradient index (GI), maximum dose at 2 cm away from the PTV (D2cm), mean lung dose (MLD), V20, V5 and mean target dose (MTD) were analyzed for all of the plans. We also performed statistical analysis to examine differences in the dosimetric indices between 3D and VMAT techniques. Results: Dosimetric indices CI, CN, GI, V20 and MTD values were similar, within 5%, for all three plans: 3D-NC-C, TI-NC-VMAT and OTI-NC-VMAT. However, both types of VMAT plans were dosimetrically superior to 3D conformal plans in organ-at-risk (OAR) sparing; D2cm, MLD, and V5 values were significantly lower at 6-8%, 9-12% and 2630% in VMAT plans, respectively. The OTI-NC-VMAT plans showed equivalent plan quality to the TI-NC-VMAT plans and exhibited robust freedom from limiting arc rotation due to potential patient/couch-gantry collision. Conclusions: The OTI-NC-VMAT plans appear dosimetrically equivalent to TI-NC-VMAT plans for lung SBRT, while permitting large angle arc selection, free from obstructional limitations. Both OTI-NC-VMAT and TI-NC-VMAT plans were dosimetrically superior to 3D-NC-C plans in terms of organ-at-risk (OAR) sparing.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [1] Non-coplanar volumetric-modulated arc therapy (VMAT) for craniopharyngiomas reduces radiation doses to the bilateral hippocampus: a planning study comparing dynamic conformal arc therapy, coplanar VMAT, and non-coplanar VMAT
    Uto, Megumi
    Mizowaki, Takashi
    Ogura, Kengo
    Hiraoka, Masahiro
    [J]. RADIATION ONCOLOGY, 2016, 11
  • [2] Non-coplanar volumetric-modulated arc therapy (VMAT) for craniopharyngiomas reduces radiation doses to the bilateral hippocampus: a planning study comparing dynamic conformal arc therapy, coplanar VMAT, and non-coplanar VMAT
    Megumi Uto
    Takashi Mizowaki
    Kengo Ogura
    Masahiro Hiraoka
    [J]. Radiation Oncology, 11
  • [3] Automated Non-coplanar Volumetric Modulated Arc Therapy Planning for Maxillary Sinus Carcinoma
    Ohira, Shingo
    Inui, Shoki
    Kanayama, Naoyuki
    Ueda, Yoshihiro
    Miyazaki, Masayoshi
    Koizumi, Masahiko
    Konishi, Koji
    [J]. IN VIVO, 2023, 37 (01): : 417 - 423
  • [4] Dosimetric Evaluation of Non-Coplanar Arcs in VMAT Planning for SBRT Lung Cases: A Planning Study
    Lu, S.
    Gardner, S.
    Doemer, A.
    Chetty, I.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3407 - 3407
  • [5] Coplanar vs. Non-coplanar Intensity Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) Treatment Planning for Fronto-Temporal High Grade Glioma (HGG)
    Vlachaki, M. T.
    Panet-Raymond, V.
    Zavgorodni, S.
    Bendorffe, W.
    Nichol, A.
    Beckham, W.
    Truong, P. T.
    Ansbacher, W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S832 - S832
  • [6] Pattern of recurrence of glioblastoma treated with non-coplanar volumetric modulated arc therapy
    Georgiou, I.
    Bhatt, P.
    Bodkin, P.
    Giamouriadis, A.
    Ross, S.
    Walkden, J.
    Olson, S.
    Neelakantan, A.
    Torgersen, A.
    Whibley, M.
    Moleron, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S988 - S988
  • [7] Dosimetric Comparison of Coplanar Volumetric Modulated Arc Therapy and Non-coplanar Intensity Modulated Radiation Therapy for Pancreatic Cancer
    Badkul, R. K.
    Kile, L.
    Saleh, H.
    Chen, A. M.
    Lominska, C. E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E635 - E636
  • [8] Coplanar and non-coplanar VMAT facilitate OAR dose sparing in central lung SBRT
    Thomsen, J. B.
    Persson, G. F.
    Aznar, M. C.
    Berthelsen, A. K.
    Specht, L.
    Josipovic, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1021 - S1021
  • [9] A dosimetric comparison of isocentric and non-isocentric coplanar SBRT VMAT plans for peripheral lung tumours
    Conroy, L.
    Liu, H. W.
    Lau, H.
    Smith, W. L.
    [J]. MEDICAL PHYSICS, 2014, 41 (08) : 20 - 20
  • [10] STATIC COUCH NON-COPLANAR ARC SELETION OPTIMIZATION FOR LUNG SBRT TREATMENT PLANNING
    Lincoln, John
    MacDonald, Lee
    Syme, Alasdair
    Thomas, Christopher G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S124 - S124