Spiral scanning X-ray fluorescence computed tomography

被引:9
|
作者
de Jonge, Martin D. [1 ]
Kingston, Andrew M. [2 ]
Afshar, Nader [1 ]
Garrevoet, Jan [3 ]
Kirkham, Robin [4 ]
Ruben, Gary [1 ,5 ]
Myers, Glenn R. [2 ]
Latham, Shane J. [2 ]
Howard, Daryl L. [1 ]
Paterson, David J. [1 ]
Ryan, Christopher G. [4 ]
McColl, Gawain [6 ]
机构
[1] ANSTO, Australian Synchrotron, 800 Blackburn Rd, Clayton, Vic 3168, Australia
[2] Australian Natl Univ, Res Sch Phys & Engn, Dept Appl Math, Acton, ACT 2601, Australia
[3] Deutsches Elektronen Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany
[4] CSIRO Earth Sci & Res Engn, Clayton, Vic 3168, Australia
[5] Monash Univ, Sch Phys & Astron, Clayton, Vic 3800, Australia
[6] Florey Inst Neurosci & Mental Hlth, Parkville, Vic 3010, Australia
来源
OPTICS EXPRESS | 2017年 / 25卷 / 19期
关键词
CAENORHABDITIS-ELEGANS; RECONSTRUCTION; CHALLENGES; RESOLUTION; ALIGNMENT; ANGLE;
D O I
10.1364/OE.25.023424
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Scanning X-ray fluorescence tomography was once considered impractical due to prohibitive measurement time requirements but is now common for investigating metal distributions within small systems. A recent look-ahead to the possibilities of 4th-generation synchrotron light sources [ J. Synchrotron. Radiat. 21, 1031 (2014)] raised the possibility of a spiral-scanning measurement scheme where motion overheads are almost completely eliminated. Here we demonstrate the spiral scanning measurement and use Fourier ring correlation analysis to interrogate sources of resolution degradation. We develop an extension to the Fourier ring correlation formalism that enables the direct determination of the resolution from the measured sinogram data, greatly enhancing its power as a diagnostic tool for computed tomography. (C) 2017 Optical Society of America
引用
收藏
页码:23424 / 23436
页数:13
相关论文
共 50 条
  • [31] Reduced-scan schemes for X-ray fluorescence computed tomography
    La Riviere, Patrick J.
    Vargas, Phillip
    Newville, Matt
    Sutton, Stephen R.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2991 - +
  • [32] X-ray Fluorescence Computed Tomography with a Compton Camera for a Clinical Application
    Vernekohl, Don
    Ahmad, Moiz
    Chinn, Garry
    Xing, Lei
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [33] X-ray fluorescence computed tomography with absorption correction for biomedical samples
    Yang, Qun
    Deng, Biao
    Du, Guohao
    Xie, Honglan
    Zhou, Guangzhao
    Xiao, Tiqiao
    Xu, Hongjie
    [J]. X-RAY SPECTROMETRY, 2014, 43 (05) : 278 - 285
  • [34] Optimization of Detection Angle for Pinhole X-Ray Fluorescence Computed Tomography
    Guo Jing
    Feng Peng
    Deng Luzhen
    Luo Yan
    He Peng
    Wei Biao
    [J]. ACTA OPTICA SINICA, 2020, 40 (01)
  • [35] Reduced-scan schemes for x-ray fluorescence computed tomography
    La Riviere, Patrick J.
    Vargas, Phillip
    Newville, Matt
    Sutton, Stephen R.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1535 - 1542
  • [36] 7 years of X-Ray fluorescence computed micro-tomography
    Simionovici, A
    Golosio, B
    Chukalina, M
    Somogyi, A
    Lemelle, L
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 232 - 242
  • [37] Fluorescence X-ray Computed Tomography Using CdTe Detector Array
    Yoon, Changyeon
    Lee, Wonho
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [38] Optimized Detector Configuration for Polarized X-Ray Fluorescence Computed Tomography
    Vernekohl, D.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3019 - 3020
  • [39] Quantitative Reconstruction of Polychromatic X-ray Fluorescence Computed Tomography Using Transmission Tomography
    Gao, Bo
    Laforce, Brecht
    Vincze, Laszlo
    Van Hoorebeke, Luc
    Boone, Matthieu N.
    [J]. ANALYTICAL CHEMISTRY, 2021, 93 (04) : 2082 - 2089
  • [40] Industrial X-ray computed tomography
    Pechstein, Torsten
    [J]. TM-TECHNISCHES MESSEN, 2020, 87 (02) : 79 - 80