Spiral scanning X-ray fluorescence computed tomography

被引:9
|
作者
de Jonge, Martin D. [1 ]
Kingston, Andrew M. [2 ]
Afshar, Nader [1 ]
Garrevoet, Jan [3 ]
Kirkham, Robin [4 ]
Ruben, Gary [1 ,5 ]
Myers, Glenn R. [2 ]
Latham, Shane J. [2 ]
Howard, Daryl L. [1 ]
Paterson, David J. [1 ]
Ryan, Christopher G. [4 ]
McColl, Gawain [6 ]
机构
[1] ANSTO, Australian Synchrotron, 800 Blackburn Rd, Clayton, Vic 3168, Australia
[2] Australian Natl Univ, Res Sch Phys & Engn, Dept Appl Math, Acton, ACT 2601, Australia
[3] Deutsches Elektronen Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany
[4] CSIRO Earth Sci & Res Engn, Clayton, Vic 3168, Australia
[5] Monash Univ, Sch Phys & Astron, Clayton, Vic 3800, Australia
[6] Florey Inst Neurosci & Mental Hlth, Parkville, Vic 3010, Australia
来源
OPTICS EXPRESS | 2017年 / 25卷 / 19期
关键词
CAENORHABDITIS-ELEGANS; RECONSTRUCTION; CHALLENGES; RESOLUTION; ALIGNMENT; ANGLE;
D O I
10.1364/OE.25.023424
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Scanning X-ray fluorescence tomography was once considered impractical due to prohibitive measurement time requirements but is now common for investigating metal distributions within small systems. A recent look-ahead to the possibilities of 4th-generation synchrotron light sources [ J. Synchrotron. Radiat. 21, 1031 (2014)] raised the possibility of a spiral-scanning measurement scheme where motion overheads are almost completely eliminated. Here we demonstrate the spiral scanning measurement and use Fourier ring correlation analysis to interrogate sources of resolution degradation. We develop an extension to the Fourier ring correlation formalism that enables the direct determination of the resolution from the measured sinogram data, greatly enhancing its power as a diagnostic tool for computed tomography. (C) 2017 Optical Society of America
引用
收藏
页码:23424 / 23436
页数:13
相关论文
共 50 条
  • [21] X-ray fluorescence micro-tomography and laminography using an x-ray scanning microscope
    Watanabe, N.
    Hoshinol, M.
    Yamamoto, K.
    Aoki, S.
    Takeuchi, A.
    Suzuki, Y.
    [J]. 9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
  • [22] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    [J]. ELECTRONICS AND POWER, 1978, 24 (01): : 36 - 41
  • [23] X-ray computed tomography
    Kalender, Willi A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13): : R29 - R43
  • [24] X-ray computed tomography
    Withers, Philip J.
    Bouman, Charles
    Carmignato, Simone
    Cnudde, Veerle
    Grimaldi, David
    Hagen, Charlotte K.
    Maire, Eric
    Manley, Marena
    Du Plessis, Anton
    Stock, Stuart R.
    [J]. NATURE REVIEWS METHODS PRIMERS, 2021, 1 (01):
  • [25] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    [J]. ELECTRONICS AND POWER, 1978, 24 (03): : 181 - 181
  • [26] X-ray computed tomography
    [J]. Nature Reviews Methods Primers, 1
  • [27] Correlative single-cell hard X-ray computed tomography and X-ray fluorescence imaging
    Zihan Lin
    Xiao Zhang
    Purbasha Nandi
    Yuewei Lin
    Liguo Wang
    Yong S. Chu
    Timothy Paape
    Yang Yang
    Xianghui Xiao
    Qun Liu
    [J]. Communications Biology, 7
  • [28] X-ray Fluorescence Computed Tomography (XFCT) Imaging with a Superfine Pencil Beam X-ray Source
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    [J]. PHOTONICS, 2021, 8 (07)
  • [29] Correlative single-cell hard X-ray computed tomography and X-ray fluorescence imaging
    Lin, Zihan
    Zhang, Xiao
    Nandi, Purbasha
    Lin, Yuewei
    Wang, Liguo
    Chu, Yong S.
    Paape, Timothy
    Yang, Yang
    Xiao, Xianghui
    Liu, Qun
    [J]. COMMUNICATIONS BIOLOGY, 2024, 7 (01)
  • [30] A numismatic study of Roman coins through X-ray fluorescence and X-ray computed μ-tomography analysis
    Smeriglio, Andrea
    Filosa, Raffaele
    Crocco, Maria Caterina
    Formoso, Vincenzo
    Barberi, Riccardo Cristoforo
    Solano, Andrea
    Cerzoso, Maria
    Polosa, Annalisa
    Cerrone, Valerio
    Agostino, Raffaele Giuseppe
    [J]. ACTA IMEKO, 2023, 12 (04):